• Title/Summary/Keyword: Electric-Shock

Search Result 407, Processing Time 0.03 seconds

Effect of lead intoxication and thiamine deficiency on myelin compositions and seizure threshold in the rats.

  • Cheong, Jae-Hoon;Ryu, Jae-Ryeon;Lee, Sang-Derk;Ko, Kwang-Ho
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1995.04a
    • /
    • pp.96-96
    • /
    • 1995
  • It was recognized that lead intoxication reduces thiamine content in the brain of rat and this change produces the alterations of thiamine-related biochemical reactions. In the present study, it was tested whether the changes of myelin composition as well as seizure threshold induced by lead intoxication in rats may be related to these changes of thiamine status and thiamine related biochemical factors. Wistar rats were divided into five groups: Control group, Lead-treated group, Lead plus Thiamine-treated group, Thiamine-deficient group, Pyrithiamine-treated group. Each group was divided into three subgroups: 3, 7 and 16 week old group. Myelin protein and phospholipid, one of the compositions of myelin lipid, were measured in the myelin isolated from rat brain. Threshold of electric shock seizure was tested in each group. The amount of each myelin composition in lead-treated group and thiamine-deficient group was significantly lower than those of all the brains in control group, but recovery by supplementation with thiamine during lead intoxication was occurred only in the cerebellum of 3 week old animal. Thresholds of the electric shock seizure of lead treated group and thiamine deficient group in 3 and 7 week old rats were significantly lower than those of control group, while those of lead plus thiamine treated group were similar to those of control group.

  • PDF

Development of Electrohydraulic Forming Apparatus and Its Experimental Study (액중 방전 성형의 실험 장치 개발 및 실험적 연구)

  • Woo, Mina;Noh, Hakgon;Song, WooJin;Kang, Beomsoo;Kim, Jeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.2
    • /
    • pp.236-241
    • /
    • 2017
  • Electrohydraulic forming is a high-speed forming process that deforms a blank using electric discharge in liquid. When high voltage is discharged in the water, a shock wave is propagated from the tip of the electrodes to the blank, causing the blank to be deformed into the die. Electrohydraulic forming has many advantages including improved formability and reduced bouncing effect and springback. The objective of this paper was to conduct a feasibility study to identify the electrohydraulic effect. An electrohydraulic forming apparatus was developed and experiments were carried out. The results of the experiment showed that the developed apparatus had sufficient energy to deform the blank into the die. Using the hole to emit residual air in the die was more effective than using the vacuum pump in terms of saving on experiment time.

Characteristic Analysis and Configuration of the Protection System to Improve the Safety of the BIPV System (BIPV 시스템의 안전성 향상을 위한 보호시스템 구성 및 특성 분석)

  • Seok-Hwan Cho;Jae-Sub Ko;Dae-Kyong Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.591-599
    • /
    • 2024
  • This paper presents the configuration and characteristic analysis of the protection system to improve the safety of the building integrated photovoltaic(BIPV) system. BIPV is a solar power system installed in buildings. Since the BIPV system is installed in buildings, there is a high risk of electric shock and fire accidents. Therefore, in order to improve the safety of BIPV, a protective system is required to block or quickly detect risk factors. In this paper, as a protection system to improve the safety of the BIPV system, it is composed of a rapid shutdown (RSD) that can quickly separate the PV system to prevent fire and electric shock accidents and a system to detect Arc faults that cause PV system fires. RSD and Arc Fault Detector analyzed the operating characteristics according to each condition and confirmed that the safety of the BIPV system can be improved through this.

The Improvement of Protection against Electric Shock to Introduced International Standards(IEC 60364-4-41) (국제표준(IEC 60364-4-41) 도입에 대한 감전보호 개선연구)

  • Kim, Jun-Taek;Kim, Han-Su;Lee, Kang-Hee;Lee, Geum-Hwan;Shin, Ki-Hyun;Lee, Hyo-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1629-1630
    • /
    • 2015
  • 기술기준의 선진화 및 국제표준화가 요구됨에 따라 현행 기준과 규정 등에 국제표준(IEC)을 도입하여 적용하고 있다. 감전보호 관련 국제표준인 IEC 60364-4-41(감전에 대한 보호), IEC 60479(인체와 가축에 대한 전류의 영향), IEC 61140(감전보호), IEC 61201(규약 접촉 전압 한계의 이용)는 이미 국내에 도입되어 전기설비에 적용되고 있다. 감전보호 관련 국제표준(IEC)에서 이론적 개념과 실험데이터를 종합적으로 정리하여 설비에 적용할 수 있도록 규정을 하고 있는 표준이 IEC 60364-4-41이다. 이러한 IEC 60364-4-41은 국내표준과의 차이점 등으로 인해 현장에서 사용하는데 많은 어려움이 있다. 따라서 IEC 60364-4-41의 원활한 적용을 위해서는 이러한 문제점 및 해결책을 파악하고, 필요한 개선사항 등을 연구할 필요가 있다.

  • PDF

Improvement of Lighting Installation Technical Standard in Waterpark, Public Bath and Similar Places for the Prevention of Electric Shock (감전사고 방지를 위한 물놀이.입욕시설의 조명설비 시설기준 개선방안 연구)

  • Kim, Chong-Min;Kim, Han-Sang;Kim, Gi-Hyun;Yi, Geon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.78-85
    • /
    • 2006
  • A person's body resistance in the waterpark, public bath and similar places is much lower than any other places due to effect of water. So low voltage may create a shock hazard for the human body in case of leakage or fault currents from lighting unit etc. We researched the related regulations which are internal standards, NEC, IEC and investigated the actual conditions for the prevention of electric shock due to lighting units in the waterpark, public bath and similar places. As a results internal standard is obscure as compared with NEC, IEC which is the limit of application and distinction of environment condition. And then internal standard's using voltage is higher than NEC, IEC in filed of water. Studies show that internal standard should be revision that raise the installation height of lighting unit, mark IP level surface of lighting unit and limit using voltage to line-to-line voltage

Performance Evaluation of the Hybrid Defrost Process in the Fin-Tube Evaporators of Refrigerators (하이브리드 제상 방식을 적용한 냉장고용 핀-관 열교환기의 제상 성능 평가)

  • Lee, Su-Won;Park, Yong-Joo;Kweon, Lae-Un;Jeong, Young-Man;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.38-46
    • /
    • 2011
  • The hybrid defrost process combined with hot-gas bypass defrost and electric heater defrost was experimentally evaluated about its defrost performance in the fin-tube evaporators of household refrigerators. Also the hybrid defrost process was compared with only electric heater defrost process. The defrost efficiency of the hybrid defrost process was shown two times higher than electric heater defrost process. The defrost time of the hybrid defrost process was shorten about 10%~50% than electric heater defrost process. Thermal shock after defrost process was decreased about 50% for the case of the hybrid defrost. It was found that energy consumption ratio of defrost process was reduced up to 7.4% compared with 22.4% of electric heater defrost at the condition of $25^{\circ}C$ ambient temperature.

Behavioral Response and Immune Alterations by Electric Footshock in Mice (생쥐에서 전기자극 스트레스에 의한 행동반응과 면역 기능 변화)

  • Kim, Jung-Bum;Park, Won-Kyun;Song, Dae-Kyu
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.4 no.1
    • /
    • pp.44-53
    • /
    • 1996
  • The present experiment was designed to investigate the effects of behavioral, response to immune function in response to electric footshock in mice. Mice were subjected to electric footshock for 3 days(two sessions a day, 11 times of shock for about 31 minutes a session). The humoral immune response was measured using mice immunized with rat RBC. The cell-mediated immune responses were evaluated by contact hypersensitivity to 2, 4-dinitrofluorobenzene(DNFB) and by phytohemagglutin(PHA)-stimulated splenocytes proliferation assay. In stressed group, electric footshock suppressed significantly anti-rat RBC antibody production(p<0.05), but enhanced significantly $T_{48}$ relative to $T_{24}$ in contact hypersenstivry (P<.01) and T-cell proliferation response(P<.05) by PHA stimulation elative to control group. T-cell proliferation response by PHA stimulation was significantly correlated to the movement than the sensitivity and coping behavior in the mouse, in response to the electric footshock. These data supper the importance of behavioral response in stress-induced changes of immune functions.

  • PDF

Underground parking lot planning study for electric vehicle charging and parking (전기자동차 주차 및 충전을 위한 지하주차장 계획연구)

  • Chin, Kyung Il;Moon, Jin Woo
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.39-44
    • /
    • 2013
  • As the use of electric vehicles perspectively increases, infrastructures for charging car batteries need to be properly planned for satisfying new requirements. This study aimed at theoretically investigating the relative laws, size of existing parking lots, and diverse car sizes for suggesting parking places for electric vehicles. In addition, potential problems for changing existing parking lots to new parking lots for electric vehicles were thoroughly considered. Based on the problem recognition, the feasibility, in particular, of the change of existing parking place to new place equipped with electricity charging systems was investigated. The comprehensive reviews and surveys revealed that additional systems for charging electricity need to be developed to be suspended on the ceiling for existing parking lots in order to prevent changing current layout of the space. This system will alleviate the perspective problems when the charging systems are located on the floor such as contamination, electric shock, and damage by cars. Further study will be followed for testing performance of the suggested systems in the actual parking lots.

A Study on the Characteristics of the Clutch Automation Mechanism of Hybrid Vehicles (하이브리드 차량용 클러치 자동화 기구의 특성 연구)

  • Lim, Won-Sik;Park, Sung-Cheon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.778-783
    • /
    • 2012
  • Due to the increase of oil price, the needs of the reduction of the fuel cost is rising. Therefore, necessity of hybrid vehicle that runs with engine and the electric motor is on the rise. In order to improve the performance of hybrid vehicle, many researches is carried out. Hybrid vehicles have been developed with the various layout such as serial type, parallel type, power split type, and multi-mode type. The multi-mode hybrid vehicles are designed to show the efficient driving characteristics at low speed and high speed. But the multi-mode system have the problem such as frequent clutch engagement. Frequent clutch engagement causes the shock of vehicles, and the shock inhibits the ride comfort. In this study, automation mechanism of clutch operation is proposed to mitigate the shock at engaging clutch. For this purpose, the dynamic characteristics of motor control is numerically analyzed by using Matlab/Simulink.

A Study on the Electrical Safety Evaluations of Transformer Insulation Cover (변압기용 절연커버 재질의 전기 안전성 평가에 관한 연구)

  • Kim, Hyang-Kon;Han, Woon-Ki;Gil, Hyung-Jun;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.433-436
    • /
    • 2004
  • In this paper, we studied on the electrical safety evaluations of transformer insulation cover. In order to take preventive measures against an electric shock disaster in 22.9kV transformer installation, we put the insulation cover on a transformer charging parts. It needs to be designed so that the insulation covers have superior properties such as, arc-resistance, weather-resistance and heat-resistance, because they are used until the damage and destruction occur. To establish the protection cover to reduce the electrical shock, we analyzed damage mechanism and risk factors which happened by structural fault of an insulation cover in this paper. Also, based on the experimental results, we are planing to suggest new improved insulation cover models.

  • PDF