Browse > Article
http://dx.doi.org/10.4313/JKEM.2002.15.11.985

Electrical Breakdown Characteristics of LN2 under Simulated Quenching Conditions for Application of HTS Apparatus  

백승명 (경상대학교 전기공학과 및 컴퓨터 - 자동화응용 기술 연구소)
정종만 (경상대학교 전기공학과 및 컴퓨터 - 자동화응용 기술 연구소)
김상현 (경상대학교 전기공학과 및 컴퓨터 - 자동화응용 기술 연구소)
Publication Information
Journal of the Korean Institute of Electrical and Electronic Material Engineers / v.15, no.11, 2002 , pp. 985-990 More about this Journal
Abstract
The electrical breakdown characteristics of liquid nitrogen(LN$\sub$2/) were studied under simulated quenching conditions for application of HTS apparatus. The experimental results for various quenching condition revealed that the breakdown voltage of LN$\sub$2/ with bubble flow velocity and gap spacing. In the case, breakdown voltage decreases gradually with the bubble velocity. When it is bubble velocity from 0 to 1 $\ell$ /min, breakdown voltage rapidly decreases but decreases from 2 $\ell$/min to 10 $\ell$/min slowly. The breakdown voltage for vertical electrode arrangement is higher than that for horizontal electrode arrangement. Also, it did a electric field and potential distribution interpreting at the liquid nitrogen when the bubble existed. The plots of equipotential lines for three cases are also shown.
Keywords
Electrical breakdown; Liquid nitrogen; Quenching conditions; HTS apparatus;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Patrial and complete electrical breakdown in simulated high temperature superconducting coils /
[ B. Y. Seok;H. Komatsu;J. Suehiro;M. Hara ] / IEEE Trans. on Dielectrics and Electrical Insulation   DOI   ScienceOn
2 Generation of bubbles in liquid argon and nitrogen in divergent electric fields /
[ A. Dentat;F. Jomni;F. Aitken;N. Bonifaci ] / Proceedings of 13th International Conference on Dielectric Liquids(ICDL '99)
3 Qualification results of a 50 m-115 kV warm dielectic cable system /
[ M. Nassi;N. Kelley;P. Ladie;P. Corsaro;G. Ciletta;C. Von Dollen ] / IEEE Trans. on Appl. superconductivity   DOI   ScienceOn
4 극저온 액체의 동적 절연파괴 특성 /
[ 김상현;김현희;김영석;정종만;정순용 ] / 한국전기전자재료학회논문지   과학기술학회마을
5 Electrical insulation characteristic of supercinducting power apparatus /
[ M. Hara;H.Okubo ] / Cryogenics   DOI   ScienceOn
6 액체 질소의 절연 특성에 미치는 전극효과에 관한 연구 /
[ 김상현;김정호;윤문수;권영한 ] / 한국전기전자재료학회논문지   과학기술학회마을
7 0.7 MJ UPS용 초전도 케이블의 ??치 특성 /
[ 류경우;김해종 ] / 한국전기전자재료학회논문지   과학기술학회마을
8 Cryogenic liquids-aprospective insulation basis for future power equipment /
[ J. Gerhold ] / IEEE Trans. on Dielectrics and Electrical Insulation   DOI   ScienceOn
9 High voltage insulation performance of cryogenic liquids for superconducting power apparatus /
[ H. Okubo;M. Hikita;H. Goshima;H. Sakakibari;N. Hayakawa ] / IEEE Trans. on Power Delivery   DOI   ScienceOn
10 630kVA high temperature superconductiong transformer /
[ H. Zueger ] / Cryogenics   DOI   ScienceOn