• Title/Summary/Keyword: Electric stimulus

Search Result 70, Processing Time 0.029 seconds

Comparison of blood flow ratio between normal and diabetic neuropathy group using photoplethysmograph (PPG를 이용한 정상인과 당뇨병 환자의 혈류량 비교)

  • Lee, Ju-Hyung;Kim, Sung-Woo;Kang, Eun-Seok;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.77-79
    • /
    • 2007
  • The purpose of this study was to suggest a new detection method for early diagnosing diabetic neuropathic foot by obtaining a ratio of toe to figer blood flow using photoplethysmography(PPG). Nerve conduction velocity (NCV) has been routinely used for diagnosing neuropathic foot, but it applies strong electric stimulus to peripheries resulting in stress and pain. The blood flow ratio of diabetic neuropathy(0.96${\pm}$0.20) was significantly higher in comoarison to normal control group(0.46${\pm}$0.15, left : p<0.05, right : p<0.05) and non-neuropathy diabetic group(0.49${\pm}$0.21, left: p<0.05. right: p<0.05).

  • PDF

Analyzing the Emotional State EEG by Mutual Information (상호정보에 의한 감성상태 뇌파분석)

  • 김응수
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.4
    • /
    • pp.304-309
    • /
    • 2000
  • For understanding the information processing in human brain, we analyze the EEG, a spontaneous electric activity on the scalp of the human. In this paper, we used the mutual information to analyze EEG. The mutual information is used to show the stochastic correlation between signals which are generated in the communication and information theory. The used EEG is evoked by each auditory stimulus in positive and negative emotional states. As a result, we found thet there is some difference at the mutual information in each emotional state.

  • PDF

Preparation and Swelling Behaviors of Hydrogel Composed of Alginate, Poly(N-isopropylacrylamide) and Polyaniline

  • Lee, Young Moo;Seo, Sung Mi;Lee, Sang Bong
    • Korean Membrane Journal
    • /
    • v.6 no.1
    • /
    • pp.37-43
    • /
    • 2004
  • Comb-type graft hydrogels composed of alginate and poly(N-isopropylacrylamide) (PNIPAAm) were prepared to manifest rapid temperature and pH sensitivity. To appear the electro-sensitivity, the polyaniline, conducting polymer, was added into the matrix. The swelling kinetics and ratios were compared under the various compositions of polyaniline. The swelling behaviors revealed that conducting polymer/hydrogel composites could control the swelling ratio and kinetics. The addition of polyaniline in the matrix improved the thermal stability in comparison with that of the hydrogel without polyaniline. In temperature sensitivity, the adding the polyaniline into the matrix decreased the degree of change in the swelling ratio. The swelling ratios continuously increased with increasing pH values. The drug release rate from the hydrogel increased with the adding the polyaniline and the applying the direct voltage to the hydrogels.

The Research of the HERO Test and Evaluation Technique (HERO 시험평가 기법 연구)

  • Shin, Seung-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.76-83
    • /
    • 2007
  • This report presents the test technique using optic thermal sensor for the HERO evaluation of equipment installed EED. The calibration method of EED-thermal sensor assembly is explained by relation between the current in bridge wire and voltage in thermal sensor. And the HERO test and evaluation method is indicated based on MIL-STD-464A and MIL-STD-331C. The safety and reliability levels of EED-thermal sensor assembly are evaluated when exposed in the electromagnetic environment.

A study on the Electrical Properties by Electric Field Stimulus of Organic Thin Films (유기박막의 전계자격에 의한 전기 특성에 관한 연구)

  • 조수영;전동규;송진원;김해진;이우선;최영일;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.49-52
    • /
    • 1999
  • We studied on the ultra thin DMPC by Langmuir-Blodgett(LB) method. The $\pi$ -A isotherm of the DMPC was measured at the air-water interface varying with the compressing speed and amounts of solutions for spreading. DMPC molecules have one phosphatidylcholine head group and two long alky groups with carbonyl group. Displacement currents generated during the compression of monolayers of DMPC on the surface of water were investigated. The molecular arrangement of deposited films were evaluated by measuring the absorption with the UVspectrometer. And we made structures of metal(Au)/DMPC/Metal(Au) and examined electron through DMPC LB films by means of current-voltage(I-V) measurement .

  • PDF

A Study on Neuroactive Response Measurement Platform using Mechano Sensor (Mechano sensor를 이용한 신경자극반응 측정 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.198-201
    • /
    • 2012
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls. The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation, Train-of-four, and Double Burst Stimulation in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

Analysis of Meridians Potential Change for Meridians State Diagnosis (경락상태진단을 위한 경락의 전위변화 분석)

  • 이용흠;고수복;정석준;정동명
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.405-412
    • /
    • 2002
  • The principle of Acupuncture effect on meridians is what physical stimulation does on general physiology so that is gets into new equilibrium from the fallen function state of human body. However, in western medicine, it is generally accepted that the action passageway of various kinds stimulation has been regarded as nerve-endocrine-immune system. Acupuncture effect has been regarded any action for all meridians as a respones by the stimulation. Western medicine doesn's accept treatment for transmission of the bio-energy. In this paper, we compared change of electric potential when an acupuncturist's bio-energy is passed on and when is not. As a result of clinics, the acupuncture effect is different as acupuncture method, when an acupuncturist's bio-energy is passed on the meridian and it isn's. It implies that acupuncture effect can complicately respond by simple acupuncture stimulus and transmission of bio-energy, on same meridian. We could confirm the relationship between an acupuncturist's energy transmission and acupuncture effect. Therefore, we could diagnosis the state of meridian using change of electric potential on the same meridian.

A Study on Neuroactive Response Sensing Platform after Injection of Muscular Relaxants (근 이완제 투여에 따른 신경 자극 반응 감지 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.331-334
    • /
    • 2011
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls.The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation(STS), Train-of-four(TOF), and Double Burst Stimulation(DBS) in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

Analysis on Visual Preference of Golf Course -The case of Tae-gu Country Club- (골프장의 시각적선호분석 -대구 칸트리 클럽을 사례로-)

  • 김용수;성영탁
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.21 no.1
    • /
    • pp.13-30
    • /
    • 1993
  • The purpose of this study was to present data to the landscape planning and design through analyzing correlation between visual preference of users and nonusers and the landscape of hole in golf couses. Stimulus objects were selected from the 18 holes in Tae-gu Country Club. Preference value was judged through photo simulation by 35 subjects photographed at Tee and Interpoint (IPI, IP2), and classified into three landscape types and nine landscape components from photo analysis by researcher. For test of difference between groups toward each stimulus, t-test was used, and Duncantest, Correlation analysis for finding out correlation between preference degree and the landscape of each hole. The results of this study were as follows: As a result of analysis of preference value between groups for each hole, it has been shown that there was scarcely difference with each other. Form the relation between preference degree and spacial structure of hole, the holes making up a superior preference group have been shown that the greater part of the holes had a downward slope or a gentle slope mostly and then a visible ratio of fairway was high, and had diversified scenery by a lotus pond, a solitary planting tree, the roll of a fairway, facilities for convenience, etc. The holes making up a low-ranking preference group have been shown that the greater part of the holes had upward slope or a similar slope to it and had characteries of the bad condition of lawn, the nearby factories and odors, the monotonous scenery of a fairway, an unreasonable mixing of holes, etc. From the relation between preference degree and landscape components forming hole, it has been shown that the preference degree between users and nonusers had positive correlation to the occupied ratio of space of landscape components at Tee and Approach. At Tee, it has been shown that the preference degree of two groups were related with a lawn surface of fairway negatively, a lotus pond, a sky positively, and the preference degree of nonusers was related with iron-top for electric transmission positively. At Approach, it has been shown that the preference degree of two groups were related with iron-top for electric transmission negatively, and the preference degree of nonusers was related with a building positively. From the relation between preference degree group to each hole and the occupied ratio of space of landscape types, it has been shown that the constituent ratio of a high-ranking group was 1:2.4:2.2 and a low-ranking group was 1:4.1:5.1 among vertical type, horizontal type and background at Tee, but the constituent ratio of space of a high-ranking group was similar to a low-ranking group at Approach.

  • PDF

Evaluation of the change of lower lip sensation after inferior alveolar nerve block by using the electric pulp tester (하치조신경 마취 후 전기치수검사기(Electric pulp tester)를 이용한 하순부 감각 변화 평가)

  • Ku, Myong-Suk;Kim, Jin-Wook;Jeon, Young-Hoon;Kwon, Tae-Geon;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.6
    • /
    • pp.464-469
    • /
    • 2011
  • Introduction: As dental implant surgery is becoming increasingly popular, it has become one of the causes for the hypesthesia of the inferior alveolar nerve, along with other surgical procedures, such as a third molar extraction. In addition, it tends to cause legal problems between the operator and patient. Therefore, there must be a proper method that is reliable, objective and economical to assess the nerve impairment. For this reason, an attempt was made to use an Electric Pulp Tester to assess inferior alveolar nerve block anesthesia. Materials and Methods: Thirty patients were tested. Electric pulp testing of the lower jaw skin was performed at the three different times, before anesthesia, at the onset of sensory changes and after 15 minutes waiting from the onset, and on the 10 points of the chin, which produced 10 sections on the skin area. Results: Twenty seven patients (90%) could feel the electric stimulus on the chin at all 10 points before local anesthesia and the scores represent the statistical differences between the right and left points except R4 and L4. After anesthesia, the difference between the right and left points (L3-R3, L4-R4, L5-R5) increased significantly with time but two points (L2, R2) showed no significant difference. The scores on the left chin (L3, L4, L5) increased, whereas the other points (R1-R5, L1, L2) showed no significant differences. Conclusion: This study highlights the potential clinical use of an electric pulp tester for an assessment of inferior alveolar nerve impairment.