• 제목/요약/키워드: Electrochemical Detection

검색결과 340건 처리시간 0.028초

Simultaneous Determination of Cd2+, Pb2+, Cu2+ and Hg2+ at a Carbon Paste Electrode Modified with Ionic Liquid-functionalized Ordered Mesoporous Silica

  • Zhang, Penghui;Dong, Sheying;Gu, Guangzhe;Huang, Tinglin
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권10호
    • /
    • pp.2949-2954
    • /
    • 2010
  • Ionic liquid-functionalized ordered mesoporous silica SBA-15 modified carbon paste electrode (CISPE) was fabricated and its electrochemical performance was investigated by cyclic voltammetry, electrochemical impedance spectra. The electrochemical behavior of $Cd^{2+}$, $Pb^{2+}$, $Cu^{2+}$ and $Hg^{2+}$ at CISPE was studied by differential pulse anodic stripping voltammetry (DPASV). Compared with carbon paste electrode, the stripping peak currents had a significant increase at CISPE. Under the optimized conditions, the detection limits were $8.0{\times}10^{-8}\;M$ ($Cd^{2+}$), $4.0{\times}10^{-8}\;M$ ($Pb^{2+}$), $6.0{\times}10^{-8}\;M$ ($Cu^{2+}$), $1.0{\times}10^{-8}\;M$ ($Hg^{2+}$), respectively. Furthermore, the present method was applied to the determination of $Cd^{2+}$, $Pb^{2+}$, $Cu^{2+}$ and $Hg^{2+}$ in water samples and people hair sample.

Electrochemical Investigation of Acetaminophen with a Carbon Nano-tube Composite Film Electrode

  • Li, Chunya;Zhan, Guoqing;Yang, Qingdan;Lu, Jianjie
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1854-1860
    • /
    • 2006
  • Electrochemical behaviors of acetaminophen at a muti-wall carbon nano-tube composite film modified glassy carbon electrode were investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Compared with that obtained at the unmodified electrode, the peak currents were enhanced significantly, and the oxidation peak shifted towards more negative potential with the reduction peak shifted positively. The peak-to-peak separation turned narrow, and suggested that the reversibility was improved greatly. Experimental parameters, such as scan rate, pH and accumulation conditions were optimized. It was found that a maximum current response can be obtained at pH = 5.0 after accumulation at -0.50 V for 80 s. The oxidation peak current was found to be linearly related to acetaminophen concentration over the range of $5.0{\times}10^{-7}\;\sim\;1.0{\times}10^{-4}$ mol $L^{-1}$ with a detection limit of $5.0{\times}10^{-8} $mol $L^{-1}$. A convenient and sensitive electrochemical method was developed for the determination of acetaminophen in a commercial paracetamol oral solution. Its practical application demonstrated that it has good selectivity and high sensitivity.

Highly Sensitive and Selective Glucose Sensor Realized by Conducting Polymer Modified Nanoporous PtZn Alloy Electrode

  • Jo, Hyejin;Piao, Hushan;Son, Yongkeun
    • Journal of Electrochemical Science and Technology
    • /
    • 제4권1호
    • /
    • pp.41-45
    • /
    • 2013
  • Platinum is a well known element which shows a significant electrocatalytic activity in many important applications. In glucose sensor, because of the poisoning effect of reaction intermediates and the low surface area, the electrocatalytic activity towards the glucose oxidation is low which cause the low sensitivity. So, we fabricate a nanoporous PtZn alloy electrode by deposition-dissolution method. It provides a high active surface and a large enzyme encapsulating space per unit area when it used for an enzymatic glucose sensor. Glucose oxidase was immobilized on the electrode surface by capping with PEDOT composite and PPDA. The composite and PPDA also can exclude the interference ion such as ascorbic acid and uric acid to improve the selectivity. The surface area was determined by cyclic voltametry method and the surface structure and the element were analyzed by Scanning Electron Microscope (SEM) and Energy Dispersive X-ray spectroscopy (EDX), respectively. The sensitivity is $13.5{\mu}A/mM\;cm^2$. It is a remarkable value with such simply prepared senor has high selectivity.

오스뮴-쿠페론의 전기화학적 행동 및 응용 (Electrochemical behavior and Application of Osmium-Cupferron Complex)

  • 권영순;정미영
    • 분석과학
    • /
    • 제16권3호
    • /
    • pp.198-205
    • /
    • 2003
  • 쿠페론은 nitrosophenylhydroxylamine의 ammonium salt로서 흡착촉매 벗김법 (AdCtSV)에서 리간드의 역할을 하고 동시에 촉매 역할을 한다고 알려져 있다. 순환 전압전류법을 이용하여, 1 mM 인산염 완충용액에서 오스뮴-쿠페론 착물의 전기화학적 행동을 살펴보았다. 오스뮴 정량의 최적 조건은 1 mM 인산염 완충용액 (pH 6.0), 0.1 mM 쿠페론의 용액에서 주사속도는 100 mV/s 이었다. 이 조건에서 농도 변화에 따른 선형 주사 전압곡선의 환원 봉우리 전류변화를 이용하여 얻은 오스뮴의 검출 한계 ($3{\sigma}$)는 $1.0{\times}10^{-7}M$이다.

생체 세포내 미량 구리의 전기화학적 검출에 관한 연구 (Electrochemical Detection of Trace Level Copper in in vivo Cell)

  • 이장현
    • 한국환경과학회지
    • /
    • 제21권11호
    • /
    • pp.1333-1338
    • /
    • 2012
  • In order to measure the minute amount of Cu(II) in our environment, cyclic voltammetry (CV) and square-wave stripping voltammetry (SWSV) were performed for a trace copper assay using bismuth immobilized on a carbon nanotube paste electrode. An analytical working range of 30 to $240{\mu}g/L$ Cu(II) was obtained for CV and SWSV. The SWSV precision obtained was 0.47 % (n = 15) RSD in $30.0{\mu}g/L$ Cu(II). The detection limit obtained was 3.1 ng/L Cu(II) using SWSV, while the CV yielded the nano-range detection limit through the pre-concentration step. By using this research method, Cu(II) value could be determined in the urine of human sample and in the brain of fish sample. This research can be effectively applied to other cases of measuring minute amount of Cu(II) in living organisms.

Hybridization by an Electrical Force and Electrochemical Genome Detection Using an Indicator-free DNA on a Microelectrode-array DNA Chip

  • Choi, Yong-Sung;Lee, Kyung-Sup;Park, Dae-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.379-383
    • /
    • 2005
  • This research aims to develop DNA chip array without an indicator. We fabricated microelectrode array by photolithography technology. Several DNA probes were immobilized on an electrode. Then, indicator-free target DNA was hybridized by an electrical force and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between DNA probe and mismatched DNA in an anodic peak. Immobilization of probe DNA and hybridization of target DNA could be confirmed by fluorescent. This indicator-free DNA chip microarray resulted in the sequence-specific detection of the target DNA quantitatively ranging from $10^{-18}\;M\;to\;10^{-5}$ M in the buffer solution. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.

파라세타몰 검출을 위한 전기화학적 다중효소 바이오센서 (Tri-enzyme modified electrochemical biosensor for paracetamol detection)

  • 박덕수;심윤보;장승철
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.29-34
    • /
    • 2008
  • A new disposable amperometric tri-enzyme biosensor for the detection of paracetamol has been developed. The paracetamol sensors developed uses horseradish peroxidase modified screen-printed carbon electrodes (HRP-SPCEs) coupled with immobilized enzymes, tyrosinase and aryl acylamidase, prepared using a poly (vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ) matrix. Optimization of the experimental parameters has been performed and the paracetamol biosensor showed detection limit for paracetamol is as low as $100{\mu}M$ and the sensitivity of the sensor is $1.46nA{\mu}M^{-1}cm^{-2}$.

Noble Metal Nanowire Based SERS Sensor

  • 강태준
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.87-87
    • /
    • 2013
  • The interface between nanomaterials and biosystems is emerging as one of the broadest and most dynamic areas of science and technology, bringing together biology, chemistry, physics and many areas of engineering, biomedicine. The combination of these diverse areas of research promised to yield revolutionary advances in healthcare, medicine, and life science. For example, the creation of new and powerful nanosensors that enable direct, sensitive, and rapid analysis of biological and chemical species can advance the diagnosis and treatment of disease, discovery and screening of new drug molecules. Nanowire based sensors are emerging as a powerful and general platform for ultrasensitive and multiplex detection of biological and chemical species. Here, we present the studies about noble metal nanowire sensors that can be used for sensitive detection of a wide-range of biological and chemical species including nucleic acids, proteins, and toxic metal ions. Moreover, the optical and electrochemical applications of noble metal nanowires are introduced. Noble metal nanowires are successfully used as plasmonic antennas and nanoelectrodes, thereby provide a pathway for a single molecule sensor, in vivo neural recording, and molecular injection and detection in a single living cell.

  • PDF

Hemoglobin-DNA/pyterpy 박막을 이용한 과산화수소의 전기화학적 검출 (Electrochemical Detection of Hydrogen Peroxide based on Hemoglobin-DNA/pyterpy Modified Gold Electrode)

  • 이동윤;최원석;박상현;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1295-1296
    • /
    • 2008
  • Hydrogen peroxide ($H_2O_2$) biosensor is one of the most developing sensors because this kind of sensors is highly selective and responds quickly to the specific substrate. Hemoglobin (Hb) has been used as ideal biomolecules to construct hydrogen peroxide biosensors because of their high selectivity to $H_2O_2$. The direct electron transfer of Hb has widely investigated for application in the determination of $H_2O_2$ because of its simplicity, high selectivity and intrinsic sensitivity. An electrochemical detection for hydrogen peroxide was investigated based on immobilization of hemoglobin on DNA/Fe(pyterpy)$^{2+}$ modified gold electrode. The pyterpy monolayers were firstly an electron deposition onto the gold electrode surface of the quartz crystal microbalance (QCM). It is offered a template to attach negatively charged DNA. The fabrication process of the electrode was verified by quartz crystal analyzer (QCA). The experimental parameters such as pH, applied potential and amperometric response were evaluated and optimized. Under the optimized conditions, this sensor shows the linear response within the range between $3.0{\times}10^{-6}$ to $9.0{|times}10^{-4}$ M concentrations of $H_2O_2$. The detection limit was determined to be $9{\times}10^{-7}$ M (based on the S/N=3).

  • PDF

금 처리를 통한 PEDOT 마이크로튜브 전극의 과산화수소 검출 특성 향상 (Enhanced Sensitivity of PEDOT Microtubule Electrode to Hydrogen Peroxide by Treatment with Gold)

  • 박종서;손용근
    • 폴리머
    • /
    • 제38권6호
    • /
    • pp.809-814
    • /
    • 2014
  • 전류 감응형 바이오센서에 응용하기 위해 전도성 고분자 마이크로튜브 어레이를 제작하였다. Poly(3,4-ethylenedioxythiophene)/poly(4-styrenesulfonic acid)(PEDOT/PSS) composite을 전도성 접착제로 하여 템플릿을 전극에 고정한 후 EDOT을 전기화학적으로 중합하였다. 마이크로튜브 어레이는 자체의 넓은 표면적으로 인해 감도 높은 바이오센서로 응용될 수 있으나, 주요 표적물질 중의 하나인 과산화수소에 대한 전기화학적 반응이 느렸다. 과산화수소 산화에 대한 감도를 향상시키기 위해 어레이 전극에 금을 도포하였다. 증착법과 전기화학적 석출법 두 가지 방법을 시도하여 금을 처리하였는데, 이렇게 처리한 전극은 모두 과산화수소에 대한 반응이 크게 향상되었다. 따라서 전도성 고분자 마이크로튜브 어레이에 금을 도포함으로써 과산화수소를 표적물질로 하는 감도 높은 바이오센서 제작이 가능할 것으로 기대된다.