• Title/Summary/Keyword: Energy Consumption Efficiency

Search Result 1,782, Processing Time 0.031 seconds

Performance Analysis Based on RAU Selection and Cooperation in Distributed Antenna Systems

  • Wang, Gang;Meng, Chao;Heng, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.12
    • /
    • pp.5898-5916
    • /
    • 2018
  • In this paper, the downlink performance of multi-cell distributed antenna systems (DAS) with a single user in each cell is investigated. Assuming the channel state information is available at the transmitter, four transmission modes are formulated as combinations of remote antenna units (RAUs) selection and cooperative transmission, namely, non-cooperative transmission without RAU selection (NCT), cooperative transmission without RAU selection (CT), non-cooperative transmission with RAU selection (NCT_RAUS), and cooperative transmission with RAU selection (CT_RAUS). By using probability theory, the cumulative distribution function (CDF) of a user's signal to interference plus noise ratio (SINR) and the system ergodic capacity under the above four modes are determined, and their closed-form expressions are obtained. Furthermore, the system energy efficiency (EE) is studied by introducing a realistic power consumption model of DAS. An expression for determining EE is formulated, and the closed-form tradeoff relationship between spectral efficiency (SE) and EE is derived as well. Simulation results demonstrate their consistency with the theoretical analysis and reveal the factors constraining system EE, which provide a scientific basis for future design and optimization of DAS.

The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System

  • DEDE SAGSOZ, Yesim;YILMAZ, Alper Erdem;EKMEKYAPAR TORUN, Fatma;KOCADAGISTAN, Beyhan;KUL, Sinan
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.261-268
    • /
    • 2022
  • In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 μS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.

Research on a handwritten character recognition algorithm based on an extended nonlinear kernel residual network

  • Rao, Zheheng;Zeng, Chunyan;Wu, Minghu;Wang, Zhifeng;Zhao, Nan;Liu, Min;Wan, Xiangkui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.1
    • /
    • pp.413-435
    • /
    • 2018
  • Although the accuracy of handwritten character recognition based on deep networks has been shown to be superior to that of the traditional method, the use of an overly deep network significantly increases time consumption during parameter training. For this reason, this paper took the training time and recognition accuracy into consideration and proposed a novel handwritten character recognition algorithm with newly designed network structure, which is based on an extended nonlinear kernel residual network. This network is a non-extremely deep network, and its main design is as follows:(1) Design of an unsupervised apriori algorithm for intra-class clustering, making the subsequent network training more pertinent; (2) presentation of an intermediate convolution model with a pre-processed width level of 2;(3) presentation of a composite residual structure that designs a multi-level quick link; and (4) addition of a Dropout layer after the parameter optimization. The algorithm shows superior results on MNIST and SVHN dataset, which are two character benchmark recognition datasets, and achieves better recognition accuracy and higher recognition efficiency than other deep structures with the same number of layers.

A Study on Effect Analysis of Integrated Demand Management According to Energy System Management Model (Energy System Management 모형을 통한 통합 수요관리 효과분석에 관한 연구)

  • Kim, Yong-Ha;Jo, Hyeon-Mi;Kim, Young-Gil;Park, Hwa-Yong;Kim, Hyeong-Jung;Woo, Sung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1339-1346
    • /
    • 2011
  • This paper is developed to demand management scenario of energy consumption efficiency improvement, electricity generation efficiency improvement, network efficiency improvement, change of distribution ratio, movement of energy source, change of heating system, put of CHP to quantitatively assess to impact on energy use of demand management at the national level. This scenario can be applied Energy System Management model was developed based on Energy Balance Flow. In addition, effect analysis through built demand management scenario was quantitatively evaluated integrated demand management effectiveness of energy cost saving, CO2 emission reduction and energy savings of national level by calculating to primary energy source usage change in terms of integration demand management effect more often than not a single energy source separated electricity, heat and gas.

CSMA/CA based Transmission Scheme for QoS Assurance and Energy Efficiency of WPAN Systems (CSMA/CA 경쟁방식 기반의 WPAN 시스템을 위한 QoS 보장 및 에너지 효율적 전송방식)

  • Joo, Yang-Ick;Lee, Yeon-Woo;Jung, Min-A;Jang, Bong-Seog;Lee, Seong-Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3B
    • /
    • pp.135-143
    • /
    • 2008
  • In this paper, we propose a QoS guaranteed and energy-efficient transmission scheme for Wireless Personal Area Networks (WPANs), which operate in conjunction with contention-based access protocols such as CSMA/CA. Energy consumption is one of the most important issues in WPAN systems, because WPAN devices are often required to operate under limited battery capacity. Furthermore, if the WPAN adopts a contention-based medium access protocol, the energy consumption problem becomes even more critical due to the collisions caused by independent channel access trials. Therefore, in this paper, we propose an algorithm that selects the optimum fragment size, modulation level, and transmission power, in order to minimize the energy consumption and guaranteethe QoS (Quality of Service) requirements, simultaneously. Our simulation results show that the proposed algorithm has better performance than the previous ones.

Influence on the Thermal Environment by Change of Indoor-air Volume of Plastic Greenhouse with Hot Air Heating Systems (온풍난방을 채용한 3연동 플라스틱 하우스의 실내공기용적 변화가 하우스 온열환경에 미치는 영향)

  • Jeon, Sam-Chae;Li, Chang-Su;Na, Su-Yeun;Huh, Jong-Chul;Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • Relatively being economical in installation and easy in operation, hot-air heating system has been generally used in greenhouse for heating system regardless of high cost in maintenance and uneven distribution of air temperature. Therefore to overcome the disadvantages in maintenance and in distribution of air temperature and to improve efficiency of heating system, this experimental study is performed. This experimental study aims to improve the character of uneven temperature distribution in vertical direction and to reduce energy consumption for heating in a greenhouse. The experiment had been performed to investigate change of thermal environment and effects on reducing energy consumption for heating in greenhouse by additional surface insulation and reduction of indoor-air volume that come by installing transparent vinyl membranes with different height in each house. The results show that there is a wide difference in oil-energy consumption between houses according to condition of surface insulation and change of indoor-air volume. Furthermore, the results show that the efficiency of dual surface is higher than that of change of indoor-air volume in terms of energy saving.

Efficient Energy management through Relay-Transsmission and Cluster Division in Wireless Sensor Network (무선 센서네트워크에서 중계전송과 클러스터 분할법을 사용한 효율적인 에너지 관리)

  • Kim, Jae-Sueng;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.401-405
    • /
    • 2007
  • In sensor network, cluster based routing protocol about efficient energy usage method has researched variously. But existing cluster based routing protocol have problems. one of the problem is sensor nodes's imbalance energy consumption problem at cluster reconstruction. anther is non- connection problem between header node and spc node when they are far from each other, not properly connected. We propose cluster re-division and header node of multihop transmission method in this paper. The cluster re-division method is the method that re-divides existing routing protocol with the small-scale cluster and multihop transmission method is the method regarding the relay transmission between the header nodes. Through the simulation, the proposed routing mechanism shows more excellent than exiting routing protocol in balance energy consumption and energy efficiency.

  • PDF

Investigation, analysis and study for urban transit's driving energy efficiency (도시철도 운전에너지 효율화를 위한 조사 분석 연구)

  • Kim, Young-Kyu;Park, Se-Young;Park, Young-Seok;Chung, Il-Bong;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.612-618
    • /
    • 2009
  • Recently the roles of railways about the prevention of global warming caused by greenhouse gases and for low carbon green growth are larger than ever. And the railroad-related research institutions have been active in researching for energy conservation. Especially the urban railroad has been emerged as the best means of transportation compared to the general public transportation systems in punctuality, stability, ecology and etc. In operating the urban railroad system there are various ways for energy savings. In the larger category, One is the hardware aspect according to the structure of the vehicle and the development of control systems. The other is the software aspect which efficient train operation can be made through control of driving patterns and driving diagram. In this paper, there is sense to analyze the result in verifying expectation relation with variable and the use of electric power on this after selecting main variables that can influence to the energy of the train operation in the software aspect. First, after collecting the basic data related to operation(train speed, operating hours, power consumption, the position of stopping station, electrical power system etc.) and according to this, investigating the consumption of the energy of the operation, in the side of energy consumption deducing and analyzing problem, this will be found solutions.

  • PDF

Energy-Efficient Context Monitoring Methods for Android Devices (안드로이드 디바이스를 위한 에너지 효율적 컨텍스트 모니터링 기법)

  • Kim, Moon Kwon;Lee, Jae Yoo;Kim, Soo Dong
    • Journal of Software Engineering Society
    • /
    • v.26 no.3
    • /
    • pp.53-62
    • /
    • 2013
  • Along with increasing supplies of smart devices, a proliferation of context-aware applications is came. However, acquiring contexts through sensors requires considerable energy consumption. It has became big constraints on running many context-aware applications in mobile devices having limited battery capacity. Hence, energy-efficient methods for monitoring contexts are highly required. In this paper, we propose four context monitoring methods, analyse energy consumption in each method, and provide guidelines for applying the methods. It is effective to decrease energy consumption for monitoring contexts with applying the methods. To assess the proposed methods, we implement an application that is aware of a user's motion and show quantitative comparison between each of the methods.

  • PDF

The Reduction of Energy Consumption by the Exterior Horizontal Shading Device during Design for the Retrofit of Public Buildings (공공청사 리트로핏 설계 시 외부 수평 차양 장치에 따른 에너지 소비량 절감 방안)

  • Auh, Jin Sun;Jang, Ji-Hoon;Leigh, Seung-Bok;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.17 no.2
    • /
    • pp.29-34
    • /
    • 2017
  • Purpose: Recently, significant heat loss through the window takes place in buildings. Nevertheless, there exists little literature concerning the exterior horizontal shading devices and the design criteria are not clearly settled yet. Applying the exterior horizontal shading devices is more efficient as compared to the interior shading devices in that solar radiation can be directly blocked before passing through the window or the envelope. The purpose of this study is to reduce the internal load by designing the exterior horizontal shading devices and verify the degree of reduction in energy consumption. Method: This study aims to reduce energy consumption in cooling and heating through proposing proper length and shape of the exterior horizontal shading devices in public buildings. In the process, actual energy data and the Design Builder simulation program are utilized. In addition, economic aspect is considered to figure out the optimal length of the exterior horizontal shading devices that maximizes efficiency. Result: As a result, the proper length and shape of the exterior horizontal shading devices are provided as follows: 1) Energy consumption in cooling and heating is minimized when the exterior horizontal shading devices are designed as 0.5m*2. 2) Electricity bill is the lowest when the exterior horizontal shading devices are designed as 3.3m*2. The gap between maximum and minimum electricity bill is about 7.8~14%.