• Title/Summary/Keyword: Emergency power

Search Result 756, Processing Time 0.025 seconds

A Study on a Elevator Emergency Call Device System and Performance Evaluation based on ICT for Efficient Handling in Emergency Situation (위급상황 시 효율적인 대처를 위한 ICT 기반의 엘리베이터 비상통화장치 시스템 및 성능 비교 연구)

  • Jung, Se-Hoon;Park, Sung-Kyun;Park, Hong-Jun;So, Won-Ho;Park, Dong-Kook;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.449-459
    • /
    • 2015
  • A lot of people were trapped in elevators without power supply when BLACK-OUT situation occurred in 2011. The telephone network of control room connected to the elevators had problem operating poorly. In this paper we propose an ICT based elevator emergency call device prototype system and evaluate the performance of the system. The proposed system quickly responds in emergency situation to guarantee passenger safety. For the goal, firstly the system tries to connect to a control room. If it fails the system attempts to call numbers for emergency contact and a rescue team sequentially. The system is designed to quickly support emergency contact as well. Finally, the information of elevator failure is rapidly transferred to the failure process device by the proposed system.

The Influence of Resilience, Awareness of Patient Safety Management, and Proactive Behavior on Performance of Standard Precautions among Nurses Working in Emergency Department (응급실 간호사의 회복탄력성, 환자안전관리에 대한 인식, 선도적 행위가 표준주의 수행에 미치는 영향)

  • Cha, Un Gyeom;Jeong, Sun Young
    • Journal of Korean Clinical Nursing Research
    • /
    • v.30 no.2
    • /
    • pp.104-113
    • /
    • 2024
  • Purpose: This study investigated the correlations among resilience, the awareness of patient safety management, proactive behavior, and the performance of standard precautions among nurses working in the emergency department. Additionally, it aimed to identify the factors influencing the performance of standard precautions. Methods: Data were collected through a descriptive survey conducted between June 10 and July 9, 2023. The participants included 208 nurses working in the emergency department in Korea. The collected data were analyzed using SPSS/WINdows software version 29.0, based on the frequency, percentage, mean, standard deviation, t-test, one-way analysis of variance, Scheffé test, Pearson's correlation coefficients, and multiple regression. Results: The analysis based on the participants' general characteristics showed that performance of standard precautions varied significantly according to age (t=2.10, p=.036), size of the emergency department (F=7.46, p<.001), average number of patients treated per day while working in the past month (t=-3.88, p<.001) and standard precautions training experience (t=2.16, p=.032). The main factors influencing the performance of standard precautions among nurses working in the emergency department are awareness of patient safety management (β=.62, p<.001), resilience (β=.18, p=.042), and age (β=-.15, p=.007), with a total explanatory power of approximately 46.0%. Conclusion: It is necessary to establish programs and an effective education system to increase resilience and awareness in patient safety management to improve the performance of standard precautions among nurses working in the emergency department.

Bayes Estimate for the Reliability of Nuclear-Power Plant Emergency Diesel Generator (비상디젤발전기 신뢰도에 대한 베이즈추정)

  • 심규박;류부형
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.3
    • /
    • pp.108-118
    • /
    • 1997
  • A commercial nuclear power station contains at least two emergency diesel generates(EDG) to control the risk of severe core demage during the station blackout accidents. Therefore the reliability of the EDG's to start and load-run on demend must be maintained at a sufficiently high level. Until now, a simple assessment of start and load-run success rates was used to calculate the EDG's reliability. However, this method has been found to contain many defects. Recently, the work of Martz et al.(1996) proposed the use of the Bayes estimator to find the EDG's reliability. In this paper, we will propose confidence interval for the Bayes estimator, compare the above two methods and, using practical examples, illustrate why the Bayes estimator method is more reasonable in our situation.

  • PDF

Operating Vibration Reduction Effect Evaluation of EDG at the NPP Site (원자력발전소 비상디젤발전기의 가동중 진동저감 효과)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.111-118
    • /
    • 2006
  • The Emergency Diesel Generator(EDG) is a very important piece of equipment for the safety of a Nuclear Power Plant(NPP). In this study, the operating vibration or three kinds or EDG system was measured. The target EDG systems art Yonggwang 5 unit, Ulchin 2 unit and Ulchin 3 unit. The Yonggwang 5 and Ulchin 3 unit EDG system is the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of this measurement is for a verification of the vibration isolation effect according to the foundation system. As a result. it can he said that the spring and viscous damper system of the EDG performed well for the vibration isolation.

  • PDF

EXPERT SYSTEM FOR A NUCLEAR POWER PLANT ACCIDENT DIAGNOSIS USING A FUZZY INFERENCE METHOD

  • Lee, Mal-Rey;Oh, Jong-Chul
    • Journal of applied mathematics & informatics
    • /
    • v.8 no.2
    • /
    • pp.505-518
    • /
    • 2001
  • The huge and complicated plants such as nuclear power stations are likely to cause the operators to make mistakes due to a variety of inexplicable reasons and symptoms in case of emergency. That’s why the prevention system assisting the operators is being developed for. First of all. I suggest an improved fuzzy diagnosis. Secondly, I want to demonstrate that a classification system of nuclear plant’s accident investigating the causes of accidents foresees possible problems, and maintains the reliability of the diagnostic reports in spite of improper working in part. In the event of emergency in a nuclear plant, a lot of operational steps enable the operators to find out what caused the problems based on an emergent operating plan. Our system is able to classify their types within twenty to thirty seconds. As so, we expect the system to put down the accidents right after the rapid detection of the damage control-method concerned.

Optimization of Transient Stability Control Part-II: For Cases with Different Unstable Modes

  • Xue Yusheng;Li Wei;Hill David John
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.spc2
    • /
    • pp.341-345
    • /
    • 2005
  • Part-I of this two-part paper develops an optimal algorithm for transient stability control to coordinate the preventive actions and emergency actions for a subset of contingencies with an identical unstable mode. In this portion, several subsets of contingencies having dissimilar unstable modes are dealt with. Preventive actions benefiting a subset of contingencies may go against the stability of others, thus coordination among the optimal schemes for individual subsets is necessary. The coordination can be achieved by replacing some preventive actions with contingency-specified emergency actions. It is formulated as a classical model of economic dispatch with stability constraints and stability control costs. Such an optimal algorithm is proposed based on the algorithm in Part-I of the paper and is verified by simulations on a Chinese power system.

Synergy of monitoring and security

  • Casciati, Sara;Chen, Zhi Cong;Faravelli, Lucia;Vece, Michele
    • Smart Structures and Systems
    • /
    • v.17 no.5
    • /
    • pp.743-751
    • /
    • 2016
  • An ongoing research project is devoted to the design and implementation of a satellite based asset tracking for supporting emergency management in crisis operations. Due to the emergency environment, one has to rely on a low power consumption wireless communication. Therefore, the communication hardware and software must be designed to match requirements, which can only be foreseen at the level of more or less likely scenarios. The latter aspect suggests a deep use of a simulator (instead of a real network of sensors) to cover extreme situations. The former power consumption remark suggests the use of a minimal computer (Raspberry Pi) as data collector.

A Study on the Emergency Control Algorithm for Viability Crisis of Power System (계통사고시 장해 경감을 위한 긴급제어에 관한 연구)

  • Song, Kil-Yeong;Lee, Hee-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.129-132
    • /
    • 1987
  • This paper presents an emergency control algorithms for viability crisis following abnormal condition as well as a sudden major supply outage and line outage. The algorithm considers the effect of voltage-reactive power control for determining the load shedding quantities and generation reallocation. The problem is decomposed into a P-problem and a Q-problem. The former minimizes system frequency deviation from nominal value and the latter minimizes voltages violation of load buses. The optimization problem is solved by a reduced gradient technique which can handle a great number of inequality constraints very efficiently. It has been found that the use of the proposed algorithm for 6-Bus system restore the abnormal system during the viability crisis to the normal state.

  • PDF

Development of Digital controller for emergency power generating system Using Micro-Controller (마이크로컨트롤러를 이용한 비상발전계통의 제어장치 개발)

  • Jeong, Eull-Gi;Jeon, Hee-Jong;Shon, Jin-Geun;Na, Chae-Dong;Lee, Seong-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.100-102
    • /
    • 2001
  • This paper resents digital controller of emergency power generator system. The controller offers an integrated alternative for Genset control, metering and remote monitoring. Proposed controller used 80c196kc one chip microprocessor for digital control, it measures parameters of generator and provides output signals to control starting and stopping of generator. Additionally protection and alarm functions are considered to system stability. As almost parts of controller are embedded by digital microprocessor and FPGA techniques, the controller has a more flexible feature and an improvement of precision. The developed system has a big merit economically and is suitable for any kW size generator.

  • PDF

Waterhammer in Transmission Pumping Station with Ball Valve (볼밸브를 사용한 송수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Kim, Joum-Bea
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1697-1702
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure. the hydraulic transients occur as a result of the sudden change in velocity. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations. in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

  • PDF