• Title/Summary/Keyword: Electrode array

Search Result 224, Processing Time 0.028 seconds

Preliminary Study on Field Emitter Array Cathodes for Electrodymanic Tether Propulsion

  • Kitamura, Shoji;Nishida, Shin'ichiro;Iseki, Yasushi;Okawa, Yasushi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.300-305
    • /
    • 2004
  • A preliminary study on. field emitter array cathodes was conducted aiming at applying for electrodymanic tether (EDT) propulsion systems. The EDT propulsion systems are assumed to use for active removal systems of post-mission spacecraft, which would otherwise become space debris. A survey on field emit-ter array cathode technology was conducted, and it showed that carbon nanotube (CNT) emitters are suit-able to EDT application. Trial fabrications and evaluation tests of CNT emitters were conducted, which demonstrated a target emission current density of 10 ㎃/$\textrm{cm}^2$. It was found out that the most important technical issue for developing CNT emitters is to improve the performance against voltage breakdown between the emitter and the opposite electrode.

  • PDF

Development of a Lock-In Amplifier Array for Capacitive Type Pressure Mapping Sensor (정전용량 형 압력맵핑센서를 위한 록인 증폭기 어레이 개발)

  • Kim, Cheong-Worl;Lee, Young-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.4
    • /
    • pp.63-67
    • /
    • 2017
  • In this study, We developed a simple and low cost capacitive pressure mapping sensor and microcontroller-base lock-in amplifier array. We developed capacitive type pressure mapping sensor by forming the electrode and adhesives on plastic films using only the printing process, and the finishing the process by bonding the two films. Lock-in amplifier array was based on a general purpose microcontroller and had only a charge amplifier as analog circuits. In this study, a $10{\times}10$ capacitive type pressure mapping sensor and lock-in amplifier array was fabricated and its characteristics were analyzed.

  • PDF

Fabrication & Properties of Field Emitter Arrays using the Mold Method for FED Application (Mold 법에 의해 제작된 FED용 전계에미터어레이의 특성 분석)

  • ;;;;K. Oura
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.347-350
    • /
    • 2001
  • A typical Mold method is to form a gate electrode, a gate oxide, and emitter tip after fabrication of mold shape using wet-etching of Si substrate. In this study, however, new Mold method using a side wall space structure is used in order to make sharper emitter tip with a gate electrode. Using LPCVD(low pressure chemical vapor deposition), a gate oxide and electrode layer are formed on a Si substrate, and then BPSG(Boro phospher silicate glass) thin film is deposited. After, the BPSG thin film is flowed into a mold as high temperature in order to form a sharp mold structure. Next TiN thin film is deposited as a emitter tip substance. The unfinished device with a glass substrate is bonded by anodic bonding techniques to transfer the emitters to a glass substrate, and Si substrate is etched using KOH-deionized water solution. Finally, we made sharp field emitter array with gate electrode on the glass substrate.

  • PDF

Electrochemical Characterization of Nanosized Electrode Arrays Prepared from Nanoporous Self-Assembled Monolayers

  • Choi, Shin-Jung;Park, Su-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.5
    • /
    • pp.699-704
    • /
    • 2002
  • We characterized nanoelectrode arrays prepared from self-assembled monolayers (SAMs) by adsorption from a solution containing thiolated $\beta$-cyclodextrin ($\beta$-CD) and n-alkanethiol on the gold electrode surface, using electrochemical methods. While the framework, the n-hexadecanethiol SAM, effectively blocked electron transfer between the electrode surface and solution-phase redox probe molecules, the $\beta$-CD cavities isolated in the forests of n-hexadecanethiol molecules were shown to act as an ultramicroelectrode array. The shapes of cyclic voltammograms of probe molecules were related to the number densities of $\beta$-CD molecules within the monolayer films. Probe molecules that have the correct combination of physical and chemical characteristics were shown to effectively penetrate the framework through the $\beta$-CD pores and exchange electrons with the electrode surface.

Development of a Tactile Sensor Array with Flexible Structure Using Piezoelectric Film

  • Yu, Kee-Ho;Kwon, Tae-Gyu;Yun, Myung-Jong;Lee, Seong-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1222-1228
    • /
    • 2002
  • This research is the development of a flexible tactile sensor array for service robots using PVDF (polyvinylidene fluoride) film for the detection of a contact state in real time. The prototype of the tactile sensor which has 8${\times}$8 array using PVDF film was fabricated. In the fabrication procedure, the electrode patterns and the common electrode of the thin conductive tape were attached to both sides of the 281$\mu\textrm{m}$ thickness PVDF film using conductive adhesive. The sensor was covered with polyester film for insulation and attached to the rubber base for a stable structure. The proposed fabrication method is simple and easy to make the sensor. The sensor has the advantages in the implementing for practical applications because its structure is flexible and the shape of the each tactile element can be designed arbitrarily. The signals of a contact force to the tactile sensor were sensed and processed in the DSP system in which the signals are digitized and filtered. Finally, the signals were integrated for taking the force profile. The processed signals of the output of the sensor were visualized in a personal computer, and the shape and force distribution of the contact object were obtained. The reasonable performance for the detection of the contact state was verified through the sensing examples.

Theoretical and experimental studies on influence of electrode variations in electrical resistivity survey for tunnel ahead prediction (터널 굴착면 전방조사를 위한 전기비저항 탐사에서 전극의 변화가 미치는 영향에 대한 이론 및 실험연구)

  • Hong, Chang-Ho;Chong, Song-Hun;Hong, Eun-Soo;Cho, Gye-Chun;Kwon, Tae-Hyuk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.2
    • /
    • pp.267-278
    • /
    • 2019
  • Variety of tunnel ahead prediction methods have been performed for safe tunnel construction during tunnel excavation. Pole-pole array among the electrical resistivity survey, which is one of the tunnel ahead prediction method, has been utilized to predict water-bearing sediments or weak zone located within 5 times of tunnel diameter. One of the most important processes is the estimation of virgin ground resistivity and it can be obtained from the following process: 1) calculation of contact area between the electrodes and the medium, and 2) assumption of the electrodes as equivalent spherical electrodes which have a same surface area with the electrodes. This assumption is valid in a small contact area and sufficient distance between the electrodes. Since the measured resistance, in general, varies with the electrode size, shape, and distance between the electrodes, it is necessary to evaluate the influence of these factors. In this study, theoretical equations were derived and experimental tests were conducted considering the electrode size, shape, and distance of cylindrical electrodes which is the most commonly utilized electrode shape. Through this theoretical and experimental study, it is known that one should be careful to use the assumption of the equivalent half-spherical electrode with large ratio between the penetrated depth and radius of the cylindrical electrode, as the error may get larger.

Application of SP and Pole-pole Array Electrical Resistivity Surveys to the Seawater Leakage Problem of the Embankment (방조제 누수지점 탐지를 위한 SP및 단극배열 전기비저항탐사의 적용)

  • 송성호;이규상;김진호;권병두
    • Economic and Environmental Geology
    • /
    • v.33 no.5
    • /
    • pp.417-424
    • /
    • 2000
  • We applied SP monitoring and resistivity surveys using the pole-pole electrode array to seawater leakage problems in the Youngsan estuary dam and the Eoeun embankment to estimate and detect the zone of seawater leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. For this reason, SP monitoring and the pole-pole array resistivity surveys, which are relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity (EC) and temperature variations along the inner part of Youngsan estuary dam to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincided with tidal variations at each embankment. At the leakage zones in the Youngsan estuary dam and the Eoeun embankment, SP anomalies are in the range of -60~-85 mV and -20~-50 mV, respectively, and true resistivity values obtained by 2-D inversion are 3~15 ohm-m and below 0.3 ohm-m, respectively. Both SP monitoring and the pole-pole array resistivity method are found to be quite effective for investigation of seawater leakage zones in the embankment.

  • PDF

A STUDY ON THE ROLL-ALONG TECHNIQUE USED IN 2D ELECTRICAL RESISTIVITY SURVEYS (2차원 전기비저항 탐사에 사용되는 ROLL-ALONG 기법에 대한 고찰)

  • WonSeokHan;JongRyeolYoon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.155-164
    • /
    • 2003
  • The validity and efficiency of the roll-along technique widely used in 2-D electrical resistivity survey are analyzed in case of the dipole-dipole and the Wenner-Schlumberger arrays by numerical modelling. The shallow anomalous resistivity bodies are successfully inverted both in the dipole-dipole and in the Wenner-Schlumberger arrays because the shallow data of pseudosection are not omitted by the roll-along technique. However, the deep anomalous resistivity bodies can not be well resolved due to the skip of observed data which is more significant in the Wenner-Schlumberger array having relatively poor horizontal coverage of obtaining data. Carrying out electrical survey adopting the dipole-dipole array, the skip of data is insignificant because it is unfeasible to expand the electrodes to the maximum electrode separation coefficient($n_max$) owing to low S/N ratio. In case of the Wenner-Schlumberger array, however, because it is generally feasible to expand the electrodes $n_max$ to the owing to high S/N ratio, it is highly possible that skip of data from the roll-along technique causes significant distortion of inversion results. Therefore, adopting the Wenner-Schlumberger array having deeper median depth(Edwards, 1977) than do the dipole-dipole array on condition of the same unit electrode spacing( ($a$) ) and $n_max$, it is recommended to determine $a$ based on not $n_max$but $n_prob$free from the skip of observing data and forward electrodes with keeping overlap interval 3/4 of the survey line length in order to reduce the distortion of resistivity structure and perform resistivity survey efficiently. These results are confirmed by numerical modelling.

  • PDF

Liquid Crystal Lens Array with Thermally Controllable Focal Length and Electrically Convertible Lens Type

  • Heo, Kyong Chan;Kwon, Jin Hyuk;Gwag, Jin Seog
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.88-94
    • /
    • 2015
  • This paper reports the fabrication of a lenticular liquid crystal (LC) lens array with thermally tunable focus and with the function of a convertible lens type, using the surface structure of a UV-curable polymer and a twisted-nematic (TN) LC cell. The TN LC cell makes the LC lenticular lens function as a converging or diverging lens by controlling electrically the polarization of input light. Therefore, the focal lengths for both the converging and diverging lenses, which can be switched from the TN cell, can be tuned by changing the effective refractive index of the LC by Joule heating of the transparent electrode. As a result, the focal length of the lens with the E7 LC was changed continuously from 8.7 to 31.2 mm for the converging lens type and from -9.8 to -14.2 mm for the diverging lens when the temperature was increased from 25 to $56^{\circ}C$.

Hybridization by an Electrical Force and Electrochemical Genome Detection Using an Indicator-free DNA on a Microelectrode-array DNA Chip

  • Choi, Yong-Sung;Lee, Kyung-Sup;Park, Dae-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.3
    • /
    • pp.379-383
    • /
    • 2005
  • This research aims to develop DNA chip array without an indicator. We fabricated microelectrode array by photolithography technology. Several DNA probes were immobilized on an electrode. Then, indicator-free target DNA was hybridized by an electrical force and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between DNA probe and mismatched DNA in an anodic peak. Immobilization of probe DNA and hybridization of target DNA could be confirmed by fluorescent. This indicator-free DNA chip microarray resulted in the sequence-specific detection of the target DNA quantitatively ranging from $10^{-18}\;M\;to\;10^{-5}$ M in the buffer solution. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.