• Title/Summary/Keyword: Electromagnetic Imaging

Search Result 196, Processing Time 0.034 seconds

Critical Enhancement of Photothermal Effect by Integrated Nanocomposites of Gold Nanorods and Iron Oxide on Graphene Oxide

  • Yun, Kum-Hee;Seo, Sun-Hwa;Kim, Bo-Mi;Joe, Ara;Han, Hyo-Won;Kim, Jong-Young;Jang, Eue-Soon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2795-2799
    • /
    • 2013
  • Irradiation of gold nanorods (GNRs) with laser light corresponding to the longitudinal surface plasmon oscillation results in rapid conversion of electromagnetic energy into heat, a phenomenon commonly known as the photothermal effect of GNRs. Herein, we propose a facile strategy for increasing the photothermal conversion efficiency of GNRs by integration to form graphene oxide (GO) nanocomposites. Moreover, conjugation of iron oxide (IO) with the GO-GNR nanohybrid allowed magnetic enrichment at a specific target site and the separated GO-IO-GNR assembly was rapidly heated by laser irradiation. The present GO-IO-GNR nanocomposites hold great promise for application in various biomedical fields, including surface enhanced Raman spectroscopy imaging, photoacoustic tomography imaging, magnetic resonance imaging, and photothermal cancer therapy.

Efflorescence assessment using hyperspectral imaging for concrete structures

  • Kim, Byunghyun;Cho, Soojin
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.209-221
    • /
    • 2018
  • Efflorescence is a phenomenon primarily caused by a carbonation process in concrete structures. Efflorescence can cause concrete degradation in the long term; therefore, it must be accurately assessed by proper inspection. Currently, the assessment is performed on the basis of visual inspection or image-based inspection, which may result in the subjective assessment by the inspectors. In this paper, a novel approach is proposed for the objective and quantitative assessment of concrete efflorescence using hyperspectral imaging (HSI). HSI acquires the full electromagnetic spectrum of light reflected from a material, which enables the identification of materials in the image on the basis of spectrum. Spectral angle mapper (SAM) that calculates the similarity of a test spectrum in the hyperspectral image to a reference spectrum is used to assess efflorescence, and the reference spectral profiles of efflorescence are obtained from theUSGS spectral library. Field tests were carried out in a real building and a bridge. For each experiment, efflorescence assessed by the proposed approach was compared with that assessed by image-based approach mimicking conventional visual inspection. Performance measures such as accuracy, precision, and recall were calculated to check the performance of the proposed approach. Performance-related issues are discussed for further enhancement of the proposed approach.

2D Image Construction from Low Resolution Response of a New Non-invasive Measurement for Medical Application

  • Hieda, Ichiro;Nam, Ki-Chang
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.385-393
    • /
    • 2005
  • This paper presents an application of digital signal processing to data acquired by the radio imaging method (RIM) that was adopted to measure moisture distribution inside the human body. RIM was originally developed for the mining industry; we are applying the method to a biomedical measurement because of its simplicity, economy, and safety. When a two-dimensional image was constructed from the measured data, the method provided insufficient resolution because the wavelength of the measurement medium, a weak electromagnetic wave in a VHF band, was longer than human tissues. We built and measured a phantom, a model simulating the human body, consisting of two water tanks representing large internal organs. A digital equalizer was applied to the measured values as a weight function, and images were reconstructed that corresponded to the original shape of the two water tanks. As a result, a two-dimensional image containing two individual peaks corresponding to the original two small water tanks was constructed. The result suggests the method was applicable to biomedical measurement by the assistance of digital signal processing. This technique may be applicable to home-based medical care and other situations in which safety, simplicity, and economy are important.

  • PDF

Subsurface Imaging by a Small-loop EM Survey (소형루프 전자탐사법에 의한 지하 영상화)

  • Lim Jin-Taik;Cho In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.4
    • /
    • pp.187-194
    • /
    • 2003
  • A small-loop electromagnetic (EM) system using multiple frequencies has advantages in survey speed and cost despite of limitation on its depth of investigation. Therefore, small-loop EM surveys have been frequently used on various site investigations involving engineering and environmental problems. We have developed a subsurface imaging technique using small loop EM data. We used a one-dimensional (ID) inversion method to reconstruct a subsurface image from frequency EM sounding data. Tests using simulated data show that the method can reasonably recover the subsurface resistivity structure. Also, the method was tested on field data obtained with multiple frequency small loop EM system at a farm in Chunchon, Korea. The resistivity image obtained form field data compares favorably with the image from the dipole-dipole resistivity survey.

Effect of Pulse Magnetic Field Stimulus on Blood Flow using Digital Infrared Thermal Imaging (체열진단을 통한 펄스자기장 자극기의 혈류개선효과 고찰)

  • Lee, Hyun-Sook
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.5
    • /
    • pp.180-184
    • /
    • 2011
  • The changes in the blood flow in the peripheral vascular system under strong pulsed magnetic fields (pMF) were studied by digital infrared thermal imaging (DITI). After pMF stimulus temperatures in stimulated area were commonly increased in both groups of age and gender. In order to reduce heat generated from coil in pMF stimulus system plastic moldings were fabricated, so that certain distance was kept between stimulus system and the skin and to prevent direct contact to the skin. It is believed that skin temperature is increased by internal electromagnetic energy stimulated the peripheral vascular system by non-contact method.

Investigation on the EMI Noise Reduction of LED Lighting Module in Hospital (병원내 LED 조명기구의 전자파 저감대책)

  • Song, Min-Jong;Cho, Hyun-Seob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.385-388
    • /
    • 2011
  • The electromagnetic wave occurs primarily LED lighting equipment in the interior medical imaging information a lot of high-frequency equipment environment installation. It generated by lighting fixtures mach damage to patients as well as non or no operation. It can be reduced through noise attenuation and filter change. It associated with the capacitors and inductors can reduce by are used frequency efficiently, Attenuation circuit does not significantly affect the radiation medical equipment devices

  • PDF

Measurement of Concrete Thickness at Different Frequency Ranges Using Radar (레이더의 주파수대역 변화에 따른 콘크리트 시편의 두께측정)

  • 김유석;임흥철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.773-778
    • /
    • 1998
  • For imaging of concrete specimens using radar, the principles of radar, microwave, and the electromagnetic properties of concrete are discussed. Experimental data obtained from radar measurement of concrete specimens with no steel bars at three different frequency bandwidths of 2~3.4 GHz, 3.4~5.8 GHz and 8~12 GHz are processed to determine the thickness of the specimens. A signal processing scheme has been implemented to visualize the concrete specimens. The purpose of this study is to determine particular frequency range appropriate for measuring the thickness of concrete specimens using radar.

  • PDF

B1+ Homogenizaion over Whole Field of View in High Field MRI (고자장 MRI에서의 영상 영역에 대한 B1+ 균질성)

  • Kim, Hong-Joon;Son, Hyeok-Woo;Cho, Young-Ki;Yoo, Hyoung-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.96-100
    • /
    • 2012
  • In high static field magnetic resonance imaging(MRI) systems, $B_0$ fields of 7 T and 9.4 T, the impressed RF field shows larger inhomogeneity than in clinical MRI systems with B0 fields of 1.5 T and 3.0 T. In multi-channel RF coils, the magnitude and phase of the input to each coil element can be controlled independently to reduce the non-uniformity of the impressed RF $B_1^+$ field. The convex optimization technique has been used to obtain the optimum excitation parameters with iterative solutions for homogeneity in a selected ROI(Region of Interest). To demonstrate the technique, the multichannel transmission line coil was modeled together with a human head phantom at 400 MHz for the 9.4 T MRI system and $B_1^+$ fields are obtained. In this paper, all the optimized $B_1^+$ in each isolated ROIs are combined to achieve significantly improved homogeneity over the entire field of view. The simulation results for 9.4 T MRI systems are discussed in detail.

Fast numerical methods for marine controlled-source electromagnetic (EM) survey data based on multigrid quasi-linear approximation and iterative EM migration (다중격자 준선형 근사 및 반복적 전자탐사 구조보정법에 기초한 해양 인공송신 전자탐사 자료의 빠른 수치해석 기법)

  • Ueda, Takumi;Zhdanov, Michael S.
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • In this paper we consider an application of the method of electromagnetic (EM) migration to the interpretation of a typical marine controlled-source (MCSEM) survey consisting of a set of sea-bottom receivers and a moving electrical bipole transmitter. Three-dimensional interpretation of MCSEM data is a very challenging problem because of the enormous number of computations required in the case of the multi-transmitter and multi-receiver data acquisition systems used in these surveys. At the same time, we demonstrate that the MCSEM surveys with their dense system of transmitters and receivers are extremely well suited for application of the migration method. In order to speed up the computation of the migration field, we apply a fast form of integral equation (IE) solution based on the multigrid quasi-linear (MGQL) approximation which we have developed. The principles of migration imaging formulated in this paper are tested on a typical model of a sea-bottom petroleum reservoir.

Algorithm Study for Diagnosis the Breast Cancer Using LMA and FDTD (LMA와 FDTD를 이용한 유방암 진단용 알고리즘 연구)

  • Seo, Min-Gyeong;Kim, Tae-Hong;Mun, Ji-Yeon;Jeon, Soon-Ik;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1124-1131
    • /
    • 2011
  • In this paper, image reconstruction algorithm for breast cancer detection using MT(Microwave Tomography) was investigated. The breast cancer detection system under development uses 16 transmit/receive antennas. The signal waveform was a sinusoidal wave at 900 MHz. To solve the 2D inverse scattering problem, we used the 2D FDTD (Finite Difference Time Domain) method for forward calculation and LMA(Levenberg-Marquardt Algorithm) for optimization. The result of the image reconstruction using the numerical phantom by MRI(Magnetic Resonance Imaging) obtained from real patient of breast cancer showed that we can detect the position of the tumor accurately.