• Title/Summary/Keyword: Electro-hydraulic

Search Result 325, Processing Time 0.027 seconds

Smokeless Starting for 4 Cycle Medium Speed Diesel Engine (4행정 중속 디젤기관의 스모크리스 시동)

  • Jung, Suk-Ho
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.11-16
    • /
    • 2014
  • Although smoke emitted from ships is not included in IMO(International Maritime Organiztion) regulation yet, it is one of the substance what is polluting mainly the air. Especially, its concentration is very high when an engine is started and a load is rapidly changed. This is caused by unburned fuel what is injected more than necessary quantity after combustion period. It is possible to decrease smoke concentration emitted at starting engine by controlling fuel injection quantity, but it is concerned that time to rated speed must be spent. Then a governor what can reduce the smoke concentration without a loss of time to rated speed is needed. We adopted a electro-hydraulic governor what can control dual fuel start limit function and achieved very low level of smoke concentration without greater the loss of time to rated speed.

LQG/LTR Control of Hydraulic Positioning System with Dead-zone (사역대가 포함된 유압 위치 시스템의 LQG/LTR 제어)

  • Kim, In-Soo;Kim, Yeung-Shik;Kim, Ki-Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.8
    • /
    • pp.729-735
    • /
    • 2012
  • A LQG/LTR(linear quadratic Gaussian/loop transfer recovery) controller with an integrator is designed to control the electro-hydraulic positioning system. Without considering the nonlinearity in the dead-zone, computer simulations are performed and show good performances and tracking abilities with the feedback controller based on the linear system model. However, the performance of the closed loop hydraulic positioning system shows big steady-state error in real system because of the dead-zone. In this paper, the feedback controller with a nonlinear compensator is introduced to overcome the dead-zone phenomenon in hydraulic systems. The inverse dead-zone as a nonlinear compensator is used to cancel out the dead-zone phenomenon. Experimental tests are performed to verify the performance of the controller.

Characteristics of Electro-hydraulic Suspension According to Hydraulic Design Variables (유압설계 변수에 따른 전기유압식 현가장치의 특성)

  • Ko, Young-Ho;Lee, Gun-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.171-176
    • /
    • 2008
  • Active suspension controls stiffness and damping between unsprung mass and sprung mass in order to increase the ride quality. However, to increase the riding quality, the handling quality should be decreased and the rattle space should be increased. So, active suspension should cope with these conflict conditions. Therefore its actuating devices have to produce sufficient actuating force and have sufficiently short response time. In this paper, the dynamic characteristics of 1/4 car model with an active suspension is studied according to hydraulic design variables. The active suspension consists of a hydraulic servo valve and a hydraulic cylinder. It shows better performance when it has more powerful and faster actuator.

  • PDF

3D CAD Modeling of a Hydraulic Motor-Load System and Adaptive Control (유압모터-부하계의 3D CAD 모델링 및 적응제어)

  • Cho, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.23-28
    • /
    • 2011
  • This paper investigates the motion control of a hydraulic motor-load system using the Simple Adaptive Control (SAC) method. The plant transfer function has been modelled mathematically. The open-loop responses have been obtained experimentally in order to identify the design parameters of transfer function. The hydraulic motor-load system has been modelled using the 3D CAD and imbedded in the hydraulic circuit simulation program to verify the overall performance. The experimental results confirm that the SAC method gives a good tracking performance compared to the PID control.

Identification and Control of Electro-Hydraulic Servo System Using DDV

  • Kim, Seung-Hyun;Lee, Chang-Don;Lee, Jin-Kul;Lee, Sang-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.169.1-169
    • /
    • 2001
  • In general, for high performance pressure control system, hydraulic system with electo hydraulic servo valve controls flow rate, it contains many nonlinear term like square-root and change of bulk modulus by flow rate. But, DDV(Direct Drive Valve) contains pressure control loop itself, then it can eliminate nonlinearity and achieve linearity for hydraulic system. In this paper, parameter identification method which uses input and ouput data is applied to obtain DDV's mathematical model and parameter assuming that dynamic characteristic of DDV is first order system. Then, the state feedback controller was designed to implement the force control of hydraulic system , and the control performance was evaluated.

  • PDF

LQG/LTR Control of Hydraulic Positioning System with Dead-zone (사역대가 포함된 유압 위치 시스템의 LQG/LTR 제어)

  • Kim, Ki-Bum;Kim, Yeung-Shik;Kim, In-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.614-619
    • /
    • 2012
  • A LQG/LTR(Linear Quadratic Gaussian/Loop Transfer Recovery) controller with an integrator is designed to control the electro-hydraulic positioning system. Without considering the nonlinearity in the dead-zone, computer simulations are performed and show good performances and tracking abilities with the feedback controller based on the linear system model. However, the performance of the closed loop hydraulic positioning system shows big steady-state error in real system because of the dead-zone. In this paper, the feedback controller with a nonlinear compensator is introduced to overcome the dead-zone phenomenon in hydraulic systems. The inverse dead-zone as a nonlinear compensator is used to cancel out the dead-zone phenomenon. Experimental tests are performed to verify the performance of the controller.

  • PDF

Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve (고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF

Automatic Assembly Task of Electric Line Using 6-Link Electro-Hydraulic Manipulators

  • Kyoungkwan Ahn;Lee, Byung-Ryong;Yang, Soon-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1633-1642
    • /
    • 2002
  • Uninterrupted power supply has become indispensable during the maintenance task of active electric power lines as a result of today's highly information-oriented society and increasing demand of electric utilities. The maintenance task has the risk of electric shock and the danger of falling from high place. Therefore it is necessary to realize an autonomous robot system using electro-hydraulic manipulator because hydraulic manipulators have the advantage of electric insulation. Meanwhile it is relatively difficult to realize autonomous assembly tasks particularly in the case of manipulating flexible objects such as electric lines. In this report, a discrete event control system is introduced for automatic assembly task of electric lines into sleeves as one of the typical task of active electric power lines. In the implementation of a discrete event control system, LVQNN (linear vector quantization neural network) is applied to the insertion task of electric lines to sleeves. In order to apply these proposed control system to the unknown environment, virtual learning data for LVQNN is generated by fuzzy inference. By the experimental results of two types of electric lines and sleeves, these proposed discrete event control and neural network learning algorithm are confirmed very effective to the insertion tasks of electric lines to sleeves as a typical task of active electric power maintenance tasks.

Performance Evaluation of a Mixed-Mode Type ER Engine Mount (I);Manufacturing and Test of Engine Mount (복합모드형 ER엔진마운트의 성능평가 (I);엔진마운트의 제작 및 시험)

  • Choe, Yeong-Tae;Choe, Seung-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.370-377
    • /
    • 2000
  • This paper presents a mixed-mode type ER(electro-rheological) engine mount, and its vibration control performance for a passenger vehicle is presented. The field-dependent yield stress of a transfo rmer oil-based ER fluid is empirically distilled in both shear and flow modes. This is then incorporated with the governing equation of motion of the proposed mixed-mode(shear mode plus flow mode) type engine mount. The damping force is analyzed with respect to the intensity of the electric field and design parameters such as electrode gap. Subsequently, the ER engine mount which is equivalent to the conventional hydraulic engine mount in terms of the damping level is designed and manufactured. Both computer simulation and experimental test are undertaken in order to evaluate vibration isolation performance. In addition, this performance is compared with that of the conventional hydraulic engine mount.

Static and Dynamic Characteristics of Electro - hydraulic Proportional Throttle Control Valve (전자 유압식 비례 교축 제어 밸브의 특성)

  • 오인호;이일영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.87-99
    • /
    • 1993
  • Nowadays, the cartridge valve can be controlled proportionally in remote place by adopting proportional solenoid and it becomes widely used as control component in hydraulic systems. Especially, multi stage proportional valve is attractive because it consumes less input power though its characteristics might slightly be defected. But, the system parameter should be carefully chosen to obtain optimistic characteristics. This study concerning three stage proportional throttle control valve is purposed to examine the influences of paameters to the dynamic characteristics. The typical transient and frequency responses of proportional throttle control valve were inspected through the experiments and compared to those derived from the theoritical analyses. And it was confirmed that the analyses are appropriate. Then the influences of various system parameters to the dynamic characteristics were examined by means of simulations. For the analyses, the basic equations derived from lumped model were linearized and the linearized equations were transformed to the transfer functions between inputs and outputs. Then the transient responses and frequency responses were obtained from transfer functions. 1. It is appropriate to estimate the dynamic characteristics of valve which has relatively sophisticated structure by means of system analyses using linearized equations. 2. Though the valve has two pilot stages, fairly good characteristics can be obtained by carefully choosing system parameters. 3. Main valve very quickly follows the movement of second pilot valve when the parameters of main valve(the oil supply passage and discharge passage fpr second pilot valve) are appropriately chosen.

  • PDF