Visual quality enhancement of three-dimensional photon-counting integral imaging using background noise removal algorithm (배경 잡음 제거 알고리즘을 적용한 3차원 광자 계수 집적 영상의 화질 향상)

  • Cho, Ki-Ok;Kim, Young jun;Kim, Cheolsu;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1376-1382
    • /
    • 2016
  • In this paper, we present a visual quality enhancement technique for conventional three-dimensional (3D) photon counting integral imaging using background noise removal algorithm. Photon counting imaging can detect a few photons from desired objects and visualize them under severely photon-starved conditions such as low light level environment. However, when a lot of photons are generated from background, it is difficult to detect photons from desired objects. Thus, the visual quality of the reconstructed image may be degraded. Therefore, in this paper, we propose a new photon counting imaging method that removes unnecessary background noise and detects photons from only desired objects. In addition, integral imaging can be used to obtain 3D information and visualize the 3D image by statistical estimations such as maximum likelihood estimation. To prove and evaluate our proposed method, we implement the optical experiment and calculate mean square error.

Whether Pinhole Scan or Single Photon Emission Computed Tomography (SPECT) in the Diagnosis of Bone and Joint Diseases (골격계진단에 있어서 핀홀스캔의 우월성)

  • Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 1996
  • Since the publication of the first bone scintiscans in 1962 three decades have elapsed. The bone scan has made great strides during this period, becoming one of the most commonly used nuclear imaging tests. In spite of the progress, however, the specificity of bone scan has remained relatively low. As the result it is a common practice to seek additional information from radiograph, CT scan and MR image, which is euphemistically termed as "image fusion or co-location." The basic reason is the inapplicability of the classical piecemeal analysis to interpreting planar and SPECT bone scans. Such analysis has its base on the observation of elemental features of morphology, which include the size, shape, contour, location, topography and internal architecture. The physiochemical profile may well also be included. Understandably, however, the miniatured images of the planar bone scan cannot provide these features in acceptable detail and the same holds true even with SPECT Images which are but sliced views of the reconstructed planar scans. Fortunately pinhole scanning has the capacity to portray both the morphological and chemical profiles of bone and joint diseases in greater detail through true magnification. The magnitude of pinhole scan resolution is practically comparable to that of radiography as far as gross anatomy is concerned. Thus, we feel strongly that pinhole scanning is a potential breakthrough of the long-lamented low specificity of bone scan. This presentation will discuss the fun-damentals, advantages and disadvantages and the most recent advances of pinhole scanning. It high-lights the actual clinical applications of pinhole scanning in relation to the diagnosis of infective and inflammatory diseases of bone and joint.

  • PDF

Reconstructed image quality enhancement by an improved pickup model in computational integral imaging (컴퓨터 집적 영상 기술에서 픽업 모델 개선에 의한 복원 화질 개선 방법)

  • Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1598-1603
    • /
    • 2011
  • This paper describes an enhancement method for a computational pickup model. The conventional computational pickup model utilizes the ray-trace model and the pinhole model. The conventional model is very useful, however, it suffers from quality degradation of reconstructed images at long distances. To overcome the problem, we propose an accurate pickup model. The proposed model includes integration of the rays incoming to a sensor that generates a pixel, resulting in robustness on the Aliasing artifact. To show the effectiveness of the proposed method, experimental results are carried out. The results indicated that the proposed method is superior to the conventional method.

Image-Quality Enhancement for a Holographic Wavefront Color Printer by Adaptive SLM Partitioning

  • Hong, Sunghee;Stoykova, Elena;Kang, Hoonjong;Kim, Youngmin;Hong, Jisoo;Park, Joosup;Park, Kiheon
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.29-37
    • /
    • 2015
  • The wavefront printer records a volume-reflection hologram as a two-dimensional array of elemental holograms from computer-generated holograms (CGHs) displayed on a spatial light modulator (SLM). The wavefront coming from the object is extracted by filtering in the spatial-frequency domain. This paper presents a method to improve color reproduction in a wavefront printer with spatial division of exposures at primary colors, by adaptive partitioning of the SLM in accordance with the color content encoded in the input CGHs, and by the controllable change of exposure times for the recording of primary colors. The method is verified with a color wavefront printer with demagnification of the object beam. The quality of reconstruction achieved by the proposed method proves its efficiency in eliminating the stripe artifacts that are superimposed on reconstructed images in conventional mosaic recording.

Synthesis and Characterization of a $Di-{\mu}-oxo-bridged$ Molybdeum(V) Complexes (두 개 산소 가교형 몰리브덴(V)착물의 합성과 그 성질에 관한 연구)

  • Kim, Il-Chool;Kim, Yeoung-Chan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.205-210
    • /
    • 1999
  • The Mo(V) $di-{\mu}-oxo$ type $[Mo_2O_4(H_2O)_2L]Cl_2$ complexes(L: 4,4'-Diphenyl-2,2'-dipyridyl, 4,4'-Dimethyl-2,2'-dipyridyl, 4,7-Diphenyl-1,10-phenanthroline) have been prepared by the reaction of $[Mo_2O_4(H_2O)_6]^{2+}$ with a series of chelate ligands. These complexes are completed by two terminal oxygens arranged trans to one another and each ligand forms a chelate types. In $Mo_2O_4(H_2O)_2L$ two $H_2O$ coordinated at trans site of terminal oxgens. The prepared complexes have been characterized by elemental analysis, infrared spectra, electronic spectra, $^1H$ nuclear magnetic resonance spectra, and thermal analysis(TG-DTA). In the potential range -0.00V to -1.00V at scan rate of $50mVs^{-1}$, a cathodic peak at -0.83V ${\sim}$ -0.88V (vs SCE) and an anodic peak at -0.54V ${\sim}$ -0.88V (vs SCE) have been observed in aquous solution. The ratio of the cathodic to anodic current(Ipc/Ipa) is almost 2, we infer that redox is irreversible as dimer forms broken.

The analysis design and operating characteristics of VCM actuator for auto focusing (자동초점 조절용 VCM 액추에이터 구동특성 분석)

  • Park, J.M.;Lim, H.W.;Chae, B.;Kim, D.G.;Kim, P.H.;Cho, G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.447-448
    • /
    • 2007
  • Product development is consisting by trend that accommodate almost function digital cam in camera phone that can speak of Mobile appliance, and competition about number of elemental area of image sensor is consisting for market prior occupation between these. Propose in this research and small size camera phone self-focusing adjustment actuator that do city manufacture is similar with general storehouse pickup actuator drive way, but selected in cylindrical to reduce space that lens holder occupies because there is restriction loading of lens and space enemy. Target number of research established that execute drive displacement more than $600{\mu}m$ in 2.75V that is house voltage that is used in Mobile device that is general. Also, described about maximum transfer displacement characteristic, displacement response characteristic, hysteresis, response characteristic, smallest transfer step characteristic, actuator's drive characteristic that is manufactured to examination item of maximum consumption electric power by special quality estimation system that apply laser displacement sensor that produce itself to evaluate city manufactured actuator's special quality.

  • PDF

Structural Characterization of Bismuth Zinc Oxide Thin Films Grown by Plasma-Assisted Molecular Beam Epitaxy (플라즈마분자선에피탁시법으로 성장한 산화비스무스아연 박막의 구조특성)

  • Lim, Dong-Seok;Shin, Eun-Jung;Lim, Se-Hwan;Han, Seok-Kyu;Lee, Hyo-Sung;Hong, Soon-Ku;Joeng, Myoung-Ho;Lee, Jeong-Yong;Cho, Hyung-Koun;Yao, Takafumi
    • Korean Journal of Materials Research
    • /
    • v.21 no.10
    • /
    • pp.563-567
    • /
    • 2011
  • We report the structural characterization of $Bi_xZn_{1-x}O$ thin films grown on c-plane sapphire substrates by plasma-assisted molecular beam epitaxy. By increasing the Bi flux during the growth process, $Bi_xZn_{1-x}O$ thin films with various Bi contents (x = 0~13.17 atomic %) were prepared. X-ray diffraction (XRD) measurements revealed the formation of Bi-oxide phase in (Bi)ZnO after increasing the Bi content. However, it was impossible to determine whether the formed Bi-oxide phase was the monoclinic structure ${\alpha}-Bi_2O_3$ or the tetragonal structure ${\beta}-Bi_2O_3$ by means of XRD ${\theta}-2{\theta}$ measurements, as the observed diffraction peaks of the $2{\theta}$ value at ~28 were very close to reflection of the (012) plane for the monoclinic structure ${\alpha}-Bi_2O_3$ at 28.064 and the reflection of the (201) plane for the tetragonal structure ${\beta}-Bi_2O_3$ at 27.946. By means of transmission electron microscopy (TEM) using a diffraction pattern analysis and a high-resolution lattice image, it was finally determined as the monoclinic structure ${\alpha}-Bi_2O_3$ phase. To investigate the distribution of the Bi and Bi-oxide phases in BiZnO films, elemental mapping using energy dispersive spectroscopy equipped with TEM was performed. Considering both the XRD and the elemental mapping results, it was concluded that hexagonal-structure wurtzite $Bi_xZn_{1-x}O$ thin films were grown at a low Bi content (x = ~2.37 atomic %) without the formation of ${\alpha}-Bi_2O_3$. However, the increased Bi content (x = 4.63~13.17 atomic %) resulted in the formation of the ${\alpha}-Bi_2O_3$ phase in the wurtzite (Bi)ZnO matrix.

Characterization of coated colorless synthetic moissanite (코팅된 무색 합성 모이사나이트의 특징)

  • Choi, Hyunmin;Kim, Youngchool;Jang, Hansoo;Seok, Jeongwon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.1
    • /
    • pp.7-11
    • /
    • 2022
  • Recently, Hanmi Gemological Institute & Laboratory (HGI) had an opportunity to examine 5 transparent synthetic moissanite. The round brilliants ranged from 0.93 to 0.96 ct and had a colorless, pink, yellow, blue, and red color. Advanced testing results, including Fourier-transform infrared (FTIR) and Raman spectroscopy, identified all the specimens as synthetic moissanite. Under the microscope, all samples except the colorless were confirmed to be a synthetic moissanite coated with a colored film. EDXRF chemical analysis detected very weak X-ray fluorescence peak characteristics of Ca, Ti, and Co in the colored samples. These features were not detected in the colorless sample. Raman spectroscopy investigation was unable to detect the 1332 cm-1 (produced by sp3 bonding of carbon atoms) or the ~1550 cm-1 (produced by graphite-related sp2 bonding) peak in the colorless sample. The SEM image of the colorless sample showed no indication of a coating. The TEM image of the colorless sample revealed the presence of a 3~8 nm thick layer on the moissanite. Moreover, from the corresponding STEM Z-contrast image combined with the energy-dispersive X-ray spectroscopy (EDX) line profiles and EDX elemental maps, this layer was estimated to be carbon, silicon and oxygen.

Three-dimensional QR Code Using Integral Imaging (집적 영상을 활용한 3차원 QR code)

  • Kim, Youngjun;Cho, Ki-Ok;Han, Jaeseung;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2363-2369
    • /
    • 2016
  • In this paper, we propose three-dimensional (3D) quick-response (QR) code generation technique using passive 3D integral imaging and computational integral imaging reconstruction technique. In our proposed method, we divide 2D QR code into 4 planes with different reconstruction depths and then we generate 3D QR code using synthetic aperture integral imaging and computational reconstruction. In this 3D QR code generation process, we use integral imaging which is one of 3D imaging technologies. Finally, 3D QR code can be scanned by reconstructing and merging 3D QR codes at 4 different planes with computational reconstruction. Therefore, the security level for QR code scanning may be enhanced when QR code is scanned. To show that our proposed method can improve the security level for QR code scanning, in this paper, we carry out the optical experiments and computational reconstruction. In addition, we show that 3D QR code can be scanned when reconstruction depths are known.

Appearance Contamination of EPDM Article from Water Solution (EPDM 소재의 수용액으로부터의 외관 오염)

  • Choi, Sung-Seen;Chung, Hye-Seung;Joo, Yong-Tae;Yang, Kyung-Mo;Lee, Seong-Hoon
    • Elastomers and Composites
    • /
    • v.45 no.2
    • /
    • pp.100-105
    • /
    • 2010
  • An EPDM article was aged in air, distilled water, tap water, NaCl/$CaCl_2$ solution, and $CaCl_2/FeCl_3$ solution for 7 days. The aging temperature was $90^{\circ}C$. The samples aged in air and distilled water did not appear the whitening, those aged in tap water, NaCl/$CaCl_2$ solution, and $CaCl_2/FeCl_3$ solution showed the whitening. Soluble organic materials were analyzed using GC/MS to identify the whitening materials, surface morphology of the aged sample surface was examined using image analyzer and SEM, and elemental analysis of the materials accumulated on the sample surface was performed using EDX. Principal reason to cause whitening might be formation of metal salt of fatty acid by reaction between metal cation and fatty acid.