DOI QR코드

DOI QR Code

Tri-enzyme modified electrochemical biosensor for paracetamol detection

파라세타몰 검출을 위한 전기화학적 다중효소 바이오센서

  • Park, Deog-Su (Center for Innovative Bio. Physio Sensor Technology, Pusan National University) ;
  • Shim, Yoon-Bo (Department of Chemistry, Pusan National University) ;
  • Chang, Seung-Cheol (Center for Innovative Bio. Physio Sensor Technology, Pusan National University)
  • 박덕수 (부산대학교 신개념바이오.피지오센서기술연구센터) ;
  • 심윤보 (부산대학교 화학과) ;
  • 장승철 (부산대학교 신개념바이오.피지오센서기술연구센터)
  • Published : 2008.01.31

Abstract

A new disposable amperometric tri-enzyme biosensor for the detection of paracetamol has been developed. The paracetamol sensors developed uses horseradish peroxidase modified screen-printed carbon electrodes (HRP-SPCEs) coupled with immobilized enzymes, tyrosinase and aryl acylamidase, prepared using a poly (vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ) matrix. Optimization of the experimental parameters has been performed and the paracetamol biosensor showed detection limit for paracetamol is as low as $100{\mu}M$ and the sensitivity of the sensor is $1.46nA{\mu}M^{-1}cm^{-2}$.

Keywords

References

  1. P. Routledge, J. A. Vale, D. N. Bateman, G. D. Johnston, A. Judd, S. Thomas, G. Volans, L. F. Prescott, and A. Proudfoot, 'Paracetamol (acetaminophen) poisoning-No need to change current guidelines to accident departments', British Medical Journal, vol. 317, pp. 1609-1610, 1998 https://doi.org/10.1136/bmj.317.7173.1609
  2. A. Vale, 'Paracetamol (acetaminophen)', Medicine, vol. 35, pp. 643-645, 2007 https://doi.org/10.1016/j.mpmed.2007.09.011
  3. P. J. Zed and E. P. Krenzelok, 'Treatment of acetaminophen overdose', American J. of Health System Pharmacy, vol. 56, pp. 1081-1091, 1999
  4. L. de Haro, L. Tichadou, N. Prost, C. Perringue, G. Drouet, F. Rodor, M. Valli, and J. Arditti, 'Accidental ingestion of paracetamol in the form of paediatric syrup (EFFERALGAN). Experience of marseille poison control centre in 1998', Therapie, vol. 54, pp. 771-773, 1999
  5. E. Dinc, C. Yucesoy, and F. Onur, 'Simultaneous spectrophotometric determination of mefenamic acid and paracetamol in a pharmaceutical preparation using ratio spectra derivative spectrophotometry and chemometric methods', J. Pharmaceutical and Biomedical Analysis, vol. 28, pp. 1091-1100, 2002 https://doi.org/10.1016/S0731-7085(02)00031-6
  6. K. K. Verma, A. Jain, and K. K. Stewart, 'Flowinjection spectroptometric determination of acetaminophen in drug formulations', Analytica Chimica Acta, vol. 261, pp. 261-267, 1992 https://doi.org/10.1016/0003-2670(92)80200-Q
  7. A. Criado, S. Cardenas, M. Gallego, and M. Valcarcel, 'Continuous flow spectrophotometric determination of paracetamol in pharmaceuticals following continuous microwave assisted alkaline hydrolysis', Talanta, vol. 53, pp. 417-423, 2000 https://doi.org/10.1016/S0039-9140(00)00509-9
  8. M. K. Srivastava, S. Ahmad, D. Singh, and I. C. Shukla, 'Titrimetric determination of dipyrone and paracetamol with potassium hexacyanoferrate(III) in an acidic medium', Analyst, vol. 110, pp. 735-737, 1985 https://doi.org/10.1039/an9851000735
  9. J. L. Vilchez, R. Blanc, R. Avidad, and A. Navalon, 'Spectrofluorimetric determination of paracetamol in pharmaceuticals and biological fluids', J. Pharmaceutical and Biomedical Analysis, vol. 13, pp. 1119-1125, 1995 https://doi.org/10.1016/0731-7085(95)01537-U
  10. O. W. Lau, S. F. Luk, and Y. M. Cheung, 'Simultaneous determination of ascorbic acid, caffeine and paracetamol in drug formulations by differential- pulse voltammetry using a glassy carbon electrode', Analyst, vol. 114, pp. 1047-1051, 1989 https://doi.org/10.1039/an9891401047
  11. S. Ravisankar, M. Vasudevan, M. Gandhimathi, and B. Suresh, 'Reversed-phase HPLC method for the estimation of acetaminophen, ibuprofen and chlorzoxazone in formulations', Talanta, vol. 46, pp. 1577-1581, 1998 https://doi.org/10.1016/S0039-9140(98)00043-5
  12. J. Roy, P. Saha, S. Sultana, and A.S. Kenyon, 'Rapid screening of marketed paracetamol tablets: Use of thin-layer chromatography and a semiquantitative spot test', Bulletin of the World Health Organization, vol. 75, pp. 19-22, 1997
  13. M. L. Ramos, J. F. Tyson, and D. J. Curran, 'Determination of acetaminophen by flow injection with on-line chemical derivatization: Investigations using visible and FTIR spectrophotometry', Analytica Chimica Acta, vol. 364, pp. 107-116, 1998 https://doi.org/10.1016/S0003-2670(98)00146-9
  14. G., F. Cespedes, S. Alegret, and M. del Valle, 'Sequential injection system with higher dimensional electrochemical sensor signals Part 1. Voltammetric e-tongue for the determination of oxidizable compounds', Talanta, vol. 66, pp. 1187-1196, 2005 https://doi.org/10.1016/j.talanta.2005.01.022
  15. G. A. Messina, I. E. De Vito, and J. Raba, 'On-line microfluidic sensor integrated with an enzymemodified pre-cell for the monitoring of paracetamol in pharmaceutical samples', Analytica Chimica Acta, vol. 559, pp. 152-158, 2006 https://doi.org/10.1016/j.aca.2005.11.072
  16. S. F. Wang, F. Xie, and R. F. Hu, 'Carbon-coated nickel magnetic nanoparticles modified electrodes as a sensor for determination of acetaminophen', Sensors and Actuators B-Chemical, vol. 123, pp. 495-500, 2007 https://doi.org/10.1016/j.snb.2006.09.031
  17. F. W. Scheller, U. Wollenberger, A. Warsinke, and F. Lisdat, 'Research and development in biosensors', Current Opinion in Biotechnology, vol. 12, pp. 35-40, 2001 https://doi.org/10.1016/S0958-1669(00)00169-5
  18. Y. T. Lee and S. R. Lee, 'Development of the disposable glucose sensor using Cu/Ni/Au electrode', J. Korean Sensors Society, vol. 15, no. 5, pp. 352-356, 2006 https://doi.org/10.5369/JSST.2006.15.5.352
  19. S. C. Chang and D. S. Park, 'Disposable in-field electrochemical potable sensor system for free available chlorine (FAC) Detection', J. Korean Sensors Society, vol. 16, no. 6, pp. 449-456, 2007 https://doi.org/10.5369/JSST.2007.16.6.449
  20. S. C. Chang, K. Rawson, and C. J. McNeil, 'Disposable tyrosinase-peroxidase bi-enzyme sensor for amperometric detection of phenols', Biosensors & Bioelectronics, vol. 17, pp. 1015-1023, 2002 https://doi.org/10.1016/S0956-5663(02)00094-5

Cited by

  1. Alizarin Red S modified electrochemical sensors for the detection of aluminum ion vol.19, pp.6, 2010, https://doi.org/10.5369/JSST.2010.19.6.421
  2. Disposable Electrochemical Immunosensors for the Detection of Herbicide vol.20, pp.1, 2011, https://doi.org/10.5369/JSST.2011.20.1.35