• 제목/요약/키워드: Equivalent Mechanical Property

검색결과 85건 처리시간 0.028초

XLPE 절연체의 등가 및 가변온도 가속열화실험을 통한 기계적 특성 비교 분석 (A Comparison Study on Mechanical Properties of XLPE Insulation Thermally Degraded at Equivalent and Variable Temperature Conditions)

  • 김태준;황재상;정성훈;김태영
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.73-77
    • /
    • 2022
  • Recently, as the number of years of operation has increased for more than 30 years, interest in evaluating the remaining life of major power facilities such as transformers and ultra-high voltage cables is increasing. In particular, the risk of failure is increasing because the underground transmission XLPE cable has been built since 1980 and has been operating in excess of 30 years of design life or close proximity. Therefore, it is necessary to develop an algorithm to evaluate the residual life of the XLPE cable considering the load to determine the risk of failure. Since load data is large amount of data, it is necessary to make the variable load information equivalent to the time unit first in order to calculate the remaining life of the system quickly. In overseas literature, transformers are reported to be standardized for variable load equivalent conversion formulas, but they have not been reported for ultra-high voltage cables. Therefore, in this paper, whether the equivalent conversion formula of a transformer can be applied to XLPE cables was reviewed through accelerated degradation tests under equivalent and variable temperature conditions, and considerations were studied when evaluating the remaining operating life of XLPE cables based on the experimental results.

유한요소해석을 이용한 다상의 초전도 코일에 대한 기계적 열적 등가 물성 (Equivalent Mechanical and Thermal Properties of Multiphase Superconducting Coil Using Finite Element Analysis)

  • 사정우;허남일;최창호;오영국;조승연;도철진;권면;이경수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.975-980
    • /
    • 2001
  • Like composite material. the coil winding pack of the KSTAR (Korea Superconducting Tokamak Advanced Research) consist of multiphase element such as metallic jacket material for protecting superconducting cable, vacuum pressurized imprepregnated (VPI) insulation, and corner roving filler. For jacket material, four CS (Central Solenoid) Coils, $5^{th}$ PF (Poloidal Field) Coil, and TF (Toroidal Field Coil) use Incoloy 908 and $6-7^{th}$ PF coil, Cold worked 316LN. In order to analyze the global behavior of large coil support structure with coil winding pack, it is required to replace the winding pack to monolithic matter with the equivalent mechanical properties, i.e. Young's moduli, shear moduli due to constraint of total nodes number and element numbers. In this study, Equivalent Young's moduli, shear moduli, Poisson's ratio, and thermal expansion coefficient were calculated for all coil winding pack using Finite Element Method.

  • PDF

Free Vibration Analysis of Perforated Plate Submerged in Fluid

  • Jhung, Myung-Jo;Jo, Jong-Chull;Jeong, Kyeong-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제20권9호
    • /
    • pp.1323-1338
    • /
    • 2006
  • An analytical method to estimate the coupled frequencies of the circular plate submerged in fluid is developed using the finite Fourier-Bessel series expansion and Rayleigh-Ritz method. To verify the validity of the analytical method developed, finite element method is used and the frequency comparisons between them are found to be in good agreement. For the perforated plate submerged in fluid, it is almost impossible to develop a finite element model due to the necessity of the fine meshing of the plate and the fluid at the same time. This necessitates the use of solid plate with equivalent material properties. Unfortunately the effective elastic constants suggested by the ASME code are found to be not valid for the modal analysis. Therefore in this study the equivalent material properties of perforated plate are suggested by performing several finite element analyses with respect to the ligament efficiencies.

Structural stability of fire-resistant steel (FR490) H-section columns at elevated temperatures

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • 제17권1호
    • /
    • pp.105-121
    • /
    • 2014
  • A fundamental limitation of steel structures is the decrease in their load-bearing capacity at high temperatures in fire situations such that structural members may require some additional treatment for fire resistance. In this regard, this paper evaluates the structural stability of fire-resistant steel, introduced in the late 1999s, through tensile coupon tests and proposes some experimental equations for the yield stress, the elastic modulus, and specific heat. The surface temperature, deflection, and maximum stress of fire-resistant steel H-section columns were calculated using their own mechanical and thermal properties. According to a comparison of mechanical properties between fire-resistant steel and Eurocode 3, the former outperformed the latter, and based on a comparison of structural performance between fire-resistant steel and ordinary structural steel of equivalent mechanical properties at room temperature, the former had greater structural stability than the latter through $900^{\circ}C$.

오스테나이트계 스테인리스강 모재 및 용접부의 인장특성과 내식성에 관한 연구 (A study on the tensile property and corrosion resistance of austenitic stainless base and weld metal)

  • 정호신;김조권;엄동석
    • Journal of Welding and Joining
    • /
    • 제14권4호
    • /
    • pp.71-78
    • /
    • 1996
  • The effect of chemical composition on mechanical properry and corrosion resistance of austenitic stainless steel was investigated. The main results obtained were as follows : 1. There was a linear relationship between the tensile strength of stainless steel and the $Cr_{eq}/Ni_{eq}$. The larger the $Cr_{eq}/Ni_{eq}$ was the higher the tensile strength of stainless steel. 2. There was a good correlationship between $Cr_{eq}/Ni_{eq}$ and intergranular, gerneral corrsion rate. 3. Intergranular corrosion rate decreased linearly with increasing Cr content. 4. General corrosion rate decreased linearly with increasing Ni content. 5. Logarithm corrosion rate of intergranular and general corrosion has a linear relationship with all of the factor of $Cr_{eq}/Ni_{eq}$, Cr and Ni content.

  • PDF

Equivalent linear and bounding analyses of bilinear hysteretic isolation systems

  • Wang, Shiang-Jung;Lee, Hsueh-Wen;Yu, Chung-Han;Yang, Cho-Yen;Lin, Wang-Chuen
    • Earthquakes and Structures
    • /
    • 제19권5호
    • /
    • pp.395-409
    • /
    • 2020
  • With verifications through many relevant researches in the past few decades, adopting the equivalent lateral force procedure for designing seismically isolated structures as a preliminary or even final design approach has become considerably mature and publicly acceptable, especially for seismic isolation systems that mechanically exhibit bilinear hysteretic behavior. During the design procedure, in addition to a given seismic demand, structural designers still need to previously determine three parameters, such as mechanical properties of seismic isolation systems or design parameters and performance indices of seismically isolated structures. However, an arbitrary or improper selection of given parameters might cause diverse or even unacceptable design results, thus troubling structural designers very much. In this study, first, based on the criterion that at least either two design parameters or two performance indices of seismically isolated structures are decided previously, the rationality and applicability of design results obtained from different conditions are examined. Moreover, to consider variations of design parameters of seismically isolated structures attributed to uncertainties of mechanical properties of seismic isolation systems, one of the conditions is adopted to perform bounding analysis for seismic isolation design. The analysis results indicate that with a reasonable equivalent damping ratio designed, considering a specific variation for two design parameters (the effective stiffness and equivalent damping ratio) could present more conservative bounding design results (in terms of isolation displacement and acceleration transmissibility) than considering the same variation but for two mechanical properties (the characteristic strength and post-yield stiffness).

등가강성모델을 활용한 힌지체결부 동특성 동정 (Dynamic Property Identification of Structural Systems with Hinge Joint Using Equivalent Stiffness)

  • 원준호;임체규;이두호;최주호
    • 대한기계학회논문집A
    • /
    • 제36권12호
    • /
    • pp.1635-1642
    • /
    • 2012
  • 어셈블리 시스템의 동적거동을 예측하기 위해서는 그 시스템의 체결에 사용된 조인트의 동특성을 정확히 아는 것이 중요하다. 그러나 이들 체결부의 동특성은 매우 큰 산포로 인하여 해석 또는 실험적인 방법으로 동특성을 동정하기 까다로우며, 때로는 불가능 한 경우도 있다. 체결부 동특성 동정 관련 선행 연구사례는 대부분이 실험과 해석을 연계한 방법이며, 그 대상은 볼트조인트에 국한되어 있다. 본 연구에서는 힌지조인트를 대상으로 체결부의 동특성을 동정하는 간단한 방법을 제시한다. 본 연구에서 제시하는 방법의 타당성을 입증하기 위해두 개의 빔이 힌지조인트에 연결된 체결구조물을 제작하여 주파수-응답 실험을 실시하고 그 결과를 제시된 방법의 결과와 비교/검증한다. 그리고 본 연구에서 제안하는 방법을 실제 자동차에 사용되고 있는 글로브박스(Glove Box)의 힌지조인트에 적용해 보았다.

유한요소해석을 이용한 방열용 Al-AlN 복합재의 제2상 분율에 따른 열-기계적 특성예측 (Predicting Thermo-mechanical Characteristics from the 2nd Phase Fraction of Al-AlN Composites for LED Heat Sinks with FEM)

  • 윤주일
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.137-142
    • /
    • 2018
  • With the development of the electronic-materials industry, multi-functional metal-composite materials with high thermal conductivity and low thermal expansion must be developed for high reliability and high life expectancy. This paper is a preliminary study on the manufacturing technology of gas reaction control composite material, focusing on the prediction of the equivalent thermal properties of Al-AlN composite materials. Numerical equivalent property values are obtained by using finite element analysis and compared with theoretical formulas. Al-AlN composite materials should become the optimal composite material when the proportion of the reinforcing phase is less than 0.5.

1-3형 압전복합재료 등가물성 직접 추출 기법의 정확도 분석 (Accuracy of a direct estimation method for equivalent material properties of 1-3 piezocomposites)

  • 노응휘;김동현;문형민;장우석;윤홍우;표성훈;김경섭;조요한
    • 한국음향학회지
    • /
    • 제42권5호
    • /
    • pp.377-387
    • /
    • 2023
  • 본 논문에서는 1-3형 압전복합재료를 단일상의 균질 압전매질로 모델링하기 위해 필요한 등가의 물성을 유한요소 해석으로 직접 추출하는 기법의 정확도를 다룬다. 직접 추출 기법은 압전재료의 전기적, 기계적 거동과 상호 간 커플링을 기술하는 구성방정식을 기반으로 물성 행렬의 개별 성분들을 직접적으로 산출하는 방법이다. 직접 추출에 사용되는 두 가지 구성방정식 조합 간의 정확도를 비교하기 위하여 단일 1-3형 압전복합재료 하이드로폰을 대상으로 등가물성과 수신감도를 산출하고 전체 영역에 대한 유한요소 해석 결과와 비교한다. 물성 추출의 정확도는 압전복합재료를 구성하는 폴리머의 탄성 특성과 밀접한 관련이 있음을 확인하고, 오차 원인을 분석하여 정확한 등가물성 산출을 위한 가이드라인을 제시한다. 압전복합재료 하이드로폰과 주변의 음향구조물을 포함하는 스테이브 규모에 대해서도 등가 모델링을 적용하여 추출된 물성의 정확도와 연산량 감소를 확인한다.

Vibration Analysis of HDD Actuator with Equivalent Finite Element Model of VCM Coil

  • Kim, Dong-Woohn;Lee, Jin-Koo;Park, No-Cheol;Park, Young-Pil
    • Journal of Mechanical Science and Technology
    • /
    • 제17권5호
    • /
    • pp.679-690
    • /
    • 2003
  • As the rate of increase in areal density of the HDD has accelerated, dynamic characteristics of the HDD actuator need to be improved with respect to the performance of the tracking servo and shock transmission. Therefore, it is important to analyze the vibration characteristic of the HDD actuator that consists of the VCM part, E-block and pivot bearing. In this paper, vibration modes of the HDD actuator are investigated the using finite element and experimental modal analyses methods. To develop a detailed finite element model, finite element models of each components of the actuator assembly are constructed and tuned to the results of the EMA. The VCM coil is modeled as an equivalent finite element model that has an orthotropic material property using auto-model updating program. Auto-model updating program with improved sensitivity based iterative method is applied to build a detailed finite element model using the result of the EMA. A detailed finite element model of the HDD actuator is then constructed and analyzed.