건축물의 등전위 본딩 및 전기적 연속성 평가 (Assessment of Equipotential Bonding and Electrical Continuity in Buildings)

  • 길형준;김동우;김동욱;이기연;문현욱;김향곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.385-386
    • /
    • 2009
  • This paper deals with assessment of equipotential bonding and electrical continuity in Buinding by investigation on the spot at construction site. The assessment was carried out for continuity of steelwork in reinforced concrete structure, bonding conductor, protective conductor. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding, use of surge protective device.

  • PDF

친환경자동차의 인체 안전을 위한 전기적 연속성 측정 연구 (Study on the Electric Continuity Measurements of Green Car for Human Body Safety)

  • 김향곤;이기연;김동욱;최효상
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.351-356
    • /
    • 2009
  • In this study, we analyzed and experimented about electric continuity for human body safety from green cars. And we compared power systems of HEV and examined about human body effect of current and time. We investigated internal and external standards and regulations for human body safety from high voltage electrical equipments. Indirect contact refers to contact between the human body and exposed conductive parts. According to UNECE R100, ISO 23273-3, ISO 6469-3 and Japanese Regulation Attachment 101, electric continuity between any two exposed conductive parts shall not exceed $0.1{\Omega}$. The value of electric continuity was measured below $0.1{\Omega}$ at the actual condition of green car. We expected that the results of these experiments can utilize to data for electrical safety of green car.

피뢰설비현장의 접지 및 전기적 연속성 시험에 따른 표준적용 (The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field)

  • 송길목;구경완
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.583-588
    • /
    • 2014
  • In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.

철근콘크리트 아파트의 철근구조체에 대한 전기적 연속성 평가 (Evaluation of Steelwork Continuity within Reinforced Concrete Apartment Structures)

  • 이기홍;이택섭;김언석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2005
  • This paper conducted to evaluate electrical continuity of steelworks within reinforced concrete apartment structures as the down conductor in external lightning protection system. The reinforcing bars in reinforced concrete structures can be used as the down conductor when their overall electrical resistance is not greater than the resistance value of 0.2 ohm between the uppermost part and the ground level. According to the results of electrical resistances measured by 4-terminal low resistance measurements, the steelworks in reinforced concretes structures exhibited the electrical continuity with low electrical resistance.

  • PDF

G2 Continuity Smooth Path Planning using Cubic Polynomial Interpolation with Membership Function

  • Chang, Seong-Ryong;Huh, Uk-Youl
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.676-687
    • /
    • 2015
  • Path planning algorithms are used to allow mobile robots to avoid obstacles and find ways from a start point to a target point. The general path planning algorithm focused on constructing of collision free path. However, a high continuous path can make smooth and efficiently movements. To improve the continuity of the path, the searched waypoints are connected by the proposed polynomial interpolation. The existing polynomial interpolation methods connect two points. In this paper, point groups are created with three points. The point groups have each polynomial. Polynomials are made by matching the differential values and simple matrix calculation. Membership functions are used to distribute the weight of each polynomial at overlapped sections. As a result, the path has $G^2$ continuity. In addition, the proposed method can analyze path numerically to obtain curvature and heading angle. Moreover, it does not require complex calculation and databases to save the created path.

3차원 와전류문제의 유한요소해석에서 쿨롱게이지조건과 전류연속조건의 영향 (Effects of Coulomb Gauge Condition and Current Continuity Condition on 3-Dimensional FE Analysis for Eddy Current Problems)

  • 이향범
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권10호
    • /
    • pp.483-491
    • /
    • 2005
  • To solve the 3D eddy current problems by using FE(finite element) method with MVP(magnetic vector potential) and electric scalar potential, Coulomb gauge condition and current continuity condition have to be considered. Coulomb gauge condition enforced on existing FE formulations to insure the uniqueness of MVP looks unnatural and current continuity condition which can be driven from Ampere's law looks unnecessary. So in this paper the effect of two conditions on FE formulations are investigated in order to help to obtain accurate numerical simulation results.

放射線이 照射된 MIS capacitor의 電荷 蓄積 및 flat band 전압 이동에 대한 實驗 및 數値的 硏究 (Experiments & numerical analysis of charge accumulation and flat band voltage shifts in irradiated MIS capacitor)

  • 황금주;김홍배;손상희
    • 대한전기학회논문지
    • /
    • 제44권4호
    • /
    • pp.483-489
    • /
    • 1995
  • To investigate the mechanism generated by irradiation in the insulator layer irradiated MIS (Metal - Insulator - Semiconductor) device, the various types of MIS capacitors depending on insulator thickness, insulator types and implanted impurities are fabricated on the P-type wafer. MIS capacitors exposed by 1Mrad Co$^{60}$ .gamma.-ray are measured for flat band voltage and charge density shifts pre- and post-irradiation. The measuring results of post-irradiation show the flat band voltage shifting toward negative direction and charge density increasing regardless of parameters. This results have a good agreement with calculated data by computer simulation. Si$_{3}$N$_{4}$ layers have a good radiation-hardness than SiO$_{2}$ layers compared to the results of post-irradiation. Also, radiation-induced negative trap is discovered in the implanted insulator layer. Using numerical analysis, four continuty equations (conduction-band electrons continuity equation, valence-band holes continuity equation, trapped electrons continuity equation, trapped holes continuity equation) are solved and charge distributions according to the distance and Si-Insulator interface states are investigated.

  • PDF

지중송전계통 병행지선 설치 방안 검토 (Analysis of Installation Methods of Earth Continuity Conductor on Underground Power Cable Systems)

  • 강지원;정채균;윤형희;윤종건;김두진;김재승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.468-469
    • /
    • 2008
  • In this paper, the effects of earth continuity conductor are deeply analyzed for reducing the level of induced sheath voltage at the single point bonded sections. The various installation conditions of an earth continuity conductor are considered including conductor dimensions, its spacing from the three phase cables, and utilization of two earth continuity conductors when the grounding fault occurs on real power cable systems. Finally, the transient characteristics including reduction effects of induced sheath voltage are proved by EMTP simulations. The optimal installation condition of earth continuity conductor is also proposed based on those results.

  • PDF

인하도선으로 활용하기 위한 철근콘크리트구조물의 전기 및 기계적 소요 특성에 대한 실험적 검증 (Experimental Verification on the Use of Steelwork as a Down-Conductor in Lightning Protection System)

  • 이기홍
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.94-99
    • /
    • 2011
  • This paper verified the characteristics of electrical continuity and mechanical strength of steelwork required to use it as a down-conductor in lightning protection system. It was proven that the steelwork in reinforced concrete apartment has an excellent electrical continuity with low resistance(less than 0.2[${\Omega}$].). But it was confirmed that a poor connection between two reinforcement bars can easily cause serious damages of the concrete even with the impulsive current of 50[kA], 10/350[${\mu}s$]. These results of experiments mean that the additional measures are necessary in using the steelwork as the down-conductor of the lightning protection system.

Numerical Analysis Using Finite Element Method On Phosphorescent Organic Light Emitting Diodes

  • Hwang, Y.W.;Lee, H.G.;Won, T.Y.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권1호
    • /
    • pp.29-33
    • /
    • 2014
  • In this paper, we report our numerical simulation on the electronic-optical properties of the phosphorescent organic light emitting diodes (PHOLEDs) devices. In order to calculate the electrical and optical characteristics such as the transport behavior of carriers, recombination kinetics, and emission property, we undertake the finite element method (FEM). Our model includes Poisson's equation, continuity equation to account for behavior of electrons and holes and the exciton continuity/transfer equation. We demonstrate that the refractive indexes of each material affect the emission property and the barrier height of the interface influences the behavior of charges and the generation of exciton.