1 |
SBI (1976), Fire Engineering Design of Steel Structures", Lund, Sweden.
|
2 |
Somaini, D., Knobloch, M. and Fontama, M. (2012), "Buckling of steel columns in fire: non-linear behaviour and design proposal", Steel Construct., 5(3), 175-182.
DOI
|
3 |
Yang, K.C., Chen, S.J., Lin, C.C. and Lee, H.H. (2006), "Experimental study on local buckling of fire-resisting steel columns under fire load", J. Construct. Steel Res., 61(4), 553-565.
|
4 |
Yu, H., Burgess, I.W., Davison, J.B. and Plank, R.J. (2008), "Numerical simulation of bolted steel connections in fire using explicit dynamic analysis", J. Construct. Steel Res., 64(5), 515-525.
DOI
|
5 |
Zalok, E., Hadjisophocleous, G.V. and Mehaffey, J.R. (2009), "Fire loads in commercial premies", Fire Mater., 33(2), 63-78.
DOI
ScienceOn
|
6 |
Kelly, F.S. and Sha, W. (1999), "A comparison of the mechanical properties of fire-resistant and S275 structural steels", J. Construct. Steel Res., 50(3), 223-233.
DOI
ScienceOn
|
7 |
Kodur, V., Dwoikat, M. and Fike, R. (2010), "High-temperature properties of steel for fire resistance modelling of structures", J. Mater. Civil Eng., 22(5), 423-434.
DOI
ScienceOn
|
8 |
Korean Standard Association, KS D 0026 (2002), Method of Elevated Temperature Tensile Test for Steels and Heat-Resisting Alloys, Seoul, Korea.
|
9 |
Korean Standard Association, KS B 0802 (2003), Method of Tensile Test for Metallic Materials, Seoul, Korea.
|
10 |
Korean Standard Association, KS F 2257-7 (2005), Methods of Fire Resistance Test for Elements of Building Construction-Beam, Column, Seoul, Korea.
|
11 |
Kwon, I.K. (1997), "Evaluation on the mechanical properties of fire resistant steels at high temperature condition with manufacturing processes", J. Steel Construct., 19(2), 181-190.
|
12 |
Kwon, I.K. (2009), "Development of analytic program for calculation of fire resistant performance on steel structures", J. Regional Assoc. Architect. Inst. Korea, 11(3), 201-208.
|
13 |
Kwon, I.K. and Shin, S.G. (2011), "Evaluation of fire resistance using mechanical properties at high temperature for steel column made of rolled steels (SS400)", Korean J. Metals Mater., 49(9), 671-677.
|
14 |
Kwon, I.K. and Kwon, Y.B. (2012), "Determination of limiting temperatures for H-section and hollow section columns", Steel Compos. Struct., Int. J., 13(4), 309-325.
DOI
|
15 |
Muratov, A.N., Morozov, Y.D., Chevskaya, O.N. and Filippov, G.A. (2007), "Technology for the commercial production of fire-resistant steel for building structures", Metallugist, 51(7), 446-453.
DOI
|
16 |
Usmani, A., Roben, C. and Al-Remal, A. (2009), "A very simple method for assessing tall building safety in major fires", J. Steel Struct., 9(1), 17-28.
DOI
ScienceOn
|
17 |
European Committee for Standardisation (ECS), Eurocode 3 (1995), Design of Steel Structures Part 1.2: General Rules Structural Fire Design, Brussels, Belgium.
|
18 |
Sakumoto, Y., Yamaguchi, T., Okada, T., Yoshida, M., Tasaka, S. and Saito, H. (1994), "Fire resistance of fire-resistant steel columns", J. Struct. Eng., 120(4), 1103-1121.
DOI
ScienceOn
|
19 |
Chung, H.Y., Lee, C.H., Su, W.J. and Lin, R.Z. (2010), "Application of fire-resistant steel to beam-to-column moment connections at elevated temperatures", J. Construct. Steel Res., 66(2), 289-303.
DOI
ScienceOn
|