• Title/Summary/Keyword: Electron control unit

Search Result 48, Processing Time 0.029 seconds

Numerical Analysis for the Image Evaluation of a Thermionic SEM (열전자형 주사전자현미경 결상특성의 수치해석)

  • Jung, H.U.;Park, M.J.;Kim, D.H.;Jang, D.Y.;Park, K.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.153-158
    • /
    • 2007
  • The present study covers numerical analysis of a thermionic scanning electron microscope(SEM) column. The SEM column contains an electron optical system in which electrons are emitted and moved to form a focused beam, and this generates secondary electrons from the specimen surfaces, eventually making an image. The electron optical system mainly consists of a thermionic electron gun as the beam source, the lens system, the electron control unit, and the vacuum unit. For a systematic design of the electron optical system, the beam trajectories are investigated through numerical analyses by tracing the ray path of the electron beams, and the quality of resulting image is evaluated from the analysis results.

Finite Element Analysis for Electron Optical System of a Thermionic SEM (열전자방사형 주사전자 현미경 전자광학계의 유한요소해석)

  • Park, Keun;Jung, Huen-U.;Kim, Dong-Hwan;Jang, Dong-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1288-1293
    • /
    • 2007
  • The present study covers the design and analysis of a thermionic scanning electron microscope (SEM) column. The SEM column contains an electron optical system in which electrons are emitted and moved to form a focused beam, and this generates secondary electrons from the specimen surfaces, eventually making an image. The electron optical system mainly consists of a thermionic electron gun as the beam source, the lens system, the electron control unit, and the vacuum unit. In the design process, the dimension and capacity of the SEM components need to be optimally determined with the aid of finite element analyses. Considering the geometry of the filament, a three-dimensional (3D) finite element analysis is utilized. Through the analysis, the beam emission characteristics and relevant trajectories are predicted from which a systematic design of the electron optical system is enabled. The validity of the proposed 3D analysis is also discussed by comparing the directional beam spot radius. As a result, a prototype of a thermionic SEM is successfully developed with a relatively short time and low investment costs, which proves the adoptability of the proposed 3D analysis.

  • PDF

The Application and Verification of the 2MVA Battery Energy Storage System(BESS) with Wind-turbine in Micro-grid of Gapado, Jeju (가파도 마이크로그리드에서의 풍력발전 연계를 위한 2MVA급 배터리 에너지 저장시스템(BESS) 적용 및 실증)

  • Kim, Seung-Mo;Oh, Seung-Jin;Lee, Jong-Hak;Kim, Tae-Hyeong;Kwon, Byung-Ki;Ahn, Jae-Min;Jin, Kyung-Min;Choi, Chang-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.303-311
    • /
    • 2014
  • This paper shows the test result of 2MVA BESS(Battery Energy Storage System) with wind-turbine in micro-grid of the Gapado. To implement of micro-grid with BESS, characteristics of generator and customer load in grid are considered. Also, to operate of 2-parallel PCU(Power Conversion Unit) in BESS, the droop control is adopted with operating mode of grid independent. Performances of BESS with wind-turbine were verified by analysis of power quality such as voltage harmonics, ratio of voltage and frequency regulation, and by measurement of waveform such as output voltage and current.

Study of 3 dimensional wide area continuous laser micro patterning (3차원 대면적 연속 마이크로 레이저 패터닝을 위한 연구)

  • Kim, Kyunghan;Sohn, Hyonkee;Lee, Jaehoon
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.1-5
    • /
    • 2015
  • For continuous laser micro patterning on three-dimensional free form surface, innovative laser system is developed. The two axis galvanometer is combined with the dynamic focusing unit to increase optical distance. Also, it is synchronized with the 3 axis mechanical system. To determine laser machining sequence, laser CAM system is developed. It can make possible of 3D surface micro patterning under $25{\mu}m$ pattern width. The uniformity of pattern width is about 2.8% and it is validated that focal plane is well conserved by the dynamic focusing unit. Velocity and positional information of 1 axis is stage is fed to the scanner control board by the encoder signal and it makes possible real time synchronization. With this system, possible patterning volume is enlarged from $40{\times}40mm^2$ to $40{\times}120{\times}30mm^3$.

A Study on the Auto Fuel Feeding Control System using Hall Sensor (홀 센서를 이용한 자동연료공급 제어장치에 관한 연구)

  • Kim, Gyu-Sung;Cho, Myung-Hyun
    • 전자공학회논문지 IE
    • /
    • v.43 no.3
    • /
    • pp.34-40
    • /
    • 2006
  • Usually, fluid or fuel supply device need space to need special sensor to control motor, attaches with ancillary equipment to attach sensor. Also, difficult point follows need signal line and other circuit etc. In this paper, used that proposed control system that use hall sensor to solve discomfort and problem and difference control principle of system happens in current flow according to motor action step. Also, could reduce breakdown by sensor establishment, reduce material costs and personnel expenses as well as control system superior. Auto-pumping system sees that will can apply, develop several kind of device that use system hereafter to all fluid supply systems through soft-ware adaptation.

The Control and Motion Characteristics of 5 axis Vacuum Stage for Electron Beam Lithography (전자빔 가공기용 진공 5축 스테이지의 제어 및 운동특성)

  • 이찬홍;박천홍;이후상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.890-893
    • /
    • 2004
  • The ultra precision machining in industrial field are increased day by day. The diamond turning has been used generally, but now is faced with limitation of use, because of higher requirement of production field. The electron beam lithography is alternative in machining area as semiconductor production. For EB lithography, 5 axis vacuum stage is required to duplicate small and large patterns on wafer. The stage is composed of 2 rotational axis and 3 translational axis with 5 DC servo motors. The positioning repeatability and resolution of Z axis feed unit are 3.21$\mu$m and 0.5 $\mu$m/step enough to apply to lithography.

  • PDF

Fabrication and Properties of OLEDs using PECCP Langmuir-Blodgett(LB) Films (PECCP LB 박막을 이용한 유기 발광 타이모드의 제작과 이의 특성)

  • Lee, Ho-Sik;Lee, Won-Jae;Park, Myung-Gyu;Songe, Min-Jeng;Park, Jong-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.831-834
    • /
    • 2000
  • Characteristics of organic light-emitting diodes(OLEDs) were studied with devices made by PECCP[poly(3,6-N-2-ethylhexyl carbazolyl cyanoterephthalidene)] Langmuir-Blodget(LB) films. The emissive organic material was synthesized and named PECCP, which has a strong electron donor group and an electron accepter group in main chain repeated unit. The LB technique was employed to investigate the identification of the recombination zone in the ITO/PECCP LB films/Alq$_3$/Al structure by varying the LB film thickness. PECCP was considered as an emissive layer and Alq$_3$was used as an electron-transport layer. We measured current-voltage(I-V) characteristics, UV/visible absorption, PL spectrum, and EL spectrum of those devises.

  • PDF

A Study about Experimental Evaluation of an Ultrasonic Surgery Unit for Bone-cutting (골 절삭용 초음파 수술기의 실험적 평가에 관한 연구)

  • Sa, Min-Woo;Shim, Hae-Ri;Ko, Tae-Jo;Lee, Jong-Min;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In the dentistry field, an ultrasonic surgery unit is widely used in bone cutting and scaling to reduce operation time and minimize hemorrhage. The purpose of this study was to evaluate bone cutting and the effect of a specimen's temperature on the two-type ultrasonic surgery unit using a handpiece moving system(HMS). A HMS, which can cut the bone, was developed to perform the experimental procedure with precision of motion control. Bone specimens were prepared from a combination of epoxy-hardener and cortical bone of bovine leg. Through the bone-cutting experiment, the cutting depth was evaluated by not only scanning electron microscopy, but also Vernier calipers. Also, the temperature distribution was measured by a thermo-graphic camera. This study may be applied methodically in various experimental evaluations on a performance test by a HMS.

Microstructure of Fat Free Plain Set-type Yogurt Containing Folic Acid

  • Kayanush J. Aryana
    • Food Science of Animal Resources
    • /
    • v.24 no.3
    • /
    • pp.273-276
    • /
    • 2004
  • The objective of this study was to investigate the microstructure of folic acid-contained yogurt. Folic acids (25 and 50%) were added to milk preparation prior to pasteurization, then starter culture was added. The microstructure of yogurt containing folic acid was determined by the size of cluster of casein micelle using scanning electron microscopy and transmission electron microscopy. The cluster of casein micelle in yogurt containing folic acid were showed larger size than in control (p<0.05). In addition of 50% of folic acid, cluster of casein micelle per unit area was exhibited the highest number among tested yogurts. From these results, folic acid concentration of yogurt may be affected by mouth-feel of yogurt texture as well as the aggregation of casein micelle.

Study on the Structural Design of an Ultra-miniaturized Microcolumn with a Built-in Electrostatic Octupole Stigmator (정전형 8중극 비점수차 보정기가 내장된 극초소형 마이크로컬럼의 구조 설계 연구)

  • Tae Sik Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.3
    • /
    • pp.52-61
    • /
    • 2023
  • We designed a novel ultra-miniaturized microcolumn structure having an stigmator to significantly improve throughput per unit time, which is the biggest disadvantage of microcolumns. We adopted the structure of the stigmator in the form of an electrostatic octupole electrode, and used an electrostatic quadrupole deflector with a relatively simple structure considering the increase in wiring due to the introduction of the stigmator. We have dramatically reduced the effect of astigmatism that occurs when the electron beam probe is scanned to the periphery of the target by introducing the stigmator between the control electrode and the deflector. As our numerical analysis simulation results, the field of view obtained as a result of this study is about 46.3% improved compared to our previous study, and the electron beam probe size of less than 10 nm was achieved in the entire field of view.

  • PDF