• Title/Summary/Keyword: Environmental smoke

Search Result 304, Processing Time 0.029 seconds

Urinary Exposure Levels of Cotinine and Influence Factors among Non-smokers in Korean Adults - Korean National Environmental Health Survey (2009-2017) - (우리나라 성인 중 비흡연자에 대한 코티닌 노출수준 및 영향요인 분석 - 국민환경보건 기초조사(2009-2017) 결과 -)

  • Jeon, Hye Li;Hong, Sooyeon;Joo, Youngkyung;Kwon, Young Min;Jung, Sun Kyoung;Lee, Chulwoo;Yu, Seung Do;Yoo, Jiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.214-223
    • /
    • 2020
  • Objectives: The aim of this study is to identify temporal trends in urinary cotinine levels and exposure factors among Non-smokers in Korean adults. Methods: Biological samples and questionnaire data were collected from representative Korean adults recruited in the Korean National Environmental Health Survey from 2009 to 2017. Multiple regression analysis was performed to determine the factors affecting urinary cotinine concentrations of non-smokers. Results: The urinary cotinine levels of Korean non-smokers decreased in Cycle 2 (1.04 ㎍/L, 2012-2014) compared to Cycle 1 (1.93 ㎍/L, 2009-2011) but increased slightly in Cycle 3 (1.37 ㎍/L, 2015-2017). Among the diverse variables, the main factors of cotinine exposure were secondhand smoke exposure and the presence of smokers in the family. Conclusions: The results of this study identified temporal trends in cotinine exposure among non-smokers in the Korean adult population. These findings will be used to develop further assessment and environmental health policies on secondhand smoke exposure.

Pilot Study for Difference of Secondhand Smoke Exposure at Smoking and Non-smoking Nightclubs (흡연과 금연 나이트클럽의 간접흡연 노출의 차이에 대한 탐색연구)

  • Guak, Sooyoung;Lee, Boram;Xu, Siyu;Lee, Kiyoung;Lee, Dohoon
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.1
    • /
    • pp.10-16
    • /
    • 2014
  • Objectives: This pilot study assessed secondhand smoke (SHS) exposure in smoking and non-smoking nightclubs in Seoul, Korea by measuring the concentration of particulate matter smaller than $2.5{\mu}m$ ($PM_{2.5}$). Methods: This comparative study was conducted in three nightclubs in Seoul. While one non-smoking nightclub was measured on weekdays and weekends, different smoking nightclubs were measured on weekdays and weekends. The concentration of $PM_{2.5}$ was observed using a real-time monitor over an average of three hours. The number of people in the clubs was also estimated. Settled dust was collected in a smoking and a non-smoking nightclub and analyzed for NNK concentration. Results: The $PM_{2.5}$ concentration in the smoking nightclubs was higher than those found in the non-smoking nightclub by 26 times on weekdays and three times on weekends. Indoor $PM_{2.5}$ concentration was correlated with the number of people in the smoking nightclubs. Relatively high $PM_{2.5}$ concentration was observed in the non-smoking nightclub on weekends. NNK concentration in the smoking nightclub was 7 times higer than in the non-smoking nightclub. Conclusion: Smoking in nightclubs caused high $PM_{2.5}$ concentration. Although the non-smoking nightclub had a lower $PM_{2.5}$ concentration, $PM_{2.5}$ concentration on weekends was higher due to the smoking room. Complete prohibition of smoking in nightclubs can protect patrons from secondhand smoke exposure.

Environmental Tobacco Smoke Exposure of Workers at Restaurants in Seoul Metropolitan City (서울시 일부 음식점 종업원의 간접흡연 노출량 측정)

  • 고영림;양원호;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.173-182
    • /
    • 2002
  • Exposure to environmental tobacco smoke(ETS) increases the risk of lung cancer and other diverse health effect for nonsmokers. Health risk assessment of nonsmokers related to ETS exposure requires large and exact data of ETS exposure to nonsmokers. This study presented the data of ETS exposure to workers at three category of restaurants(Korean restaurant, coffee shop, wine shop) in Seoul. Markers of ETS exposure measured in this study were area and personal NO$_2$, area and urine nicotine, area respiratory suspended particulate(RSP) and urine cotinine. The mean concentration of RSP and nicotine of all restaurant indoor samples was 177.8$\mu\textrm{g}$/㎥(range:75.3~317.0$\mu\textrm{g}$/㎥) and 7.8$\mu\textrm{g}$/㎥(range:0~57.3$\mu\textrm{g}$/㎥). The mean concentration of urine cotinine measured for the biomarker of ETS exposure was 77.3ng/mL(range:17.3~174.6ng/mL). In all measurements, the concentration of ETS markers at the wine shop was higher than those at other restaurants. The correlation coefficient among the ETS markers measured in the study was significant between area RSP and nicotine concentration and between area NO$_2$and nicotine concentration.

An Experimental Study on the Smoke Filtration System of Suction Type of Exhaustic Gas using Vaccum (부압을 이용한 배기 흡입형 매연여과장치에 대한 실험적 연구)

  • Lee, H.S.;Ki, S.W.;Koh, D.K.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.16-21
    • /
    • 2011
  • Over the past years, many research works have been carried out to investigate the factors which govern the performance of diesel engine. The air pollutant emission from the diesel engine is still a significant environmental concern in many countries. In the present study, new system of smoke filtration of diesel engine is proposed. This new system is using vacuum equipment and filter for capture smoke. To verification new system experiments are performed at diesel vehicle and engine dynamometer. As a result it is founded that smoke is decreased of 67% at vehicle test and decrease of 45.2% at full load condition of engine dynamometer test.

An Experimental Study on the Smoke Reduction System of the Exhaust Gas Suction Type (배기 흡입형 매연저감장치에 관한 실험적 연구)

  • Ki, Si-Woo;Choi, Sang-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.833-839
    • /
    • 2010
  • Over the past years, many research works have been carried out to investigate the factors which govern the performance of diesel engine. The air pollutant emission from the diesel engine is still a significant environmental concern in many countries. In the present study, new system of smoke reduction of diesel engine is proposed. This new system is using vacuum equipment for capture smoke. To confirm new system experiments were performed at engine dynamometer. As a result of this experiment, the smoke reduction of this system was identified.

A Study of Heat and Smoke Exhaust to Subway Tunnel Direction (지하철 터널부로의 열 및 연기배출에 관한 연구)

  • Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.1-8
    • /
    • 2004
  • This study aims to derive the operation method of a comprehensive ventilation system which is capable of providing passengers with safe exit paths from platforms in onboard fire situations. To accomplish this, the airflow distributions in subway platforms under 6 types of tunnel vent system were calculated in addition to having analyzed diffusion behaviors of smoke and heat exhaust in such states by performing 6 kinds of different ventilation scenarios in a 3-D Fire Dynamic Simulation (FDS) simulation model. In order to recommend the mechanical smoke exhaust operation mode, Subway Environmental Simulation(SES) is used to predict the airflow of the inlet and outlet tunnel for the subway station to clarify the safety evaluation fir the heat and smoke exhaust on subway fire events.

An Experimental Study of Smoke Reduction System using Vacuum (부압을 이용한 매연저감장치의 실험적 연구)

  • Ham, Sung-Hoon;Kwon, Young-Woong;Oh, Se-Hoon;Park, Sung-Cheon
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.714-718
    • /
    • 2009
  • Over the past years, many research works have been carried out to investigate the factors which govern the performance of diesel engine. The air pollutant emission from the diesel engine is still a significant environmental concern in many countries. In the present study, new system of smoke reduction of diesel engine is proposed. This new system is using vacuum equipment and filter included moisture for capture smoke. To verificate new system experiments were performed at diesel vehicle. As a result it is founded that smoke is decreased.

Realtime Smoke Detection using Hidden Markov Model and DWT (은닉마르코프모델과 DWT를 이용한 실시간 연기 검출)

  • Kim, Hyung-O
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.4
    • /
    • pp.343-350
    • /
    • 2016
  • In this paper, We proposed a realtime smoke detection using hidden markov model and DWT. The smoke type is not clear. The color of the smoke, form, spread direction, etc., are characterized by varying the environment. Therefore, smoke detection using specific information has a high error rate detection. Dynamic Object Detection was used a robust foreground extraction method to environmental changes. Smoke recognition is used to integrate the color, shape, DWT energy information of the detected object. The proposed method is a real-time processing by having the average processing speed of 30fps. The average detection time is about 7 seconds, it is possible to detect early rapid.

Trend of Environmental Qualification of Safety-Related Digital Equipment in Nuclear Power Plants (원자력발전소 안전 관련 디지털 기기의 내환경검증 (Environmental Qualification) 동향)

  • Jae Seung Ko;Sang Eun Kim;Sung-ryul Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.20 no.1
    • /
    • pp.7-15
    • /
    • 2024
  • Environmental qualification is required for safety related electrical equipment under harsh environments located in nuclear power plants according to 10 CFR 50.49 and RG 1.89. As analog technology has recently been replaced by digital technology, NRC established RG 1.209 as a regulatory guideline for environmental qualification of safety related computer-based I&C system located in mild environments, requiring evaluation for electromagnetic compatibility, smoke exposure and type test for actual service conditions such as temperature and humidity. In this paper, the trend of environmental qualification for digital equipment is analyzed by comparing the environmental qualification requirements between digital and analog equipment.

Characterization of Respirable Suspended Particles and Polycyclic Aromatic Hydrocarbons associated with Environmental Tobacco Smoke

  • Baek, Sung-Ok;Park, Jin-Soo;Kim, Mi-Hyun;Roger A, Jenkins
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.1-17
    • /
    • 2000
  • In this study, the concentrations of particulate organic constituents of environmental tobacco smoke(ETS) were determined using an environmental smog chamber, where ETS is the sole source of target compounds. ETS was generated in a 30 ㎥ environmental chamber by a number of different cigarettes, including the Kentucky 1R4F reference cigarette and eight commercial brands. A total of 12 experimental runs was conducted, and target analytes included a group of ETS markers both in vapor and particulate phase and a class of polycylic aromatic hydrocarbos(PAHs) associated with ETS particles. The mass concentrations of PAH in ETS particles were also determined. The average contents of benzo(a) pyrene and benzo(a) anthracene in ETS particles for the commercial brands were 12.8 and 21.5$\mu\textrm{g}$/g, respectively, There values are all somewhat higher than those determined previously by other studies. Results form the chamber study are further used to estimate the average and variability of cigarette yields for target compounds associated with ETS. Finally, ratios of RSP to the surrogate standards of UVPM, FPM and solanesol were calculated for each sample. The average conversion factors factors for the eight commercial brands were 7.3, 38, and 41 for UVPM, EPM, and solanesol, respectively. The UVPM and FPM factors are in good agreement with the recently published values. Whereas there might be a substantial difference in the solanesol content among cigarettes produced in different countries, the variability is somewhat greater than those of UVPM and FPM, Unfortunately, comparison of the PAH yield data from this study with literature values was complicated by a lack of consistency in cigarette smoke generating methodology. Validation of the PAH yields was also difficult due to a lack of information on the ETS related PAH in the literature. From and engineering viewpoint , however, these data on the cigarette yields of ETS components may still provide useful information to studies on the mathematical modeling of indoor air quality management regarding tobacco smoke as a source of interest, or to studies on the assessment of human exposure to ETS.

  • PDF