• Title/Summary/Keyword: Electronic devices

Search Result 4,580, Processing Time 0.038 seconds

MoOx/Si Heterojunction for High-Performing Photodetector (MoOx 기반 실리콘 이종접합 고성능 광검출기)

  • Park, Wang-Hee;Kim, Joondong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.11
    • /
    • pp.720-724
    • /
    • 2016
  • Transparent n-type metal-oxide semiconductor of $MoO_x$ was applied on a p-type Si substrate for high-performing heterojunction photodetector. The formation of $MoO_x$ on Si spontaneously established a rectifying current flow with a high rectification ratio of 1,252.3%. Under light illumination condition, n-type $MoO_x$/p-type Si heterojunction device provided significantly fast responses (rise time : 61.28 ms, fall time : 66.26 ms). This transparent metal-oxide layer ($MoO_x$) would provide a functional route for various photoelectric devices, including photodetectors and solar cells.

Analysis of Electrical Characteristics of Shield Gate Power MOSFET for Low on Resistance (차폐형 게이트 구조를 갖는 전력 MOSFET의 전기적 특성 분석에 관한 연구)

  • Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.2
    • /
    • pp.63-66
    • /
    • 2017
  • This research was about shielded trench gate power MOSFET for low voltage and high speed. We used T-CAD tool and carried out process and device simulation for exracting design and process parameters. The exracted parameters was used to design shieled and conventional trench gate power MOSFET. And The electrical characteristics of shieled and conventional trench gate power MOSFET were compared and analyzed for their power device applications. As a result of analyzing electrical characteristics, the recorded breakdown voltages of both devices were around 120 V. The electric distributions of shielded and conventional trench gate power MOSFET was different. But due to the low voltage level, the breakdown voltage was almost same. And the other hand, the threshold voltage characteristics of shielded trench gate power MOSFET was superior to convention trench gate power MOSFET. In terms of on resistance characteristics, we obtained optimal oxied thickness of $3{\mu}m$.

Coordinate Measurement in Wired Tablet Using a Electromagnetic Induction System (전자기유도기술을 이용한 유선 태블릿 좌표 측정)

  • Hong, Dong-Goo;Ryu, Young-Kee
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1099-1100
    • /
    • 2008
  • In this paper, we would like to introduce a simple and low cost wired pointing device by using a electromagnetic induction. A number of patents of Wacom describe electronic drawing devices or styluses. The movement of the stylus over a tablet is traced electronically and used applied to a resonant circuit in the stylus. Electromagnetic radiation emitted by the resonant circuit is detected by a sensing mechanism and location processing is used to locate the stylus. In this research, difference coil principle is used to detect the emitted radiation of the resonant circuit in the pen. This detection device shows good performance to detect the location of the pen on the tablet.

  • PDF

Measurement of Noise and Speed in the EMR using Power Line Network

  • Song, Yong-soo;Yoon, Sung-Won;Cho, Young-Bin;Lee, Chung-Keun;Min, Se-Dong;Nam SuK Bang;Lee, Myung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.58-58
    • /
    • 2002
  • Recently Many technologies of the P.L.N (Power Line Network) are introduced for an efficient communication. P.L.N transmits information using power line channel. A medical information transmission system is proposed in this paper for the effective transmission. The Power Line Networks have an advantage in low cost because it uses existent power line. It can be easily applied anywhere that a power line socket is available. But the power line channel is very noisy, because many electronic devices in generate electronic noise in modulated signals. This problem should be considered carefully in the design of medical information transmission system using P.L.N. The proposed system can be applied...I propose a telemedicine system using the power line network.

  • PDF

Effect of the size of active device and heatsink of power MOSFETs on its the junction to ambient transient thermal behavior

  • Koh, Jeong-Wook;An, Chul
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.241-244
    • /
    • 2000
  • To investigate the compact effect of the different area of an active layer and the different type of heatsink on the junction to ambient transient thermal impedance, we have characterized the thermal behavior of power MOSFETs that have three different areas of an active layer and two types of heatsink. To do so, the "cooling curve method" has been used in order to measure the junction-to-ambient transient thermal impedance Zthja that represents the thermal behavior of the devices. The measured data depiets that the larger area of an active layer gives the better-in other words. smaller-thermal impedance, and that the larger size of a heatsink improves the thermal impedance.

  • PDF

Development of Micro Cooling System for Telecommunication System using Oscillating Heat Pipe (진동 세관형 히트파이프를 이용한 통신 기기용 마이크로 냉각시스템의 개발)

  • Ha, Soo-Jung;Bae, Nae-Soo;Park, Chul-Min;Kim, Jung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1499-1505
    • /
    • 2003
  • Rapid development of electronic technology requires small size, high density packaging and high power of electronic devices. So, in this paper, characteristics on oscillating heat pipe according to operating conditions(environment temperature, charging ratio of working fluid, inclination) based on experimental study was investigated. From the experimental results, $25^{\circ}C$environment temperature), R-141b(working fluid)40%(charging ratio) was best performace at others of inclination angle and The top heating mode of OCHP performed 80% efficiency of the bottom heating mode.

  • PDF

An Experimental Study on Heat Transfer Performances in 8mm-diameter Heat Pipes with Screen Mesh Wick (스크린 메쉬 윅을 삽입한 8mm 히트파이프에서 열전달 성능에 관한 실험적 연구)

  • Park, Ki-Ho;Lee, Ki-Woo;Noh, Seung-Yong;Lee, Kye-Jung;Yoo, Seong-Yeon
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.48-53
    • /
    • 2001
  • This experimental study is to research heat transfer characteristics in copper-water heat pipes with screen wick, the 150 and 200-mesh. Recent advances in the miniaturization and large capacity of electronic devices have had a major impact on the design of electronic equipment. As a result, a high-performance cooling system is needed. Experimental variables are inclination angle, number of layer and temperature of cooling water. The distilled water was used for the working fluid. At a inclination angle $6^{\circ}$, the 200-mesh screen wick 3-layer is shown the best heat transfer performance.

  • PDF

Flexible Modules Using MEMS Technology (MEMS 기술을 이용한 Flexible Module)

  • 김용준;황은수;김용호;이태희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.223-227
    • /
    • 2003
  • A new flexible electronic packaging technology and its medical applications are presented. Conventional silicon chips and electronic modules can be considered as "mechanically rigid box." which does not bend due to external forces. This mechanically rigid characteristic prohibits its applications to wearable systems or bio-implantable devices. Using current MEMS (Microelectromechanical Systems) technology. a surface micromachined flexible polysilicon sensor array and flexible electrode array fer neural interface were fabricated. A chemical thinning technique has been developed to realize flexible silicon chip. To combine these techniques will result in a realization of truly flexible sensing modules. which are suitable for many medical applications.

  • PDF

The Impact of TDDB Failure on Nanoscale CMOS Digital Circuits

  • Kim, Yeon-Bo;Kim, Kyung-Ki
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.3
    • /
    • pp.27-34
    • /
    • 2012
  • This paper presents the impact of time dependent dielectric breakdown (TDDB, also called as gate oxide breakdown) failure on nanoscale digital CMOS Circuits. Recently, TDDB for ultra-thin gate oxides has been considered as one of the critical reliability issues which can lead to performance degradation or logic failures in nanoscale CMOS devices. Also, leakage power in the standby mode can be increased significantly. In this paper, TDDB aging effects on large CMOS digital circuits in the 45nm technology are analyzed. Simulation results show that TDDB effect on MOSFET circuits can result in more significant increase of power consumption compared to delay increase.

Modeling of Capacitive Coplanar Waveguide Discontinuities Characterized with a Resonance Method (공진 주파수 측정방법을 이용한 Coplanar Waveguide 용량성 불연속 구조 설계)

  • Kim, Dong-Young;Jee, Yong
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.181-184
    • /
    • 2001
  • A coplanar waveguide(CPW) on a dielectric substrate consists of a center strip conductor with semi-infinite ground planes on either side. This type of waveguide offers several advantages over microstrip line. It facilitates easy shunt as well as series mounting of active and passive devices. It eliminates the need for wraparound and via holes, and it has a low radiation loss. These, as well as several other advantages, make CPW ideally suited for microwave integrated circuit applications. However, very little information is available in the literature on models for CPW discontinuities. This lack of sufficient discontinuity models for CPW has limited the application of CPW in microwave circuit design. We presented for the characteristics of coplanar waveguide open end capacitance and series gap capacitance. Measurements by utilizing the resonance method were made and the experimental data confirmed the validity of theories. The relationships between the CPW capacitances and the physical dimensions were studied.

  • PDF