• Title/Summary/Keyword: Electrical Installation

Search Result 6,502, Processing Time 0.112 seconds

Comparison Analysis of Soil Structure Methods for Deciding the Position of a Deeply Driven Ground Rod (심매설 접지봉의 위치결정을 위한 대지구조 분석 방법들의 비교분석)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.37-45
    • /
    • 2007
  • Recently, there has been an increase of the use of ground system for lightning protection called deeply driven grounding electrode. In the case of deeply driven grounding electrode, the rod electrode is equipped perpendicularly and deeply, therefore, it has a benefit to have less restriction of place compared to mesh grid electrode. However, ground impedance is largely changed by the local earth resistivity, so it requires a detailed analysis of the ground structure when planning. The measurement of earth resistivity by existing Wenner's method has been widely used, however, this method can not find out a change in the local ground resistance and it shows the result outwardly to be difficult to estimate exact depth. Therefore, this study analyzed the ground structure as 2-D image using 96 channels measurement facility and tried to analyze change in the local ground resistance and depth of the ground in order to design a deeply driven electrode effectively for lightning protection. It used Wenner alpha method dipole-dipole method and Schlumberger method for 2-D image analysis of the ground resistivity ma based on, it the result was compared with the ground structure analyzed with the result using the CDEGS and Wenner 1-D method.

An Optimal Location of Superconducting Fault Current Limiter in Distribution Network with Distributed Generation Using an Index of Distribution Reliability Sensitivity (신뢰도 민감도 지수를 이용한 복합배전계통 내 초전도한류기의 최적 위치에 관한 연구)

  • Kim, Sung-Yul;Kim, Wook-Won;Bae, In-Su;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.52-59
    • /
    • 2010
  • As electric power demand of customers is constantly increasing, more bulk power systems are needed to install in a network. By development of renewable energies and high-efficient facilities and deregulated electricity market, moreover, the amount of distributed resource is considerably increasing in distribution network consequently. Also, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. These changes make fault current increase. Therefore, the fault current will exceed a circuit breaker capacity. In order to solve this problem, replacing breaker, changing operation mode of system and rectifying transformer parameters can be taken into account. The SFCL(Superconducting Fault Current Limiter) is one of the most promising power apparatus. This paper proposes a methodology for on optimal location of SFCL. This place is defined as considering the decrement of fault current by component type and the increment of reliability by customer type according to an location of SFCL in a distribution network connected with DG(Distributed Generation). With case studies on method of determining optimal location for SFCL applied to a radial network and a mesh network respectively, we proved that the proposed method is feasible.

A Study of Autonomous Intelligent Load Management System Based on Queueing Model (큐잉모델에 기초한 자율 지능 부하 관리 시스템 연구)

  • Lee, Seung-Chul;Hong, Chang-Ho;Kim, Kyung-Dong;Lee, In-Yong;Park, Chan-Eom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.134-141
    • /
    • 2008
  • This paper presents an innovative load management technique that can effectively lower the summer peak load by adjusting the aircondition loads through smoothe coordinations between utility companies and large customers. An intelligent hierarchical load management system composed of a Central Intelligent Load Management System(CIMS) and multiple Local Intelligent Management Systems(LIMS) is also proposed to implement the reposed technique. Upon receiving a load curtailment request from the utilities, CIMS issues tokens, which can be used by each LIMS as a right to turn on the airconditioner. CIMS creates and maintains a queue for fair allocation of the tokens among the LIMS demanding tokens. By adjusting the number tokens and queue management Policies, desired load factors can be achieved conveniently. The Markov Birth and Death Process and the Balance Equations are employed in estimating various queue performances. The proposed technique is tested using a summer load data of a large apartment complex and proved to be quite effective in load management while minimizing the customer inconveniences.

Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique (반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘)

  • Park, Kye-In;Chang, Sang-Hoon;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.71-79
    • /
    • 2008
  • High voltage distribution lines in the electric railway system placed according track with communication lines and signal equipments. Case of the over head lines is occurrence the many fault because lightning, rainstorm, damage from the sea wind and so on. According this fault caused protection device to wrong operation. One line ground fault that occurs most frequently in railway high voltage distribution lines and sort of faults is line short, three line ground breaking of a wire, and so on. For this reason we need precise maintenance for prevent of the faults. The most important is early detection and fast restoration in time of fault for a safety transit. In order to develop an advanced fault location device for 22.9[kV] distribution power network in electric railway system this paper deals with new fault locating algorithm using flow technique which enable to determine the location of the fault accurately. To demonstrate its superiorities, the case studies with the algorithm and the fault analysis using PSCAD/EMTDC (Power System Computer Aided Design/Electro Magnetic Transients DC Analysis Program) were carried out with the models of direct-grounded 22.9[kV] distribution network which is supposed to be the grounding method for electric railway system in Korea.

Discharge Luminous Phenomena Caused Between ZnO Surge Arrester Block and Electrodes (산화아연 피뢰기 소자와 전극사이에 발생하는 방전광 현상)

  • Lee, Bok-Hee;Park, Keon-Young;Kang, Sung-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.44-50
    • /
    • 2005
  • This paper deals with the characteristics and reduction methods of the plasma luminosity caused between the ZnO surge arrester block and metal electrodes. In this study, the impulse current generator that can generate $8/20[{\mu}s]$ impulse currents with a peak short-circuit of 10[kA] is designed and fabricated. Plasma luminosity phenomena for fine and used ZnO blocks were observed as a function of the contact states between the ZnO block and electrodes and the polarity of applied impulse voltages. As a result, discharge luminous events are produced near the contact edges between the ZnO block and metal electrodes. The discharge plasma luminosity between the ZnO surge arrester block and low potential electrode is more intensive than that between the ZnO surge arrester block and high potential electrode. Surface flashover of ZnO blocks are mainly caused by plasma generation near the edge of metal electrode. Also, plasma luminosity for the fine ZnO blocks is less than that for the used ZnO blocks. Plasma luminosity at the contact of the ZnO block and ring-type electrode is more intensive than that at the contact of ZnO block and disk electrode. It is desirable to use the disk electrode with the proper contact area to reduce the plasma luminosity caused at the contact point between the ZnO block and electrodes.

A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure (2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구)

  • Lee, Woo-Cheol;Yoo, Dong-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • This paper presents a three phase Line-Interactive uninterruptible power supply(UPS) system with dual converter structure. The three phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator, which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low total harmonic distortion(THD). This paper presents in the series and parallel active compensator charging method depending on the amplitude of the source voltage. The conventional Line-Interactive UPS system is responsible for the DC charging and output voltage regulation at the same time, but UPS system with dual converter structure, a series active compensator can also charge the DC link. Therefore the charging algorithm using the series and parallel compensator needs to be researched. Therefore, by making the DC link voltage stable it can contribute the stability of series and parallel compensator. The simulation and experimental result are depicted in this paper to show the effect of the proposed algorithm.

Measurements of Fast Transient Voltages due to Human Electrostatic Discharges (인체에 대전된 정전기 방전에 의해 발생한 급속과도전압의 측정)

  • 이복희;이동문;강성만;엄주홍;이태룡;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.108-116
    • /
    • 2002
  • This paper presents the measurements and evaluation of voltage waveforms due to human electrostatic discharge(ESD). The principle of operation and design rule of a new device for measuring the ESD fast transient voltages with very fast rise time were described. Peak values and rise time of ESD voltages derived from a charged human body under a variety of experimental conditions were examined. The frequency bandwidth of the proposed voltage measuring system ranges from DC to 400[㎒]. The ESD voltage waveform is nearly equal to the ESD current waveform and the peak amplitude of ESD current waveform is roughly proportional to the ESD voltage in each experimental conditions. A rapid approach results in a discharge voltage with a faster initial rise time than for a slow approach. The voltages caused by direct finger ESDs have an initial slope with a relatively long, 10∼30[ns] rise time, but the amplitude is small. On the other hand, the voltages caused by direct hand/metal ESDs have a steep initial s1ope with 1 ∼3[ns] rise time, but an initial spike is very big. As a consequence, it was found that the ESD voltage and current waveforms strongly depend on the approach speed and material of intruder. These measurement results would be useful to design the ESD protective devices.

A Study on the improvement of Chemicals Dosing Performance using Neural network in a Purification Plant (신경회로망을 이용한 상수처리설비의 약품주입 성능개선에 관한 연구)

  • 류승기;최도혁;홍규장;문학룡;한태환;유정웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.104-113
    • /
    • 1998
  • In genral, the water process facilities include the purification plant, the waste water plant and the process of this purification plant is consisted of the intake, coagulation, settling, filtration, disinfection. The coagulation is very important in filtration processing plant and is very related to process of turbidity. The coagulation to the turbidity is, however, not yet to be clarified and the amount of coagulant can not be easily calculated. Moreover the coagulant dosing amount has to be decided adaptively according to the qualities of the raw water. So, the automation of chemicals dosing process and the supervisory system were needed to improve the performance of facilities. In this paper, a neural network is employed to model the coagulation to the turbidity of the treated water and the historical jar-test data are used to train the neural network. And also, an automation system to support the coagulant dosing process using the neural network was implemented and was shown by the field test. This automation system for the operator support system was constructed the environment to supervise the state an management of facilities for the maintenance.

  • PDF

Characteristics of the Flux-lock Type Superconducting Fault Current Limiter According to the Iron Core Conditions (자속구속형 초전도 전류제한기의 철심조건에 따른 특성)

  • Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Cho, Guem-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.38-45
    • /
    • 2006
  • The superconducting fault current limiters(SFCLs) provide the effect such as enhancement in power system reliability due to limiting the fault current within a few miliseconds. Among various SFCLs we have developed a flux-lock type SFCL and exploited a special design to effectively reduce the fault current according to properly adjustable magnetic field after the short-circuit test. This SFCL consists of two copper coils wound in parallel on the same iron core and a component using the YBCO thin film connected in series to the secondary copper coil. Meanwhile, operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. To analyze the operational characteristics, we compared closed-loop with open-loop iron core. When the applied voltage was 200[Vrms] in the additive polarity winding, the peak values of the line current the increased up to 30.71[A] in the closed-loop and 32.01[A] in the open-loop iron core, respectively. On the other hand, in the voltages generated at current limiting elements were 220.14[V] in the closed-loop and 142.73[V] in the opal-loop iron core during first-half cycle after fault instant under the same conditions. We confirmed that the open-loop iron core had lower power burden than in the closed-loop iron core. Consequently, we found that the structure of iron core enabled the flux-lock type SFCL at power system to have the flexibility.

A Study on Driver's Perception over the Change of the Headlamp's Illuminance : 3. Driver's psychological property (전조등 조도변동에 대한 운전자의 인식연구 : 3. 운전자의 심리적 특성)

  • Kim, Huyn-Ji;Kim, Hyun-Jin;Kim, Gi-Hoon;Kim, Hoon;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.19-26
    • /
    • 2006
  • In this study, psychological assessment was carried out to investigate the driver's psychological characteristics by the change of the headlight. The participants were 20 men and 20 women in their 20s and thirty-two different conditions in combinations of waveform of light, voltage, and alteration time were used. The questionnaire for the assessment was evaluated by 8 subjective item and 5-point SD criteria of 19 pair's adjective. The results were as follows : 1. The assessment results from SD method indicated 4 factors by factor analysis, and it was shown that A waveform had significances in a sense of security and impetus and B waveform had a significance in a sense of security. The levels of the limitations for the voltage change were 12[V] in the factor of a sense of security and 11[V] in the factor of a sense of impetus for A waveform, 12.6[V] in the factor of a sense of security for B waveform. 2. The results of the subjective assessment showed that the limitation of A waveform's brightness change was 12[V]. Moreover, the limitations of voltage changes were 12.67[V] for B waveform brightness change, 12.12[V] for discomfort, 12.71[V] for darkness. And the limitation of C waveform's brightness change was 12[V].