• Title/Summary/Keyword: Electric voltage

Search Result 4,165, Processing Time 0.033 seconds

Neutral-Point Voltage Balancing Control Scheme for Fault-Tolerant Operation of 3-Level ANPC Inverter (3-레벨 ANPC 인버터의 고장 허용 운전 시 중성점 전압 균형 제어 기법)

  • Lee, Jae-Woon;Kim, Ji-Won;Park, Byoung-Gun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.120-126
    • /
    • 2019
  • This study proposes a neutral voltage balance control scheme for stable fault-tolerant operation of an active neutral point clamped (ANPC) inverter using carrier-based pulse width modulation. The proposed scheme maintains the neutral voltage balance by reconfiguring the switching combination and modulating the reference output voltage in order to solve the degradation of the output characteristic in the fault tolerant operation due to the fault of the power semiconductor switch constituting the ANPC inverter. The feasibility of the proposed control scheme is confirmed by HIL experiment using RT-BOX.

The Electrical Characteristics of Varistor. (바리스터의 전기적 특성)

  • Hong, Kyung-Jin;Jang, Dong-Hwan;Cho, Jae-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.52-56
    • /
    • 2001
  • The Breakdown electric field of ZnO semiconductor devices in voltage-current characteristics was increased by increasing of additive materials. The specimen that has not additive materials was not formed spinel structure. The critical voltage that has not spinel structure was 235[V]. When the additive materials has 0.5 and 2[mol%], the Breakdown electric field was 840 and 758[V] in each additive materials. The Breakdown electric field of varistors as a factor of voltage and current was increased by addition of oxide antimony. The varistors that has oxide antimony was linearly increased in low electric field.

  • PDF

Analysis of Induced Voltage in Parallel Telecommunication Cables from Underground Power Cables (지중송전선로와 병행하는 기설통신선의 유도전압 분석)

  • Lim, Kwang-Sik;Chang, Woo-Seog;Han, Chang-Seok;Hong, Dong-Suk;Yoo, Jin-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.523-524
    • /
    • 2011
  • This paper covers induced voltage in parallel telecommunication cable with underground power cable to be linked between substations. The simulation was carried out the induced voltage in telecommunication cable according to the transposition of power cables and fault location for various conditions. This study based on the EMTP/ATPDraw with actual underground cable systems while the power cables are in steady state and transient state.

  • PDF

In Situ Observations of Sintering Process during Pulsed Current Sintering of $Al_2O_3$, ZnO and WC ALLOY

  • Kawakami, Yuji;Tamai, Fujio;Enjoji, Takashi;Shikatani, Noboru;Misawa, Tatsuya;Otsu, Masaaki;Takashima, Kazuki
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.810-811
    • /
    • 2006
  • Pulsed Current Sintering (PCS) process possesses some problems that need to be resolved. We, therefore aims at understanding phenomena of PCS process by presenting some basic data on in situ sintering behavior of PCS. Special graphite mold equipped with thermo couple and electrodes were designed to measure the temperature, electric current and voltage inside the powder during PCS process. We apply three types of raw materials, especially for ZnO as semiconductor, $Al_2O_3$ as non-conductor and WC as good conductor. The electric current and voltage were measured for each powder during PCS process. In addition, their electric resistance properties were calculated.

  • PDF

A Study on Development of Arc Fault Circuit Interrupter Used in House Distribution Line (옥내 배전선로용 아크차단기 개발에 관한 연구)

  • Kwak, Dong-Kurl;Choi, Jung-Kyu;Park, Young-Jic;Kim, Jin-Hwan;Son, Jae-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.546-547
    • /
    • 2013
  • This paper proposes an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. It perceives a voltage instantaneously at the time of voltage drop. and occurrence. It is an AFCI of the new concept which operates with high reliability. The primary reason of electric fire is arc and spark. It prevents an electric fire or an electric leakage accident with quick responsiveness. Earth Leakage Circuit Breaker(ELB), Molded_case Circuit Breaker (MCCB) or Residual Current Protective Device(RCD) can not cut off electric arc or spark to be a major factor of electrical fire. This theory will be able to intercept an arc or a spark. which occurrence with periodic. Consequently It raises a reliability and validates a practicality of RCD.

  • PDF

Study about varying aspects of flicker indices by load fluctuating in electric railway system (전기철도환경하에서 부하변동에 따른 플리커지수의 변화양상에 대한 연구)

  • Lee Kang-Won;Kim Myung-Yong;Baik Kwang-Sun;Kim Won-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.655-659
    • /
    • 2005
  • The environment. of electric railway has, included both fast and slow load variation, which may occur in the office or maintenance factory or running electric train. This paper investigated flicker indices according to voltage fluctuations on three different situations; The base office in new subway in the daytime and night time, inside of electric train running in conventional subway. And also the variations of harmonic frequencies(2nd, 3rd, 5th) with rime were measured at the same time. Flicker index is a good tool for evaluating the voltage fluctuation quantitatively and show some relationship with even harmonic frequencies produced by the voltage fluctuation when the electric train is running on the railway.

  • PDF

A Development of Unified Digital Generator Controller (발전기 통합제어장치 개발)

  • Yoo, Young-Suk;Kwon, Hyuk;Lee, Sang-Jeong;Lee, Sun-Hee;Choi, Yong-Sil
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1164-1166
    • /
    • 1996
  • This system is an unified Digital Generator Controller. It has an Electronical Generator Sequencer which control the sequence of a generator, an AVR(Automatic Voltage Regulator) which perform the regulation of generator terminal voltage optimally to user's needs, and an Auto Synchronizer, it can switch the power source on from generally used an the generator to load automatically. It also possesses a Battery Charger which charge a storage battery to appropriate voltage level. Here we describe it's configuration, specifications, the way of control, figure, functions and waveforms.

  • PDF

Analysis on the Method of Forward-Reverse Fault localization of Electric Railways for the Improvement of Accuracy (전기철도 정역방향 고장점표정 방법을 통한 정확도 향상을 위한 연구)

  • Kim, Myeong Su;Kim, Seong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1735-1742
    • /
    • 2018
  • The number of electric railway failures will increase due to the external and internal effects of electric railroads. The grounding test with 25,000V is to artificially test the transmission voltage to ground, and it is possible to cause risks of electric shock and other equipment insulation damage in neighboring enclosure. In 2016, method of fault localization changed to low - voltage at 380V from artificially high- voltage in the grounding tests since opening of Seoul Metropolitan Express Railway; The method is more accurate and safer rather than the previous one because it gets more data from unlimited grounding tests. However, an electric current falls on the track section where the track branches and vehicle bases with many lines. To precisely detect a transitive phenomenon, it is necessary to continuously study and additionally install.

Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation (교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발)

  • Kim, Sung-An;Han, Sung-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.

DC-Link Voltage Balance Control in Three-phase Four-wire Active Power Filters

  • Wang, Yu;Guan, Yuanpeng;Xie, Yunxiang;Liu, Xiang
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1928-1938
    • /
    • 2016
  • The three-phase four-wire shunt active power filter (APF) is an effective method to solve the harmonic problem in three-phase four-wire power systems. In addition, it has two possible topologies, a four-leg inverter and a three-leg inverter with a split-capacitor. There are some studies investigating DC-link voltage control in three-phase four-wire APFs. However, when compared to the four-leg inverter topology, maintaining the balance between the DC-link upper and lower capacitor voltages becomes a unique problem in the three-leg inverter with a split-capacitor topology, and previous studies seldom pay attention to this fact. In this paper, the influence of the balance between the two DC-link voltages on the compensation performance, and the influence of the voltage balance controller on the compensation performance, are analyzed. To achieve the balance between the two DC-link capacitor voltages, and to avoid the adverse effect the voltage balance controller has on the APF compensation performance, a new DC-link voltage balance control strategy for the three-phase four-wire split-capacitor APF is proposed. Representative simulation and experimental results are presented to verify the analysis and the proposed DC-link voltage balance control strategy.