• 제목/요약/키워드: Error Measurement

검색결과 3,903건 처리시간 0.039초

강결합방식의 GPS/INS 시스템에 대한 측정치 시간지연 추정 연구 (A Study on the Measurement Time-Delay Estimation of Tightly-Coupled GPS/INS system)

  • 이윤선;이상정
    • 한국군사과학기술학회지
    • /
    • 제11권4호
    • /
    • pp.116-123
    • /
    • 2008
  • In this paper we study the performance of the measurement time-delay estimation of tightly-coupled GPS/INS(Global positioning system/Inertial Navigation system) system. Generally, the heading error estimation performance of loosely-coupled GPS/INS system using GPS's Navigation Solution is poor. In the case of tightly-coupled GPS/INS system using pseudo-range and pseudo-range rate, the heading error estimation performance is better. However, the time-delay error on the measurement(pseudo-range rate) make the heading error estimation performance degraded. So that, we propose the time-delay model on the measurement and compose the time-delay estimator. And we confirm that the heading error estimation performance in the case of measurement time-delay existence is similar with the case of no-delay by Monte-Carlo simulation.

표면 부착형 동기 전동기 벡터 제어에서의 외란 관측기 기반 전류 측정 오프셋 오차 보상 방법 (Disturbance Observer-based Current Measurement Offset Error Compensation in Vector-controlled SPMSM Drives)

  • 이상민;이기복
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.402-409
    • /
    • 2022
  • In vector-controlled drive systems, the current measurement offset error causes unwanted torque ripple, resulting in speed and torque control performance degradation. The current measurement offset error is caused by various factors, including thermal drift. This study proposes a simple DC offset error compensation method for a surface permanent magnet motor based on a disturbance observer. The disturbance observer is designed in the stationary reference frame. The proposed method uses only the measured current and machine parameters without additional hardware. The effect of parameter variations is analyzed, and the performance of the current measurement offset error compensation method is validated using simulation and experimental results.

3차원 안면자동인식기(3D-AFRA)의 Software 정밀도 검사 : 형상측정프로그램 오차분석 (A Software Error Examination of 3D Automatic Face Recognition Apparatus(3D-AFRA) : Measurement of Facial Figure Data)

  • 석재화;송정훈;김현진;유정희;곽창규;이준희;고병희;김종원;이의주
    • 사상체질의학회지
    • /
    • 제19권3호
    • /
    • pp.51-61
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Constitutions. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So We should examine the Measurement of Facial Figure data error of 3D Automatic Face Recognition Apparatus(3D-AFRA) in Software Error Analysis. 2. Methods We scanned face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And we measured lengths Between Facial Definition Parameters of facial figure data by Facial Measurement program. 2.1 Repeatability test We measured lengths Between Facial Definition Parameters of facial figure data restored by 3D-AFRA by Facial Measurement program 10 times. Then we compared 10 results each other for repeatability test. 2.2 Measurement error test We measured lengths Between Facial Definition Parameters of facial figure data by two different measurement program that are Facial Measurement program and Rapidform2006. At measuring lengths Between Facial Definition Parameters, we uses two measurement way. The one is straight line measurement, the other is curved line measurement. Then we compared results measured by Facial Measurement program with results measured by Rapidform2006. 3. Results and Conclusions In repeatability test, standard deviation of results is 0.084-0.450mm. And in straight line measurement error test, the average error 0.0582mm, and the maximum error was 0.28mm. In curved line measurement error test, the average error 0.413mm, and the maximum error was 1.53mm. In conclusion, we assessed that the accuracy and repeatability of Facial Measurement program is considerably good. From now on we complement accuracy of 3D-AFRA in Hardware and Software.

  • PDF

Statistical analysis of KNHANES data with measurement error models

  • Hwang, Jinseub
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권3호
    • /
    • pp.773-779
    • /
    • 2015
  • We study a statistical analysis about the fifth wave data of the Korea National Health and Nutrition Examination Survey based on linear regression models with measurement errors. The data is obtained from a national population-based complex survey. To demonstrate the availability of measurement error models, two results between the general linear regression model and measurement error model are compared based on the model selection criteria which are Akaike information criterion and Bayesian information criterion. For our study, we use the simulation extrapolation algorithm for measurement error model and the jackknife method for the estimation of standard errors.

Semiparametric Bayesian Estimation under Structural Measurement Error Model

  • Hwang, Jin-Seub;Kim, Dal-Ho
    • Communications for Statistical Applications and Methods
    • /
    • 제17권4호
    • /
    • pp.551-560
    • /
    • 2010
  • This paper considers a Bayesian approach to modeling a flexible regression function under structural measurement error model. The regression function is modeled based on semiparametric regression with penalized splines. Model fitting and parameter estimation are carried out in a hierarchical Bayesian framework using Markov chain Monte Carlo methodology. Their performances are compared with those of the estimators under structural measurement error model without a semiparametric component.

Semiparametric Bayesian estimation under functional measurement error model

  • Hwang, Jin-Seub;Kim, Dal-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권2호
    • /
    • pp.379-385
    • /
    • 2010
  • This paper considers Bayesian approach to modeling a flexible regression function under functional measurement error model. The regression function is modeled based on semiparametric regression with penalized splines. Model fitting and parameter estimation are carried out in a hierarchical Bayesian framework using Markov chain Monte Carlo methodology. Their performances are compared with those of the estimators under functional measurement error model without semiparametric component.

흡수용액의 In-line 농도측정을 위한 기초연구 (A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution)

  • 민병혁;황덕용;정시영;구기갑
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.

연소장내 화염계측 오차 평가 (Error Evaluation on Flame Measurement in Combustion Field)

  • 양영준;허태영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.167-169
    • /
    • 2014
  • Spray combustion has been used in many industrial fields, for instance, such as diesel engines, gas turbines and industrial furnaces, and furthermore various measurement techniques have been applied to elucidate the phenomenon of spray combustion. In order to measure simultaneously the droplet velocity and the droplet size of spray, Phase Doppler Anemometry (PDA) was frequently used in spray combustion. However, the measurement error is occurred due to existence of flame, which is considered as influencing the precision of measurement. Therefore, the purpose of this study is experimentally to conduct the systematic evaluation on the measurement error when PDA measurement is applied to combustion field.

  • PDF

위상도플러 유속계를 이용한 계측에 있어서의 화염에 기인한 오차의 평가 (The evaluation of error due to flame in the measurement using phase doppler anemometry)

  • 양영준
    • 센서학회지
    • /
    • 제14권5호
    • /
    • pp.313-321
    • /
    • 2005
  • Spray combustion has been used in many industrial fields, for instance, such as diesel engines, gas turbines and industrial furnaces, and furthermore various measurement techniques have been applied to elucidate the phenomenon of spray combustion. In order to measure simultaneously the droplet velocity and the droplet size of spray, phase doppler anemometry (PDA) was frequently used in spray combustion. However, the measurement error is occurred due to existence of flame, which is considered as influencing the precision of measurement. Therefore, the purpose of this study is experimentally to conduct the systematic evaluation on the measurement error when PDA measurement is applied to combustion field.

리니어 모터의 직각도 측정과 대각선 오차 보정에 관한 연구 (A study on the diagonal error compensation and squareness measurement of linear motor)

  • 김준현;이창우;송준엽
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.287-288
    • /
    • 2006
  • This paper introduces an approach of method to compensate accuracy error of diagonal direction. The measurement of squareness error is an important parameter in performance test of two axis Linear Motor and this exerts influence on accuracy error of diagonal test. However, previous knowledge management approaches are limited in deviation measurement of optical axis or restrictive elements of diagonal measurements using laser interferometer. But this proposed method calculated diagonal accuracy error which was occurred by squareness error and compensated squareness error using orthogonal correction method of PMAC. From this result, diagonal accuracy error is significantly reduced. This experimental results show that geometric error of squareness error is easily corrected by dynamic coordinate correction.

  • PDF