• Title/Summary/Keyword: Electronic monitoring

Search Result 1,283, Processing Time 0.027 seconds

Implementation of Real-Time Monitoring System for Overhead Contact Wire in Electric Railway (전차선로 검측을 위한 실시간 화상처리 시스템 구현)

  • Park, Young;Cho, Young-Hyeon;Lee, Ki-Won;Kwon, Sam-Young;Park, Hyun-Jun;Jang, Dong-Uk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.543-544
    • /
    • 2006
  • This paper describes a simple real-time monitoring system for use in measurement subsystem of contact wire and geometry of overhead contact wire in electric railway. The system has been consists of a high speed CMOS camera with resolution $1024\;{\times}\;1280$ pixels, line type laser source with a power equal to 300 mW, and PC-based image acquisition system with PCI Express slot. National instrument LabVIEW (8.0) and vision acquisition software have been used in application programming interface for image acquisition, display, and storage with a frequency of sampling of 500 acquisitions per second.

  • PDF

The Comparative Analysis of Water Quality Environment Data of Wando Onshore Seawater Farm and Tidal Observatory (완도 육상 해수 양식장과 조위관측소의 수질 환경 데이터 비교 분석)

  • Ye, Seoung-Bin;Kwon, In-Yeong;Kim, Tae-Ho;Park, Jeong-Seon;Han, Soon-Hee;Ceong, Hee-Taek
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.957-968
    • /
    • 2021
  • To improve the data on reliability of the onshore fish farm water quality monitoring system and operate the system efficiently, the water quality data of the onshore seawater fish farms which are progressing test operation, and the marine environmental information network(Wando tidal station) were compared and analyzed. Furthermore, data validation, data range filters, and data displacement checks were applied to analyze the data in a way that eliminates the data errors in water quality monitoring systems and increases the reliability of measurement data.

A Study on the Exploration Device of the Disaster Site Using Drones (드론을 이용한 재난 현장 탐사 장치에 대한 연구)

  • Nam, Kang-Hyun;Jang, Min-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.579-586
    • /
    • 2019
  • The purpose of this study is to determine the rapid saving of life through the drones when natural disasters such as earthquake and fire occur. Drones are equipped with riders, temperature, hazardous gas sensors and wireless cameras are registered with the application server for monitoring the disaster site and real-time monitoring functions are performed to identify the situation on site before rescuing personnel are active. When monitoring finds a person to save, the application server provides real-time image information for effective life-saving.

Ringing Frequency Extraction Method Based on EMD and FFT for Health Monitoring of Power Transistors

  • Ren, Lei;Gong, Chunying
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.307-315
    • /
    • 2019
  • Condition monitoring has been recognized as an effective and low-cost method to enhance the reliability and improve the maintainability of power electronic converters. In power electronic converters, high-frequency oscillation occurs during the switching transients of power transistors, which is known as ringing. The ringing frequency mainly depends on the values of the parasitic capacitance and stray inductance in the oscillation loop. Although circuit stray inductance is an important factor that leads to the ringing, it does not change with transistor aging. A shift in either the inside inductance or junction capacitance is an important failure precursor for power transistors. Therefore, ringing frequency can be used to monitor the health of power transistors. However, the switching actions of power transistors usually result in a dynamic behavior that can generate oscillation signals mixed with background noise, which makes it hard to directly extract the ringing frequency. A frequency extraction method based on empirical mode decomposition (EMD) and Fast Fourier transformation (FFT) is proposed in this paper. The proposed method is simple and has a high precision. Simulation results are given to verify the ringing analysis and experimental results are given to verify the effectiveness of the proposed method.

A Study on The Industrial Complex Disaster Surveillance and Monitoring System Using Drones (드론을 활용한 산업단지 재난감시 및 모니터링 시스템에 관한 연구)

  • Su-Ji Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.1
    • /
    • pp.233-240
    • /
    • 2024
  • In this study, we introduce a system for real-time monitoring of field conditions within an industrial complex using a 5G network UAV (: Unmanned Aerial Vehicle). When a monitoring event occurs in a sensor mounted on a UAV (detection of fire, harmful gas, or industrial disaster type human accident), key information from the sensor is transmitted to the UAS (: Unmanned Aerial System) application server. As a result of this information transmission and processing, managers or operators of the Industrial Complex Corporation were able to secure legal basis data for fatal accidents, fires, and detection of harmful gases at sites within the Industrial Complex Corporation through trigger processing for each accident risk situation.

Study on Optimal Welding Condition for Shipbuilding Steel Materials (조선강재의 최적 용접조건에 관한 연구)

  • Kim, Ok-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.128-133
    • /
    • 2011
  • In this study, the steel material for shipbuilding(LR-A class) was used, and FCAW was taken advantage of 3G attitude and they are welded by different welding ways. As a result of analyzing wave with welding monitoring system, the stable values are obtained which are the first floor(electronic current 164~182 A, voltage 24 V), the second floor(electronic current 174~190 A, voltage 22~25 V), the third floor(electronic current 158~188 A, voltage 22~25 V), and fourth floor(electronic current 172~184 A, voltage 22~25 V), at this time, the stable wave standard deviation and changing coefficient could be obtained. When the welding testing through nondestructive inspection was analyzed know defect of welding, there was no defect of welding in A, D, E, but some porosities in B, and slag conclusion near the surface in C, because the length of arc was not accurate, and the electronic current and voltage was not stable. After observing the change of heat affect zone through micro testing, each organization of floor formed as Grain Refinement, so welding part was fine, the distance of heat affect zone is getting wider up to change the values of the electronic current and voltage. As a result of degree of hardness testing, the hardness orders were the heat affect zone(HAZ), Welding Zone(WZ), and Base Metal(BM). When the distribution of degree of hardness is observed. B is the highest degree of hardness The reason why heat effect zone is higher than welding zone and base metal, welding zone is boiled over melting point($1539^{\circ}C$) and it starts to melt after the result of analysis through metal microscope, so we can know that delicate tissue is created at the welding zone. Therefore, in order to get the optimal conditions of the welding, the proper current of the welding and voltage is needed. Furthermore the precise work of welding is required.

On-Line Vibration Monitoring Techniques for Synchronous Generators by Flux Measurement (자속측정에 의한 동기발전기의 운전중 진동 감시기법)

  • Kim, Ji-Hyun;Hwang, Don-Ha;Chang, Ki-Chan;Kim, Yong-Joo;Kwon, Young-An;Song, Sang-Ock
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.952-954
    • /
    • 2002
  • The effort for measuring the rotor vibration caused by the short of rotor winding or air-gap eccentricity has been carried on. This paper introduces on-line vibration monitoring technologies using search coils to measure flux for synchronous generators. A 3,300/6,600 (V), 150 [kW] synchronous generator is built, and search coils are designed and inserted in the wedges. Furthermore, air-gap eccentricity is analyzed by finite element method and compared with experiment tests. Induced voltages caused by different air-gap eccentricity on the search coils are compared as well.

  • PDF

Development of Moving and Attaching Diagnosis Device Using IoT (IoT 활용 이동착탈식 열화 진단 장치 개발)

  • Ka, Chool-Hyun;Lee, Dong-Gyu;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.596-601
    • /
    • 2017
  • The advancement and diversification of urban functions has caused an increasing need to improve the reliability of power supplies. The diversification of urban areas causes social disruptions by paralyzing urban functions during power outages. A large power outage occurs in the event of an accident, owing to the subduction of distribution lines. Therefore, in recent years, for the sake of the environment and safety, the safety diagnosis of electric power facilities has become an important issue. In this system, because thermal information changes rapidly during unattended monitoring owing to heat concentration phenomenon due to abnormal load or deterioration, studies have been conducted on the development of a device that can notify the manager at all times.

Development of Electronic Power Monitoring System (전력 모니터링 시스템의 개발)

  • Park, S.J.;Yoon, J.G.;Kim, S.B.
    • Journal of Power System Engineering
    • /
    • v.7 no.1
    • /
    • pp.42-50
    • /
    • 2003
  • 최근의 배전반 설비의 고성능, 안정성, 신뢰성은 전기에너지의 사회적 욕구로 요구되고 있다. 본 논문에서는 전력품질에 관한 정보를 수집하고 통합 모니터링과 설비의 보호, 그리고 다양한 장치들을 제어할 수 있는 전력 모니터링 시스템의 개발에 대하여 고려하고자 한다. 전력품질 모니터링을 통하여 수집된 정보는 시스템의 효과적인 운용과 사용상의 신뢰성을 개선시킨다. 본 시스템은 크게 하드웨어부와 소프트웨어부로 구성된다. 하드웨어부는 원칩 마이크로 프로세서(Intel 80C196KC)를 사용한 측정과 제어, 통신 그리고 입/출력을 담당하는 다기능 인디케이터와 컨트롤러로 구성된다. 다양한 기능의 모니터링, 데이터베이스와 제어를 PC상에서 구현하기 위한 소프트웨어부는 사용자 그래픽 인터페이스(GUI) 기반의 비주얼 프로그래밍을 사용하여 개발되었다.

  • PDF

Wireless Sensor for Diagnostics of Electric Equipments (전력 설비 감시를 위한 무선 센서)

  • Choi, Yong-Sung;Kim, Hyung-Gon;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.98-102
    • /
    • 2008
  • Methods and analysis of a simple wireless sensor concept for detecting and locating faults as well as for load monitoring are presented. The concept is based on distributed wireless sensors that are attached to the incoming and outgoing power lines of secondary substations. A sensor measures only phase current characteristics of the wire it is attached to, is not synchronized to other sensors and does not need configuration of triggering levels. The main novelty of the concept is in detecting and locating faults by combining power distribution network characteristics on system level with low power sampling methods for individual sensors. This concept enables the sensor design to be simple, energy efficient and thus applicable in new installations and for retrofit purposes in both overhead and underground electrical distribution systems.

  • PDF