References
- P. Routledge, J. A. Vale, D. N. Bateman, G. D. Johnston, A. Judd, S. Thomas, G. Volans, L. F. Prescott, and A. Proudfoot, 'Paracetamol (acetaminophen) poisoning-No need to change current guidelines to accident departments', British Medical Journal, vol. 317, pp. 1609-1610, 1998 https://doi.org/10.1136/bmj.317.7173.1609
- A. Vale, 'Paracetamol (acetaminophen)', Medicine, vol. 35, pp. 643-645, 2007 https://doi.org/10.1016/j.mpmed.2007.09.011
- P. J. Zed and E. P. Krenzelok, 'Treatment of acetaminophen overdose', American J. of Health System Pharmacy, vol. 56, pp. 1081-1091, 1999
- L. de Haro, L. Tichadou, N. Prost, C. Perringue, G. Drouet, F. Rodor, M. Valli, and J. Arditti, 'Accidental ingestion of paracetamol in the form of paediatric syrup (EFFERALGAN). Experience of marseille poison control centre in 1998', Therapie, vol. 54, pp. 771-773, 1999
- E. Dinc, C. Yucesoy, and F. Onur, 'Simultaneous spectrophotometric determination of mefenamic acid and paracetamol in a pharmaceutical preparation using ratio spectra derivative spectrophotometry and chemometric methods', J. Pharmaceutical and Biomedical Analysis, vol. 28, pp. 1091-1100, 2002 https://doi.org/10.1016/S0731-7085(02)00031-6
- K. K. Verma, A. Jain, and K. K. Stewart, 'Flowinjection spectroptometric determination of acetaminophen in drug formulations', Analytica Chimica Acta, vol. 261, pp. 261-267, 1992 https://doi.org/10.1016/0003-2670(92)80200-Q
- A. Criado, S. Cardenas, M. Gallego, and M. Valcarcel, 'Continuous flow spectrophotometric determination of paracetamol in pharmaceuticals following continuous microwave assisted alkaline hydrolysis', Talanta, vol. 53, pp. 417-423, 2000 https://doi.org/10.1016/S0039-9140(00)00509-9
- M. K. Srivastava, S. Ahmad, D. Singh, and I. C. Shukla, 'Titrimetric determination of dipyrone and paracetamol with potassium hexacyanoferrate(III) in an acidic medium', Analyst, vol. 110, pp. 735-737, 1985 https://doi.org/10.1039/an9851000735
- J. L. Vilchez, R. Blanc, R. Avidad, and A. Navalon, 'Spectrofluorimetric determination of paracetamol in pharmaceuticals and biological fluids', J. Pharmaceutical and Biomedical Analysis, vol. 13, pp. 1119-1125, 1995 https://doi.org/10.1016/0731-7085(95)01537-U
- O. W. Lau, S. F. Luk, and Y. M. Cheung, 'Simultaneous determination of ascorbic acid, caffeine and paracetamol in drug formulations by differential- pulse voltammetry using a glassy carbon electrode', Analyst, vol. 114, pp. 1047-1051, 1989 https://doi.org/10.1039/an9891401047
- S. Ravisankar, M. Vasudevan, M. Gandhimathi, and B. Suresh, 'Reversed-phase HPLC method for the estimation of acetaminophen, ibuprofen and chlorzoxazone in formulations', Talanta, vol. 46, pp. 1577-1581, 1998 https://doi.org/10.1016/S0039-9140(98)00043-5
- J. Roy, P. Saha, S. Sultana, and A.S. Kenyon, 'Rapid screening of marketed paracetamol tablets: Use of thin-layer chromatography and a semiquantitative spot test', Bulletin of the World Health Organization, vol. 75, pp. 19-22, 1997
- M. L. Ramos, J. F. Tyson, and D. J. Curran, 'Determination of acetaminophen by flow injection with on-line chemical derivatization: Investigations using visible and FTIR spectrophotometry', Analytica Chimica Acta, vol. 364, pp. 107-116, 1998 https://doi.org/10.1016/S0003-2670(98)00146-9
- G., F. Cespedes, S. Alegret, and M. del Valle, 'Sequential injection system with higher dimensional electrochemical sensor signals Part 1. Voltammetric e-tongue for the determination of oxidizable compounds', Talanta, vol. 66, pp. 1187-1196, 2005 https://doi.org/10.1016/j.talanta.2005.01.022
- G. A. Messina, I. E. De Vito, and J. Raba, 'On-line microfluidic sensor integrated with an enzymemodified pre-cell for the monitoring of paracetamol in pharmaceutical samples', Analytica Chimica Acta, vol. 559, pp. 152-158, 2006 https://doi.org/10.1016/j.aca.2005.11.072
- S. F. Wang, F. Xie, and R. F. Hu, 'Carbon-coated nickel magnetic nanoparticles modified electrodes as a sensor for determination of acetaminophen', Sensors and Actuators B-Chemical, vol. 123, pp. 495-500, 2007 https://doi.org/10.1016/j.snb.2006.09.031
- F. W. Scheller, U. Wollenberger, A. Warsinke, and F. Lisdat, 'Research and development in biosensors', Current Opinion in Biotechnology, vol. 12, pp. 35-40, 2001 https://doi.org/10.1016/S0958-1669(00)00169-5
- Y. T. Lee and S. R. Lee, 'Development of the disposable glucose sensor using Cu/Ni/Au electrode', J. Korean Sensors Society, vol. 15, no. 5, pp. 352-356, 2006 https://doi.org/10.5369/JSST.2006.15.5.352
- S. C. Chang and D. S. Park, 'Disposable in-field electrochemical potable sensor system for free available chlorine (FAC) Detection', J. Korean Sensors Society, vol. 16, no. 6, pp. 449-456, 2007 https://doi.org/10.5369/JSST.2007.16.6.449
- S. C. Chang, K. Rawson, and C. J. McNeil, 'Disposable tyrosinase-peroxidase bi-enzyme sensor for amperometric detection of phenols', Biosensors & Bioelectronics, vol. 17, pp. 1015-1023, 2002 https://doi.org/10.1016/S0956-5663(02)00094-5
Cited by
- Alizarin Red S modified electrochemical sensors for the detection of aluminum ion vol.19, pp.6, 2010, https://doi.org/10.5369/JSST.2010.19.6.421
- Disposable Electrochemical Immunosensors for the Detection of Herbicide vol.20, pp.1, 2011, https://doi.org/10.5369/JSST.2011.20.1.35