• 제목/요약/키워드: Elimination capacity

검색결과 118건 처리시간 0.028초

황산화 균주가 부착된 다공성 세라믹 biofilter를 이용한 $H_2S$ 제거 (Removal of Hydrogen Sulfide Using Porous Ceramic Biofilter Inoculated with Sulfur Oxidizing Bacteria)

  • 박상진;조경숙
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.649-655
    • /
    • 1999
  • Biofiltration of polluted gas streams contained $H_2S$ was studied. The experiments were performed in a laboratory-scale reactor with a porous ceramic media inoculated with sulfur oxidizing bacterium, TAS which was isolated from activiated sludge. The concentration of $H_2S$ in the inlet gas varied from 109 to 3,841 ppm, at the various space velocities(SV) of 50 $h^{-1}$ to 250 $h^{-1}$. Various tests have been conducted to evaluate the effects of such parameters as pH, concentration of sulfate ion and retention time on the pressure drop and maximum elimination capacity. The removal efficiency of $H_2S$ decreased as the $H_2S$ concentration or gas velocity increased in the inlet gas. Pressure drop was insignificant in this system. The maximum elimination capacity could reach up to 16.35g-S/kg-dry packing material/day.

  • PDF

도시 물순환 건전화를 위한 빗물관리 계획요소 평가 (Assessment of Criteria for selecting Rainwater Management Strategies)

  • 이태구;한영해
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.9-17
    • /
    • 2010
  • The purpose of this study is to draw out objective bases for selecting various applicable facilities in case of the establishment of rainwater management strategies. To do so, sixteen facilities were selected from decentralized rainwater management systems that induce rainwater infiltration and detention as well as centralized end-of-pipe type infiltration and detention facilities in local areas. With these facilities, it attempted to evaluate them in terms of sustainability, pollutant elimination, flood control capacity and costs and subsequently analyzed correlations between each characteristic. The outcomes of the analysis were as follows: First was the analysis of characteristics between decentralized rainwater management systems and end-of-pipe rainwater management systems. From the decentralized rainwater management systems, the mulden-rigolen system and grass swale at street level had the highest in the total of the four items while the totals of the underground detention tank and temporary detention site were highest in end-of-pipe rainwater management systems. After analyzing the correlation between different types of facilities and each variable, it can be said that decentralized rainwater management systems have a higher correlation than end-of-pipe rainwater management systems in terms of sustainability whereas the latter are better in flood control capacity than the former. Second, the analysis of correlation in variables of each facility is as follows: first, there is a negative correlation between sustainability value and flood control capacity value; and there is a positive correlation between flood control capability and pollutants elimination. In addition, it revealed that the higher the flood control and pollutant elimination capability the higher the facility costs. Based on these assessments, it is possible to use them as objective selection criteria for facility application in case of site development project or complex plan.

Biofilter를 이용한 폐가스중의 styrene 제거

  • 강염석;황재웅;장석진;박성훈
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.394-397
    • /
    • 2000
  • Styrene을 제거하기 위한 biofilter가 연구되었다. 운전 초기에 활성슬러지를 접종함으로써 start-up 기간을 24시간으로 줄일 수 있었다. 운전중 질소원 고갈 현상이 발생하였고 첨가된 ammonium sulfate양에 따라 제거된 styrene의 양을 정량적으로 구하여 이것을 biofilter의 장기운전에 이용할 수 있었다. Styrene의 maximum elimination $capacity(EC_{max})$와 critical elimination $capacity(EC_{cr})$는 각각 4.8kg $C\;/m^3{cdot}day$, 1.248kg $C\;/m^3{cdot}day$이었으며 styrene 농도 400ppmv까지를 분해하는데 EBRT 1min으로 제거율 95% 이상을 달성할 수 있었다.

  • PDF

Styrene Degradation in a Polyurethane Biofilter Inoculated with Pseudomonas sp. IS-3

  • KIM JAISOO;RYU HEE WOOK;JUNG DONG JIN;LEE TAE HO;CHO KYUNG-SUK
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권6호
    • /
    • pp.1207-1213
    • /
    • 2005
  • In a search for bacteria capable of degrading styrene better than previously isolated strains, bacterium IS-3 was isolated from activated sludge and found to be most closely related to Pseudomonas sp. Styrene degradation by this strain was tested in liquid cultures and polyurethane-packed biofilters. In liquid cultures, the rate of styrene degradation by this bacterium increased from 24.93 to $76.53\;{\mu}mol\;g^{-1}\;DCW\;H^{-1}$ for an initial mass range from 8.7 to $34.8{\mu}mol$. The maximum styrene elimination capacity was 580-635 $g/m^{3}\cdot$h at a space velocity (SV) of 50-200/h. The critical elimination capacities guaranteeing $95\%$ removal of the input styrene were determined to be 635, 170, and 38 $g/m^{3}\cdot$h, respectively, at SVs of 50, 100, and 200/h. Kinetic analysis revealed that the maximum styrene elimination velocity ($V_{m}$) for this biofilter was 1,000 g/m$\cdot$h, and the saturation constant ($K_{m}$) was 454 ppmv. Together, these results suggest that a polyurethane biofilter containing Pseudomonas sp. IS-3 could have potential practical applications for the effective removal of styrene gas.

암모니아 함유 악취폐가스의 광촉매반응공정과 바이오필터로 구성된 하이브리드시스템 처리 (Treatment of Malodorous Waste Air Containing Ammonia Using Hybrid System Composed of Photocatalytic Reactor and Biofilter)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제51권2호
    • /
    • pp.272-278
    • /
    • 2013
  • 퇴비공장 또는 공공시설에서 발생되는 악취폐가스의 대표적인 제거대상 오염원인 암모니아를 포함한 악취폐가스를 처리하기 위하여 여러 운전 조건 하에서의 광촉매반응기와 바이오필터로 구성된 하이브리드시스템을 운전하였다. 암모니아 총 제거효율은 하이브리드시스템의 운전부하가 운전 단계별로 커졌음에도 불구하고 약 80%로 유지되었다. 광촉매반응기에서의 암모니아 제거효율은 광촉매반응기로의 암모니아 유입부하량이 증가함에 따라서 광촉매반응기의 암모니아 제거효율은 65%에서 약 22%로 감소하였다. 같은 암모니아 유입부하량일지라도 암모니아농도가 클 때보다 적은 경우에 광촉매반응기의 암모니아 제거효율이 상대적으로 높았다. 반면에 바이오필터의 경우는 운전 전반부에는 암모니아 처리효율이 현저하게 억제되었으나 광촉매반응기의 경우와 반대로 시간이 경과하면서 암모니아 유입부하량이 증가함에도 불구하고 바이오필터의 암모니아 제거효율은 지속적으로 약 78%까지 증가하여서 Lee 등의 연구결과에서의 암모니아 제거효율과 비슷하게 도달하였다. 광촉매반응기에 의한 최대 암모니아 제거용량($EC_{PR}$)은 약 16 g-N/$m^3$/h 이었고, 바이오필터에 의한 암모니아 제거용량($EC_{BF}$)은 운전 초기에 암모니아 총 부하가 작은 경우에는 암모니아 총 부하증가에 따른 $EC_{BF}$의 증가추세가 미약하였으나 운전 후반부에 암모니아 총 부하가 큰 경우에는 암모니아 총 부하증가에 따른 $EC_{BF}$의 증가추세가 급격하게 커졌다. 하이브리드시스템 운전 6단계에서 암모니아 총 부하가 약 80 g-N/$m^3$/h일 때에 광촉매반응기에서의 $EC_{PR}$은 약 16 g-N/$m^3$/h이었고, 2차 공정이고 주공정인 바이오필터에 걸리는 암모니아 부하는 나머지인 약 64 g-N/$m^3$/h이고 주공정인 바이오필터의 $EC_{BF}$은 약 48 g-N/$m^3$/h로 산출되었다. 이러한 바이오필터의 암모니아 제거용량은 Kim 등의 연구결과로서 최대 암모니아 제거용량인 1,200 g-N/$m^3$/day와 거의 비슷하였다.

A Power Regulation and Harmonic Current Elimination Approach for Parallel Multi-Inverter Supplying IPT Systems

  • Mai, Ruikun;Li, Yong;Lu, Liwen;He, Zhengyou
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1245-1255
    • /
    • 2016
  • The single resonant inverter is widely employed in typical inductive power transfer (IPT) systems to generate a high-frequency current in the primary side. However, the power capacity of a single resonant inverter is limited by the constraints of power electronic devices and the relevant cost. Consequently, IPT systems fail to meet high-power application requirements, such as those in rail applications. Total harmonic distortion (THD) may also violate the standard electromagnetic interference requirements with phase shift control under light load conditions. A power regulation approach with selective harmonic elimination is proposed on the basis of a parallel multi-inverter to upgrade the power levels of IPT systems and suppress THD under light load conditions by changing the output voltage pulse width and phase shift angle among parallel multi-inverters. The validity of the proposed control approach is verified by using a 1,412.3 W prototype system, which achieves a maximum transfer efficiency of 90.602%. Output power levels can be dramatically improved with the same semiconductor capacity, and distortion can be effectively suppressed under various load conditions.

황화수소와 암모니아를 함유한 악취폐가스의 세미파일럿 규모 바이오필터 처리: 2. 분리 미생물들을 접종한 담체를 충전한 바이오필터 운전 (Semi-pilot Scaled Biofilter Treatment of Malodorous Waste Air Containing Hydrogen Sulfide and Ammonia: 2. Performance of Biofilter Packed with Media Inoculated with a Consortium of Separated Microbes)

  • 임광희
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.240-246
    • /
    • 2014
  • 황화수소와 암모니아를 포함한 악취폐가스를 처리하기 위하여 여러 semi-pilot 바이오필터 운전 조건 하에서 Bacillus cereus DAH-1056과 Arthrobacter sp. KDE-0311를 고정한 semi-pilot 바이오필터 시스템을 운전하였다. Semi-pilot 바이오필터 운전조건에서 Thiobacillus sp. IW와 반송슬러지를 고정한 바이오필터의 황화수소 removal efficiency는 약 80%이었고 암모니아의 removal efficiency는 약 50% 정도이었던 반면에 Bacillus cereus DAH-1056과 Arthrobacter sp. KDE-0311를 고정한 본 연구에서 황화수소의 removal efficiency는 약 90%이었고 암모니아의 removal efficiency는 약 60% 정도이었다. 따라서 본 연구에서 Thiobacillus sp. IW와 반송슬러지를 고정한 semi-pilot 바이오필터의 경우를 기준으로 황화수소 및 암모니아의 removal efficiency가 각각 약 13% 및 20% 정도 제고되었다. 또한 본 연구에서는 암모니아의 최대 elimination capacity가 약 $35g/m^3/h$로서 Thiobacillus sp. IW와 반송슬러지를 고정한 semi-pilot 바이오필터의 경우보다 $3{\sim}5g/m^3/h$ 정도 제고되어 10~17% 더욱 높았다. 한편 본 연구의 황화수소의 최대 elimination capacity는 약 $63g/m^3/h$ 정도로 약 15% 증가하였다. 본 연구에서는 같은 inlet load의 황화수소라 할지라도 높은 농도의 황화수소가 낮은 농도의 황화수소보다 바이오필터의 암모니아 처리를 더 어렵게 하거나, 같은 inlet load의 암모니아라 할지라도 낮은 농도의 암모니아의 경우가 높은 농도의 암모니아보다 더 큰 removal efficiency와 elimination capacity를 갖는 것이 관찰되었다. 본 연구에서의 황화수소 최대처리용량은 황화수소와 암모니아를 동시처리 하였음에도 불구하고 황화수소만을 바이오필터로 처리한 선행연구에서의 황화수소 최대처리용량을 초과하거나 비슷하였다. 또한 본 연구에서는 바이오필터로 황화수소와 암모니아를 동시처리한 선행연구보다 더 높은 암모니아 제거용량을 보였다.

Effect of Biofilter Operation Parameters on Dimethyl Disulfide Removal : Loading, Time, and Concentration

  • Arpacioglu, Bora C.;Kim, Jo-Chun;Allen, Eric R.;Kim, Seoung-Hyun
    • 한국환경과학회지
    • /
    • 제11권8호
    • /
    • pp.783-791
    • /
    • 2002
  • A laboratory-scale dual-column biofilter system was used to study the biofiltration of dimethyl disulfide(DMDS). The biofiltration of DMDS was found to depend on the pollutant loadings rather than the inlet concentrations. It was estimated that the pollutant was only inhibitory to the operation of the biofilters at DMDS concentrations greater than 5500 ppmv A residence time of 30 seconds(120 m$^3$/m$^2$/h volumetric loading) was determined as appropriate for efficient operation(>90%). The maximum elimination capacity for both compost mixtures under the current experimental conditions was found to range from 7.5 to 10 g-DMDS/m$^3$/h. A lower DMDS maximum elimination capacity was exhibited under acidified conditions.

생물살수여과법을 이용한 공기중 VOC 및 H2S 제거 (Removal of VOCs and H2S from Waste Gas with Biotrickling Filter)

  • 김경옥;김용제;원양수
    • 공업화학
    • /
    • 제19권5호
    • /
    • pp.519-525
    • /
    • 2008
  • 생물살수여과법을 이용하여 대표적인 휘발성 유기물질인 toluene, styrene과 악취물질인 $H_2S$를 운전조건에 따른 제거 특성에 대해 실험적 고찰을 중심으로 진행하였다. $H_2S$ 제거 특성 고찰을 위한 autotroph과 mixotroph 조건하에서는 $H_2S$ 부하율이 낮은 조건($10g/m^3{\cdot}hr$)에서는 두 조건에서 모두 제거율이 99% 이상을 나타냈다. 부하율이 증가하면서 제거율이 감소하였으며, mixotroph 조건하에서 제거율이 다소 높았다. 방향족 휘발성 유기화합물질인 toluene과 styrene 농도변화에 따른 부하율과 제거용량 관계에서 toluene 부하율이 $40g/m^3{\cdot}hr$ 이하에서는 농도에 관계없이 제거율이 거의 99%를 나타내나 부하율이 증가함에 따라서 제거율은 감소하며 부하율이 증가해도 제거용량이 더 이상 증가하지 않는 최고제거용량을 나타내고 있으며 toluene 농도가 0.2, 0.5과 $1.0g/m^3$일 때 최고제거용량은 각각 40, 45, $60g/m^3{\cdot}hr$으로 나타내고 있다. toluene으로 순응된 살수여과탑에 styrene을 주입하여 순응시킨 후 styrene 제거 실험결과는 toluene 실험결과와 유사한 경향을 나타내었으나 전체적으로 제거효율이 낮게 나타났다. 순환살수액 유량 등의 적정 운전조건은 탑내 미생물의 활성도, 반응기 물리/화학적 특성에 따라 물질전달, 탑내 주입된 공기의 분배, 살수액 통과 경로, 미생물 분포도, 공극율 등에 따라 제거효율이 달라지므로 이를 고려한 적정 운전조건이 결정되어야 한다.

싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정 (Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load)

  • 박노중;정승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF