• 제목/요약/키워드: Electrical apparatus

검색결과 694건 처리시간 0.021초

고온초전도 기기응용을 위한 모의 \ulcorner치 환경에서 액체질소의 절연파괴 특성 (Electrical Breakdown Characteristics of LN2 under Simulated Quenching Conditions for Application of HTS Apparatus)

  • 백승명;정종만;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.985-990
    • /
    • 2002
  • The electrical breakdown characteristics of liquid nitrogen(LN$\sub$2/) were studied under simulated quenching conditions for application of HTS apparatus. The experimental results for various quenching condition revealed that the breakdown voltage of LN$\sub$2/ with bubble flow velocity and gap spacing. In the case, breakdown voltage decreases gradually with the bubble velocity. When it is bubble velocity from 0 to 1 $\ell$ /min, breakdown voltage rapidly decreases but decreases from 2 $\ell$/min to 10 $\ell$/min slowly. The breakdown voltage for vertical electrode arrangement is higher than that for horizontal electrode arrangement. Also, it did a electric field and potential distribution interpreting at the liquid nitrogen when the bubble existed. The plots of equipotential lines for three cases are also shown.

설계변수 매개화를 이용한 전기기기 최적설계 (Optimum Design of Electrical Apparatus Using Design Variable Parametrization)

  • 이형범;박일한;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권11호
    • /
    • pp.546-555
    • /
    • 2001
  • ln this paper, the optimum design of electrical apparatus using design variable parametrization is presented. For analysis and design, the finite element method and the design sensitivity method is used, respectively. By applying the parametrization of the design variables, the obtained designed shape is continuous and smooth. For the parametrization the Bezier spline is used. The designed shape with parametrization is characterized by the control points. By delivering control points to the commercial CAD packages or NC machines, the exact designed shape can be realized in the manufacturing the electrical apparatus. The designed results with and without parametrization are compared and the validity of the parametrization is verified.

  • PDF

능동열시험법을 이용한 몰드변압기 진단 (Diagnostic of Cast Resin Using Active Infrared Thermal Testing Method)

  • 임용배;정승천
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.481-484
    • /
    • 2004
  • A form of measured temperature distribution to estimate condition of a electrical apparatus is a absolute reference for condition of the apparatus, time rate of transition, and difference between reference and currently temperature. Because passive thermography which has not injection of external thermal stimulation shows difference of temperature being on surface of a structure and temperature difference between the structure and back ground, the result could apply only to estimation or monitor for condition of terminal relaxation and overload related with temperature rising. However, a thermal flow in active thermography is differently generated by structure and condition of surface and subsurface. This paper presents the nondestructive testing using the properties and includes the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

사고전류 인가 시 초전도선재의 상전도-초전도 접합부가 통전전류와 ?치저항에 미치는 영향 (Effect on the Transport Current and Quench Resistance of the HTS Wire with Normal-Superconducting Junction During the Fault Current Applying)

  • 홍공현;두호익;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.625-629
    • /
    • 2015
  • The second-generation HTS wire its YBCO coated conductor is widely used in the superconducting power apparatus. The YBCO coated conductor uses the normal-superconducting junction to increase the transport capacity of superconducting power apparatus when it is applied. The normal-superconducting junction can be a cause of reducing the stability of the superconducting power apparatus when a fault current is applied. Thus, in this study we have conducted the effect analysing normal-superconducting junction for the fault current using transport current and quench resistance. From the experimental results when a fault current is applied, the effect on the normal-superconducting junction is reduced the larger the amplitude of the fault current and is helpful to maintain the thermal stability of the HTS wire.

초전도 기기의 전기절연 (Electrical Insulation for Superconducting Apparatus)

  • 곽동주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1989년도 춘계학술대회 논문집
    • /
    • pp.11-14
    • /
    • 1989
  • Some experimental studies on the dielectric strength characteristics of organic material under compressive stress associated with high magnetic fields and of liquid coolant in the presence of thermally induced bubble, which might be generated at unexpected quench of immersed-cooling superconducting devices, was performed to obtain the basic data on the electrical insulation design for superconducting apparatus. PET and liquid nitrogen were used as test mediums.

  • PDF

635nm 레이저다이오드의 피부 결손 치유 효과 (Healing Effect of 635 nm Laser Diode in Skin Injury)

  • 천민우
    • 한국전기전자재료학회논문지
    • /
    • 제21권7호
    • /
    • pp.674-678
    • /
    • 2008
  • Low level laser therapy has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 635 nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. In this study, the designed device was used to find out how 635 nm laser diode affected the skin injury of SD-Rat(Sprague-Dawley Rat). We divided the participants into two groups; irradiation group which was irradiated 10 minutes a day for 9 consecutive days, and none irradiation group. The results showed that the study group had lower incidence of inflammation and faster recovery, compared with the control group.

조립과 확장이 가능한 반도체 제조용 기판 가열 장치 (An Assemble and Expandable Substrate Heating Apparatus for the Semiconductor Manufacturing)

  • 정순원;구경완
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.67-71
    • /
    • 2009
  • This research is a new structure of the semiconductor substrate heating apparatus in which the assembly and expansion are possible. The fast thermo-responsive according to the direct heating structure of the heating plate layer adhering closely to the floor side of a substrate and the fast heat loss minimization can be accomplished. Moreover, the contact area of the sheath heater, which is the heating plate layer built-in heating apparatus, is increased, so that it has more heating valid area. There is no problem with the deformation interpreted in the state where it assembles the block of a several of the simulation result structure, the safety, and the stress. In addition, it is confirmed that building a large-size heating block is possible since the temperature deflection of the manufactured plate is lower than the standard value.

유무효전력설비의 적소투입을 통한 전력손실개선 (System Loss Improvement through Proper Location of Active and Reactive Power Apparatus)

  • 이상중
    • 조명전기설비학회논문지
    • /
    • 제14권3호
    • /
    • pp.77-80
    • /
    • 2000
  • 본 논문은 有無效 섣둡jJ設觸의 投貴위치와 그 용향을 적정화하여 동일한 설비투자량에 대하여 전력손실을 최소화하는 방안에 대하여 설명하였다. 유효 및 무효전릭의 미소증분에 대한 손실의 변화를 나타내는 모선의 손실감도를 소개하고 전력송실을 최대한 개선하기 워한 유무효전력 설비의 투자지표로 이용하였다. 각 모선에 주어지는 투자지표의 우선순위에 따라 유효 및 무효전력설비가 투자되어 전력손실을 최소화한다.

  • PDF

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

염진해 오손도 자동측정장치 (Automatic Measuring Apparatus for Salt and Dust Contamination)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF