• Title/Summary/Keyword: Electroless deposition

Search Result 164, Processing Time 0.023 seconds

Cu Diffusion Behavior of Ni-B Diffusion Barrier Fabricated by Electroless Deposition (무전해 도금법으로 제조된 Ni-B 확산 방지막의 Cu 확산 거동)

  • Choi, Jae-Woong;Hwang, Gil-Ho;Han, Won-Kyu;Lee, Wan-Hee;Kang, Sung-Goon
    • Korean Journal of Materials Research
    • /
    • v.15 no.9
    • /
    • pp.577-584
    • /
    • 2005
  • Thin Ni-B layer, $1{\mu}m$ thick, was electrolessly deposited on Cu electrode fabricated by electro-deposition. The purpose of the layer is to encapsulate Cu electrodes for preventing Cu oxidation and to serve as a diffusion barrier. The layers were annealed at $580^{\circ}C$ with and without pre-annealing at $300^{\circ}C$ for . 30minutes. In the layer with pre-annealing, the amount of Cu diffusion was lower about 5 times than the layer without pre-annealing. The difference in Cu concentration may be attributed to $Ni_3B$ formation prior to Cu diffusion. However, the difference in Cu concentration decreased during the annealing time of 5 h due to the grain growth of Ni.

pH Effects of Electroless Ni Plating on ABS Plastics

  • Song, T.H.;Lee, J.K.;Ryoo, K.K.;Lee, Y.B.
    • Corrosion Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.26-29
    • /
    • 2004
  • Metal plated plastics are becoming more prevalent in materials of communication parts. A new technique MmSH is a process of injecting plastics to produce innovated physical properties compared to the conventional injection process. This study involves two ways of coating plastics Ni by electroless plating and varying bath and plasma treatment for improved adhesion strength between plating layer and surface. MmSH injection processed ASS with plasma treated after neutralization showed a superior adhesion force and a gloss and rate of deposition when it was in pH 7.5. On the other hand, conventional injection processed ASS was in pH 6.5.

Micro patterning of conductor line by laser induced forward transfer(LIFT) (LIFT 방법에 의한 전도성 미세 패터닝 공정 연구)

  • 이제훈;한유희
    • Laser Solutions
    • /
    • v.2 no.3
    • /
    • pp.52-61
    • /
    • 1999
  • The laser induced forward transfer(LIFT) technique employs a pulsed laser to transfer parts of a thin metal film from an optically transparent target onto an arbitrary substrate in close proximity to the metal film on the target. In this work, a two-step method, the combination of LIFT process, in which a Au film deposited on the $Al_2$O$_3$ substrate by Nd:YAG laser and subsequent Au electroless metal plating on the by LIFT process generated Au seed, was presented. The influence of laser parameters, wavelength, laser power, film thickness and overlap ratio of pulse tracks, on the shapes of deposit and conductor line after electroless plating is experimentally studied. As a results, the threshold power densities for ablation, deposition and metallization were determined and comparison of threshold value between the wave length 1064nm and the second harmonic generated 532nm. In odor to determine a possible application in the electronic industry, a smallest conduct spot size, line width and isolated line space were generated.

  • PDF

GOLD WIRE BONDABILITY OF ELECTROLESS GOLD PLATING USING DISULFITEAURATE COMPLEX

  • Abe, Shinji;Watanabe, Hideto;Igarashi, Yasushi;Honma, Hideo
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.714-719
    • /
    • 1996
  • For the fabrication of the circuits, contact or terminal areas are usually coated with nickel and gold. Usually, diluted palladium solution is applied to initiate electroless nickel plating on the copper circuits. However, the trace amounts of palladium remains on the resin and it causes the extraneous deposition. We confirmed that selectivity was greatly improved by the treatment with the strong reducing agents such as SBH or DMAB. Bondability was greatly influenced by the contents of phosphorus in the deposited nickel. Stabilizers in the electroless gold plating were also influenced the bonding strength. The baths containing cupferron or potassium nickel cyanide as a stabilizer showed superior bondability. The gold deposits having strong orientation with Au(220) and Au(311) showed good bond ability.

  • PDF

Characteristics of Nickel-Diamond Composite Powders by Electroless Nickel Plating (무전해 니켈 도금법으로 제조된 니켈-다이아몬드 복합분체의 특성)

  • ;;Hoang Tri Hai
    • Journal of Powder Materials
    • /
    • v.11 no.3
    • /
    • pp.224-232
    • /
    • 2004
  • Ni-diamond composite powders with nickel layer of round-top type on the surface of synthetic diamond (140/170 mesh) were prepared by the electroless plating method (EN) with semi-batch reactor. The effects of nickel concentration, feeding rates of reductant, temperature, reaction time and stirring speeds on the weight percentage and morphology of deposited Ni, mean particle size and specific surface area of the composite powders were investigated by Atomic Adsortion Spectrometer, SEM-EDX, PSA and BET. It was found that nucleated Ni-P islands, acted as catalytic sites for further deposition and grown into these relatively thick layers with nodule-type on the surface of diamond by a lateral growth mechanism. The weight percentage of Ni in the composite powder increased with reaction time, feeding rate of reductant and temperature, but decreased with stirring speed. The weight percentage of Ni in Ni-diamond composite powder was 55% at 150 min., 200 rpm and 7$0^{\circ}C$ .

The Effect of Complexing Agent on the Deposit Charateristics in the Electroless Nickel Plating Solution (무전해 니켈 도금액에서 착화제가 도금피막에 미치는 영향)

  • Jeon Jun-Mi;Koo Suck-Bon;Lee Hong-Kee;Park Hae-Duck;Shim Su-Sap
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.6
    • /
    • pp.326-334
    • /
    • 2004
  • Deposit charateristics of Electroless nickel(EN) were investigated with various complexing agents. As expected, the deposition rate of nickel is increased with pH and that of Phosphorous is decreased with pH. The result of SEM investigation shows that the rough surface crystallization is appeared with pH. It is show that the surface resistance of EN deposit is decreased with pH at 85$^{\circ}C$.

A Study on Reusing of Electroless Ni-Cu-P Waste Solution (無電解 Ni-Cu-P 廢 도금액의 재사용에 관한 연구)

  • 오이식
    • Resources Recycling
    • /
    • v.10 no.2
    • /
    • pp.27-33
    • /
    • 2001
  • Reusing of electroless Ni-Cu-P waste solution was investigated in the plating time, plating rate, solution composion and deposit. Plating time of nickel-catalytic surface took longer than that of zincated-catalytic surface. Initial solution with 50f) waste solution additive at batch type was possible to reusing of waste solution. Plating time of initial solution at continuous type took longer 10 times over than that of batch type. Plating time of 50% waste solution additive at continuous type took longer 3.7 times over than that of batch type. Component change of nickel-copper for electroless deposition was greatly affected by depolited inferiority and larger decreased plating rate.

  • PDF

Micro-Heatsink Fabricated by Electroless Plating (무전해 도금으로 제조한 마이크로 히트싱크)

  • An Hyun Jin;Son Won Il;Hong Joo Hee;Hong Jae-Min
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.11-16
    • /
    • 2004
  • Electronic devices are getting smaller due to integration of electronic chip, and heat generated in electronic devices can cause loss of performance and/or reliability of the devices. In this research, metals such as gold, nickel and copper are plated onto a porous membrane by electroless plating method to make an efficient micro-heatsinks. Electroless plating includes sensitization and activation steps in pre-treatment steps. A polycarbonate(PC) membrane was sensitizied, activated and deposited in each metal solution for plating. Among manufactured microfibrils, heat transfer and radiation properties of Ni-microfibril with high surface area were more effective than those of $Au^-$ and Cu-microfibril.

  • PDF

Relationship Between pH and Temperature of Electroless Nickel Plating Solution

  • Nguyen, Van Phuong;Kim, Dong-Hyun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.33.1-33.1
    • /
    • 2018
  • pH is expressed mathematically as $pH=-{\log}[H^+]$, is a measure of the hydrogen ion concentration, [$H^+$] to specify the acidity or basicity of an aqueous solution. The pH scale usually ranges from 0 to 14. Every aqueous solution can be measured to determine its pH value. The pH values below 7.0 express the acidity, above 7.0 are alkalinity and pH 7.0 is a neutral solution. The solution pH can be determined by indicator or by measurement using pH sensor, which measuring the voltage generated between a glass electrode and a reference electrode according to the Nernst Equation. The pH value of solutions depends on the temperature and the activity of contained ions. In nickel electroless plating process, the controlled pH value in some limited ranges are extremely important to achieve optimal deposition rate, phosphorus content as well as solution stability. Basically, nickel electroless plating solution contains of $Ni^{2+}ions$, reducing agent, buffer and complexing agents. The plating processes are normally carried out at $82-92^{\circ}C$. However, the change of its pH values with temperatures does not follow any rule. Thus, the purpose of study is to understand the relationship between pH and temperature of some based solutions and electroless nickel plating solutions. The change of pH with changing temperatures is explained by view of the thermal dynamic and the practical measurements.

  • PDF

A Study on Reusing of Electroless Ni-Cu-B Waste Solution (무전해 Ni-Cu-B 폐 도금액의 재사용에 관한 연구)

  • Oh Iee-Sik;Bai Young-Han
    • Resources Recycling
    • /
    • v.12 no.1
    • /
    • pp.18-24
    • /
    • 2003
  • Reusing of electroless Ni-Cu-B waste solution was investigated in the plating time, plating rate, solution composition and deposit. Plating time of nickel-catalytic surface took longer than that of zincated-catalytic surface. Initial solution with 40% waste solution additive at batch type was possible to reusing of waste solution. Plating time of initial solution at continuous type took longer 6 times over than that of batch type. Plating time of 40% waste solution additive at continuous type took longer 2 times over than that of batch type. Component change of nickel-copper for electroless deposition was greatly affected by deposited inferiority and larger decreased plating rate.