• 제목/요약/키워드: Equipment Reliability

검색결과 1,159건 처리시간 0.025초

소규모 플랜트 기자재의 고장밀도함수가 가용도에 미치는 영향 평가 (A Study on the Availability Evaluation with Failure Density Function of Equipment of Small-scale Plant)

  • 이홍철;황인주
    • 한국유체기계학회 논문집
    • /
    • 제19권3호
    • /
    • pp.33-36
    • /
    • 2016
  • The investigation on the verification of availability simulation for small-scale plant has been carried out. This study focuses on the availability variation induced by number of equipment and iteration with failure density function. The equipment classification of small-scale plant and failure type and the methodologies on Monte-Carlo simulation are established. The availability deviation with programs showed under Max. 1.7% for the case of normal function. This method could be used to availability evaluation of small-scale plant, but calibration of the failure density function is necessary for general application.

공기압을 이용한 패드 변압기 침수방지용 장치 개발에 관한 연구 (The Development of Flood Protection System for Pad Transformer using Pneumatic Pressure)

  • 김기현;이상익;배석명;정찬웅;이재용
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.90-94
    • /
    • 2009
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. For diminishing flood damage of electrical equipment in the root, flood protection system which is used the basic frame of Pad transformer is developed using pneumatic pressure. This system is established on pressure generator equipment and sensor of flooded level operates at flooding occurrence and is maintained a shutting tightly structure. The system is able to protect indraft water in Pad Transformer and supply the electricity at emergency(flooding). And we tested safety for insulation resistance at flooding and applying an electrical current. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation by setting an example.

신규노형 원전의 발전정지유발기기 선정을 위한 고장모드영향분석 (Failure Mode Effective Analysis for selection of Single Point Vulnerability in New type Nuclear Power Plant)

  • 현진우;염동운
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.31-36
    • /
    • 2014
  • For decreasing an unexpected shutdown of Nuclear Power Plants, Korea Hydro & Nuclear Power co.(KHNP) has developed Single Point Vulnerability(SPV) of NPPs since 2008. SPV is the equipment that cause reactor shutdown & turbine trip or more than 50% power rundown due to its malfunction. New type Nuclear Power Plants need to develop the SPV list, so performed the SPV selection for about 1 year. To develop this, Failure Mode Effect Analysis(FMEA) methods are used. As results of FMEA analysis, about 700 equipment are selected as SPV. Thereafter those are going to be applied to new type Nuclear Power Plants to enhance equipment reliability.

재래시장 전기안전 감시시스템 개발 (Development of Electrical Safety Monitoring System for Conventional Markets)

  • 이상익;김기현;배석명
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.552-556
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of conventional markets is introduced the electric safety monitoring system which is suitable in conventional markets. Investigate the actual conditions about electrical equipment of conventional markets, electrical safety monitoring system was constructed. Electrical safety monitoring system to verify the performance of the experiment was to build a test bed. Research results will be used with the data for the reliability security of the electric safe system operation which follows in the conventional markets actual proof equipment construction which will be advanced.

발전소 제어설비의 신뢰성 평가를 이용한 최적 개조방안 도출(보령화력 사례) (The study of retrofit method for the used control system of Power Plants to improve its reliability)

  • 신윤오;정창기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.737-739
    • /
    • 1999
  • All equipment generally has a specified design service life. As an equipment nears the end of its design service life, replacement must be considered. In some cases, it is possible and more economical to continue the usage of the existing equipment for a longer period. So, replacement should be carefully decided considering the feasibility and economic benefits of the existing equipments' life extension. In this paper, assessment procedure for deciding between life extension and replacement of the electronic control system is presented with an application example. In particular estimation of the electronic control system's remaining life is focused on.

  • PDF

다이나모 기반의 차량 제동력 검사장비 개발 연구 (Research on Development of Dynamo based Vehicle Brake force Inspection Equipment)

  • 임진우;이광희;김부현;이철희
    • 자동차안전학회지
    • /
    • 제9권4호
    • /
    • pp.20-25
    • /
    • 2017
  • Dynamo based vehicle inspection device is end of line device for automobile industry. The device is utilized as implementing vehicle functionality inspection such as brake force, cruise control, kick-down acceleration, CAN inspection. As dynamo based inspection device is broadly adopted in automobile industry, the dynamic study is required to verify the vehicle test equipment reliability. This research recommends appropriate dynamic brake force inspection procedure and theoretical background for developed equipment. Dynamic characteristic of brake force implementation to roller is simplified. With simplified characteristics, the indirect brake force measurement strategy is developed and adopted. Comparison of each brake force result, the appropriate brake force inspection criterion is given.

이온 가속기의 인젝터 전원 장치 및 제어 시스템 (Power Supply and Control System for Injector of Ion Accelerator)

  • 임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.544-549
    • /
    • 1997
  • Injector of high voltage or linear ion accelerator is intended to generate, extract and form beam of certain species with required parameters at the entrance of accelerating structure or, for low energy case, directly in the processing chamber (end station). Injector is the main part defining the ion accelerator performance and reliability. Its power supply and control system (PSCS) features are conditioned by placing the injector equipment at high voltage potential and by complexity of the plasma-beam load. The injector's PSCS should provide: - Transmission of electric power onto high voltage (h/v) terminal; - Obtaining of required output characteristics for injector equipment operation; - Transmission of the operational data and start/stop signals from h/v terminal to control cabinet; - Rremote control of injector; - Withstanding the high voltage breakdowns and X-ray radiation; - Compatibility with other equipment. The paper is concerned with analysis of injectors' PSCS structure and description of the system developed for 50 keV, 20 mA heavy ion injector.

  • PDF

시스템 가용도에 미치는 고장감지장치의 영향 (The Effect of Failure Detection Equipment on System Availability)

  • 나성룡;방성환
    • 응용통계연구
    • /
    • 제26권1호
    • /
    • pp.111-118
    • /
    • 2013
  • 이 논문에서는 고장감지장치(FDE)가 시스템 가용도에 미치는 영향을 연구한다. 주시스템(MS) 수리 도중에 고장이 발생한 FDE를 수리하기 위한 새로운 수리 정책을 고려한다. 이 논문의 주요 목적은 MS의 가용도를 계산하고 비교하는 데에 있다.

LCD 제조용 노광기에 사용되는 리니어 모터의 냉각조건에 대한 연구 (A Study on Cooling Conditions of a Linear Motor used in an Exposer for the Manufacturing LCD)

  • 양홍천;이영남;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제11권4호
    • /
    • pp.31-36
    • /
    • 2012
  • The high thrust of the linear motor in the exposer generates the high temperature heat by the friction and the electromagnetic forces on its coil. It can cause the thermal deformation and the accuracy of the equipment is finally decreased which has a bad effect on the productivity. In this research, the heat and flow on the linear motor of the exposer has been analyzed. The existing equipment is non-contact fluid refrigerant type. The numerical analysis data of the existing equipment have been acquired and the reliability of the data has been verified. The revised modeling for the next-generation is suggested for cooling the exposer effectively.

차량신호를 이용한 주요 전장품의 고장 분석 (Fault Analysis of Electric Equipment Using Vehicle Signal)

  • 한영재;김기환;김상수;이병석;정상훈;조병찬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1488-1494
    • /
    • 2006
  • The most important thing to secure safety and reliability of railway vehicles is to verify performance characteristics of equipments, and related companies or research institutes had many efforts to verify performances and functions of equipments synthetically and efficiently. KHST(Korean High Speed Train) has been developed by KRRI(Korea Railroad Research Institute). An electric railway system is composed of high-tech subsystems, among which main electric equipment such as transformers and converter are critical components determining the performance of rolling stock. We developed a measurement system for on-line test and evaluation of performances of KHST. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the measurement system. By using the system, fault diagnosis and performance evaluation of electric equipment in Korean High Speed Train was conducted during test running.

  • PDF