DOI QR코드

DOI QR Code

Evaluation of the change of lower lip sensation after inferior alveolar nerve block by using the electric pulp tester

하치조신경 마취 후 전기치수검사기(Electric pulp tester)를 이용한 하순부 감각 변화 평가

  • Ku, Myong-Suk (Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyungpook National University) ;
  • Kim, Jin-Wook (Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyungpook National University) ;
  • Jeon, Young-Hoon (Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyungpook National University) ;
  • Kwon, Tae-Geon (Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyungpook National University) ;
  • Lee, Sang-Han (Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyungpook National University)
  • 구명숙 (경북대학교 치의학전문대학원 구강악안면외과학교실) ;
  • 김진욱 (경북대학교 치의학전문대학원 구강악안면외과학교실) ;
  • 전영훈 (경북대학교 치의학전문대학원 구강악안면외과학교실) ;
  • 권대근 (경북대학교 치의학전문대학원 구강악안면외과학교실) ;
  • 이상한 (경북대학교 치의학전문대학원 구강악안면외과학교실)
  • Received : 2011.07.24
  • Accepted : 2011.10.12
  • Published : 2011.12.31

Abstract

Introduction: As dental implant surgery is becoming increasingly popular, it has become one of the causes for the hypesthesia of the inferior alveolar nerve, along with other surgical procedures, such as a third molar extraction. In addition, it tends to cause legal problems between the operator and patient. Therefore, there must be a proper method that is reliable, objective and economical to assess the nerve impairment. For this reason, an attempt was made to use an Electric Pulp Tester to assess inferior alveolar nerve block anesthesia. Materials and Methods: Thirty patients were tested. Electric pulp testing of the lower jaw skin was performed at the three different times, before anesthesia, at the onset of sensory changes and after 15 minutes waiting from the onset, and on the 10 points of the chin, which produced 10 sections on the skin area. Results: Twenty seven patients (90%) could feel the electric stimulus on the chin at all 10 points before local anesthesia and the scores represent the statistical differences between the right and left points except R4 and L4. After anesthesia, the difference between the right and left points (L3-R3, L4-R4, L5-R5) increased significantly with time but two points (L2, R2) showed no significant difference. The scores on the left chin (L3, L4, L5) increased, whereas the other points (R1-R5, L1, L2) showed no significant differences. Conclusion: This study highlights the potential clinical use of an electric pulp tester for an assessment of inferior alveolar nerve impairment.

Keywords

References

  1. Noma H, Sasaki K. Disturbance and regeneration of the inferior alveolar nerves. 1st ed. Tokyo: Ishiyaku Publishing; 2001.
  2. Certosimo AJ, Archer RD. A clinical evaluation of the electric pulp tester as an indicator of local anesthesia. Oper Dent 1996;21:25-30.
  3. Yikontiola L, Kinnunen J, Oikarinen K. Comparison of different tests assessing neurosensory disturbances after bilateral sagittal split osteotomy. Int J Oral Maxillofac Surg 1998;27:417-21. https://doi.org/10.1016/S0901-5027(98)80028-3
  4. Korean Dental Society of Anesthesiology. Dental Anesthesiology. 1st ed. Seoul: Koonja Publishing; 2005.
  5. Ghali GE, Epker BN. Clinical neurosensory testing: practical applications. J Oral Maxillofac Surg 1989;47:1074-8. https://doi.org/10.1016/0278-2391(89)90184-5
  6. Ghali GE, Jones DL, Wolford LM. Somatosensory evoked potential assessment of the inferior alveolar nerve following third molar extraction. Int J Oral Maxillofac Surg 1990;19:18-21. https://doi.org/10.1016/S0901-5027(05)80562-4
  7. Jaaskelainen SK, Teerijoki-Oksa T, Forssell H. Neurophysiologic and quantitative sensory testing in the diagnosis of trigeminal neuropathy and neuropathic pain. Pain 2005;117:349-57. https://doi.org/10.1016/j.pain.2005.06.028
  8. Kim YW, Kim MR. Diagnostic efficacy of DITI (Digital Infrared Thermographic Imaging) for the dysesthesia of the lower lip & chin. J Korean Assoc Oral Maxillofac Surg 2002;28:53-60.
  9. Lerner TH, Goldstein GR, Hittelman E. Quantitative sensory nerve conduction threshold (sNCT) evaluation of the trigeminal nerve at the mental foramen area. J Prosthet Dent 2000;84:103-7 https://doi.org/10.1067/mpr.2000.107336
  10. Kim JS, Nam KC, Kim SC, Lee SJ, Kim DW. Development of an electric pulp tester with constant current source. IEEK 2004; 41:123-30.
  11. Dal Santo FB, Throckmorton GS, Ellis E 3rd. Reproducibility of data from a hand-held digital pulp tester used on teeth and oral soft tissue. Oral Surg Oral Med Oral Pathol 1992;73:103-8. https://doi.org/10.1016/0030-4220(92)90164-L
  12. Walline BW, Wagner JG, Marx DB, Reinhardt RA. Comparison of methods for measuring root and mucogingival sensitivity. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000;90:641-6. https://doi.org/10.1067/moe.2000.109659
  13. McDaniel KF, Rowe NH, Charbeneau GT. Tissue response to an electric pulp tester. J Prosthet Dent 1973;29:84-7. https://doi.org/10.1016/0022-3913(73)90144-3
  14. Mikesell A, Reader A, Beck M, Meyers W. Analgesic efficacy of volumes of lidocaine in human maxillary infiltration. J Endod 1987;13:128. https://doi.org/10.1016/S0099-2399(87)80180-2
  15. Vreeland DL, Reader A, Back M, Meyers W, Weaver J. An evaluation of volumes and concentrations of lidocaine in human inferior alveolar nerve block. J Endod 1989;15:6-12. https://doi.org/10.1016/S0099-2399(89)80091-3
  16. Nam KC, Ahn SH, Kim SC, Kim DW, Lee SJ. Measurement of the excessive stimulus time after the sensory threshold level during electric pulp testing. J Korean Acad Cons Dent 2004;29:226-32. https://doi.org/10.5395/JKACD.2004.29.3.226