• Title/Summary/Keyword: Electrical signals

Search Result 2,556, Processing Time 0.027 seconds

Location and Frequency Domain Detection of Corona Discharge Point in Oil Using AE Sensor (AE센서를 이용한 유중 코로나방전점 위치 및 주파수 영역 검출)

  • 이상우;김성훈;김인식;김기채;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.127-131
    • /
    • 1999
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane electrode was analyzed to determine the proper ultrasonic sensor. We also examined the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] AC high-voltage in oil. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were found to be 130[kHz] by the fast fourier transform. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages. Also the detection of corona discharge point location by AE signals was found to be possible by using two sensors.

  • PDF

Pulse Code Signal Recognition using Integra-Normalizer (인테그라-노말라이저를 이용한 펄스코드 신호인식)

  • Kim, Seong-Su
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.8
    • /
    • pp.491-494
    • /
    • 2000
  • A scheme is proposed for measuring similarities between the binary pulse signals in the pulse-code modulation using the Integra-Normalizer. The Integra-Normalizer provides a better interpretation of the relationship between the pulse signals by removing redundant codes, which maps all possible observed signals to one of the codes to be received with relative similarities between each pair of compared signals. The proposed method provides better error tolerance than L2 metric, such as Hamming distance, since the distances between pulse signals are measured not useful for the time-delay detection in the pulse-code modulation.

  • PDF

Ultrasonic Signal Characteristics of Corona Discharges in Air (공기중 코로나방전의 초음파신호 특성)

  • Lee, Sang-Woo;Kim, In-Sik;Lee, Kwang-Sik;Lee, Dong-In;Lee, Dong-Heoon;Bae, Sang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1702-1704
    • /
    • 1998
  • In order to establish the usefulness of ultrasonic techniques for detecting corona discharges in high-voltage power apparatus, it is first necessary to determine the relationship between electrical and ultrasonic signals of corona discharges in air. In this paper, various characteristics of ultrasonic signal detection for point-to-plane corona discharges using a 200[kHz] ultrasonic sensor are examined. In regard to the attenuation and directivity of ultrasonic signals, the signals were inversely proportional to the distance between corona sources and ultrasonic receiving sensors, and half attenuation angles were approximately 7.0 degree. Ultrasonic signals of positive polarities were first obserbed at corona inception voltages. and the signals were increased with increasing the applied voltages.

  • PDF

Surface Plasmon Resonance Multisensing Using Thickness Difference of Additional Layer (부가층의 두께 차이를 이용한 표면플라즈몬공명 멀티센싱)

  • Kim, Young-Gyu;Oh, Myung-Hwan;Lee, Seung-Ki
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.10
    • /
    • pp.492-498
    • /
    • 2006
  • A novel surface plasmon resonance(SPR) multisensing method, which does not require imaging apparatus such as CCD, has been proposed and implemented experimentally. The proposed method is based on the multichannel SPR and the separation of signals by use of additional layers whose thickness is controlled. SPR signals are influenced by the thickness of sensing layer as well as the optical condition of sensing surface. As the SPR signals from different ligands are usually positioned closely, the reflected light from sensing surface does not provide us with the clear differences of resonance signal depending on the kinds of ligands. It was found from our experiments that SPR signals from each ligand that is located on the additional layer with different thickness can be separated clearly enough to identify various signals from different ligands. Proposed method with theoretical design and simulation has been verified experimentally by using $SiO_2$ thin film layer as additional layer.

Analysis of Fault Diagnosis for Current and Vibration Signals in Pumps and Motors using a Reconstructed Phase Portrait

  • Jung, Young-Ok;Bae, Youngchul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.166-171
    • /
    • 2015
  • In this paper, we measure the current and vibration signals of one-dimensional time series that occur in a motor and pump, respectively. These machines are representative rotary and pumping machines. We also eliminate unnecessary components such as noise by pre-processing the current and vibration signals. Then, in order to diagnose fault signals for the pump and motor, we transform from one-dimensional time series to a two-dimensional phase portrait using Takens’ embedding method. After this transformation, we review the variation in the pattern according to the fault signals.

Diagnosis of Insulation Deterioration in Cast-Resin Power Transformer using Acoustic Emission Techniques (음향방출법에 의한 몰드형 전력변압기의 절연열화 진단)

  • 이상우;김인식;이동인;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, AE(Acoustic Emission) signals detected from the growth of the electrical tree in an epoxy resin under ac high-voltage application were analysed to diagnose the insulation deterioration of cast-resin power transformer. Frequency spectra of AE signals generated from the magnetizing and the load currents in the actual operating cast-resin power transformer of 500[kVA] under distribution system of 22.9[kV] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in the core of the transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals. The frequency spectra of AE signals generated from the cast-resin power transformer in operation due to both the magnetizing and the load currents appeared in the range of 40-120[kHz], but the frequency band of AE signals emitted from the void discharges in an epoxy resin sample was about 50[kHz] to 230[kHz].

  • PDF

Fatten Analysis of Trouble Signal on DS for GIS using Neural Network (신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석)

  • 김종서;이은석;천종철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1310-1315
    • /
    • 2003
  • GIS(Gas Insulated Switchgear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. But, because of structural characteristics, this is difficult to monitor externally and provide much loss in the event of an accident. Recently, because equipment of GIS is occurring problem of confidence used for a long time, development of diagnosis technique have been importantly recognized. therefore, measurement and analysis of PD much has been generally used for equipment of GIS. But, in case of measurement of PD at field, real trouble signals is difficult to classify noise. Accordingly, a variety of trouble conditions for DS are simulated, and detected signals are analyzed by the application of electrical and mechanical methods. For this analysis, detected signals are accumulated according to phase-magnitude with the application of induction sensor, and then we analyzed the characteristics. For the simulation experiment, we make DS for 170KV GIS and analyze the characteristics of detected signals with the application of neural network algorithm. last, we have measured DS for GIS at field, and then have analyzed detected signals.

A New Fault Diagnosis Scheme between L1 Signals Using IES on the Metric Defined via Kalman Filter and Exponential Function Transformation (칼만추정과 초월함수 사영을 통한 L1 신호간의 거리 Metric에 IES을 적용한 새로운 고장진단 기법)

  • Kim, Sung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.23-28
    • /
    • 2015
  • Measuring the distances between signals in the signal space is usually determined by obtaining the ideal metric which is not easy to obtain. In this research we have investigated the scheme that measures the distances between the signals constructed with the measured voltage signals connected to electric apparatus using Kalman filter and exponential mapping. The metric is defined on the feature signals obtained via the estimation process of a Kalman filter and the mapping process using the exponential transformation. Diagnosis is on the voltage fluctuations is applied to determining whether the system is in the stable state or not due to the unexpected accidents, such as power overcharge, discharge, outages flow may be the cause of the accident. The decision making scheme evaluated with respect to the effectiveness and the degree of complication with different variances. Two methods, the Hard Limit Threshold Scheme(HLTS) and the Interval Energy Scheme(IES) are proposed and compared. In experiments the IES shows better tolerance to impulse noise than the HLTS.

A QRS pattern analysis algorithm by improved significant point extraction method (개선된 특성점 검출 기법에 의한 QRS 패턴해석)

  • Hwang, Seon-Cheol;Lee, Byung-Chae;Nam, Seung-Woo;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.51-55
    • /
    • 1991
  • This paper describes an algorithm of pattern analysis of ECG signals by significant points extraction method. The significant points can be extracted by modified zerocrossing method, which method determines the real significant point among the significant point candidates by zerocrossing method and slope rate of left side and right side. This modified zerocrossing method improves the accuracy of detection of real significant point position. This paper also describes the pattern matching algorithm by a hierarchical AND/OR graph of ECG signals. The decomposition of ECG signals by a hierarchical AND/OR graph can make the pattern matching process easy and fast. Furthermore the pattern matching to the significant points reduces the processing time of ECG analysis.

  • PDF

Wavelet Transforms: Practical Applications in Power Systems

  • Akorede, Mudathir Funsho;Hizam, Hashim
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.168-174
    • /
    • 2009
  • An application of wavelet analysis to power system transient generated signals is presented in this paper. With the time-frequency localisation characteristics embedded in wavelets, the time and frequency information of a waveform can be presented as a visualised scheme. This feature is very important for non-stationary signals analysis such as the ones generated from power system disturbances. Unlike the Fourier transform, the wavelet transform approach is more efficient in monitoring fault signals as time varies. For time intervals where the function changes rapidly, this method can zoom in on the area of interest for better visualisation of signal characteristics.