• 제목/요약/키워드: Electric field interference

검색결과 104건 처리시간 0.021초

Electromagnetic interference caused by an electric-line current in a cable tray in nuclear power plants

  • Lee, Hoon-Keun;Kim, Yong-Hwa;Choo, Jaeyul
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3314-3318
    • /
    • 2021
  • This paper presents a mode-matching analysis of the electromagnetic coupling between open cable trays in an indoor structure when an electric-line current is generated as an electromagnetic source. We validated the mode-matching method by comparing the mode-matching results with those computed from a commercial electromagnetic simulator and then investigated the strength of the electric-field coupled in a victim cable tray while varying the distances between cable trays and architectural surfaces. The results of this study provide geometrical information on the placement of open cable trays to avoid electromagnetic interference problems.

Surface-Plasmon Assisted Transmission Through an Ultrasmall Nanohole of ~ 10 nm with a Bull's Eye Groove

  • Kim, Geon Woo;Ko, Jae-Hyeon;Park, Doo Jae;Choi, Seong Soo;Kim, Hyuntae;Choi, Soo Bong
    • Journal of the Korean Physical Society
    • /
    • 제73권11호
    • /
    • pp.1698-1702
    • /
    • 2018
  • We simulate the light transmission through an extremely small nanoscale aperture having a 10 nm diameter punctured in a metal film positioned at the center of a plasmonic bull's eye grating. A considerable directive emission of transmitted light with a divergence angle of 5.7 degrees was observed at $10{\mu}m$ from the nanohole opening at the frequency of surface plasmon polariton excitation, an confirmed by measuring the distance dependent transmission amplitude. Observations of the electric field in cross-sectional, near-field, and far-field views near-field enhancement associated with the surface plasmon excitation, and the interference of the electric field light through the nanohole in the near-field region is responsible for such a considerable directive emission.

3차원 유한요소법을 이용한 TFT-LCD 액정에서의 공간 전기장 분포 특성 분석 (Characteristic Analysis of Spacial Electric Field Distribution in Liquid Crystal of TFT-LCD Panel)

  • 정상식;김남경;김동훈;노민호;이규상
    • 한국자기학회지
    • /
    • 제22권3호
    • /
    • pp.91-96
    • /
    • 2012
  • 복잡한 전극 구조를 갖는 TFT-LCD 패널의 픽셀 사이의 간섭효과를 고려하여 액정에서의 공간 전기장 분포를 정밀하게 예측할 수 있는 멀티 픽셀 기반의 3차원 유한요소 수치해석 모델을 구축하였다. 이를 토대로 패널 내 다양한 전극 불량 조건에 대한 액정에서의 공간 전기장 분포 특성을 정상 상태와 비교 분석 하였다. 이러한 수치모사 결과와 기존 광학적 패널 검사장비의 불량검출 결과를 간접 비교함으로써 제안한 3차원 유한요소 수치모델의 타당성을 검증하였다.

전력선을 이용한 광케이블 현장 실증 시험 (A field trial of helically wrapping fiber optic cable onto existing 154KV Phase conductor.)

  • 신건학;이원빈;조홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.143-146
    • /
    • 1987
  • Fiber optics provide a solution to the problems at interference, capacity and reliability in communication. Approximately 20 kilometera of a six-fiber, multimode, longwave($1.3{\mu}m$), graded index silica glass fiber optic cable was helically wrapped around a phase conductor at a Korea Electric Power Corporation(KEPCO) 154KV transmission line. This paper presents an economic comparison of several fiber optic cable installation alternative and discusses the characteristics at the helically wrapped fiber cable, as well as the entire installation, including high voltage phase-to-ground (PTG) end termination, and splicing. The fiber link was installed for the field trial and practical use with overhead composite optical fiber cable which installation performed a few years earlier some other location and is intended to accommodate not only telephone but also supervisory Control and Data Acquisition(SCADA), protective relaying, and telemetry functions.

  • PDF

매설배관과 직류전기철도의 표유전류 간섭분석 (Analysis of Stray Current Interference between Underground Pipelines and DC Electric Railways)

  • 하윤철;배정효;하태현;이현구;김대경
    • 한국가스학회지
    • /
    • 제10권3호
    • /
    • pp.41-47
    • /
    • 2006
  • 가스배관, 상수관, 송유관 등의 지중 매설배관이 직류 전기철도와 인접해 있는 경우, 전기철도 시스템의 귀선 회로로 사용되는 레일에서 누설되는 표유전류에 의해 이들 금속배관에는 전기적 부식, 즉 전식이 발생할 수 있다. 전식에 의한 집중 부식은 전기방식으로 보호되는 배관에 있어서도 지속적인 재료의 열화와 이에 따른 파손을 일으킬 수 있어 대형사고로 발전할 소지를 가지고 있다. 국내에서는 이러한 표유전류에 대한 대책으로 배관과 레일을 전기적으로 접속하는 배류법이 적용되고 있는데 특히 가스배관을 중심으로 한 강제배류법의 급속한 증가에 의해 간섭문제가 매우 복잡해지고 있다. 본 논문에서는 직류전기철도시스템과 매설배관 사이의 전기적 간섭 문제를 서울과 부산 지역에서 수행한 현장 실태조사의 결과를 통해 살펴본다.

  • PDF

Measurement of Transient Electric Field Emission from a 245 kV Gas Insulated Substation Model during Switching

  • Rao, M. Mohana;Thomas, M. Joy;Singh, B.P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.306-311
    • /
    • 2007
  • The transient fields generated during switching operations in a Gas Insulated Substation (GIS) are associated with high frequency components in the order of few tens of MHz. These transient fields leak into the external environment of the gas-insulated equipment and can interfere with the nearby electronics. Measurements of the transient fields are thus required to characterise the interference caused by switching phenomena in such substations. In view of the above, E-field emission measurement during a switching operation has been carried out for a 245 kV GIS model, using a resonant dipole antenna and D-dot sensor. The characteristics of the E-fields i.e., frequency spectra and their levels have been analysed and are reported in the paper. Suitability of the measurements has been confirmed by comparing frequency spectra of the measured and computed transient fields.

A Shared Channel Design for the Power and Signal Transfers of Electric-field Coupled Power Transfer Systems

  • Su, Yu-Gang;Zhou, Wei;Hu, Aiguo Patrick;Tang, Chun-Sen;Hua, Rong
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.805-814
    • /
    • 2016
  • Electric-field coupled power transfer (ECPT) systems have been proposed as an alternative wireless power transfer (WPT) technology in recent years. With the use of capacitive plates as a coupling structure, ECPT systems have many advantages such as design flexibility, reduced volume of the coupling structure and metal penetration ability. In addition, wireless communications are effective solutions to improve the safety and controllability of ECPT systems. This paper proposes a power and signal shared channel for electric-field coupled power transfer systems. The shared channel includes two similar electrical circuits with a band pass filter and a signal detection resistor in each. This is designed based on the traditional current-fed push-pull topology. An analysis of the mutual interference between the power and signal transmission, the channel power and signal attenuations, and the dynamic characteristic of the signal channel are conducted to determine the values for the electrical components of the proposed shared channel. Experimental results show that the designed channel can transfer over 100W of output power and data with a data rate from 300bps to 120 kbps.

상용화 드론을 이용한 송전선로 점검방안 및 현장시험 (Patrol Monitoring Plan for Transmission Towers with a Commercial Drone and its Field Tests)

  • 김석태;박준영;이재경;함지완;최민희
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.115-123
    • /
    • 2018
  • 과거 송전선로를 점검하기 위하여 선로를 주행하는 로봇시스템을 이용하여 점검방법이 있었으나 선로를 주행하기 위한 구동장치와 장애물을 회피하기 위한 복잡한 메커니즘 등으로 시스템 자체가 무거워 선로에 설치하기가 어렵고 선로의 장애물을 완벽하게 회피하여 주행하지 못하는 단점이 있었다. 그래서 공중에서 비행하며 점검하는 비행로봇 형태가 개발됐고 최근 회전익 멀티콥터 형태 드론의 비행안정도가 높아짐에 따라 전력산업에도 전력설비 점검에 이용되기 시작했다. 배전설비를 수동조종으로 비행하는 드론을 이용하여 점검해 왔다. 그러나 송전선로나 철탑의 경우, 설비 규모가 크고 경간 거리가 멀어 비행 중인 드론의 위치와 송전선로간의 거리를 가늠하기 어렵기 때문에 드론을 수동으로 시계비행하며 송전선로를 점검하기에는 선로와의 충돌위험에서 자유롭기 어렵다. 또한, 수동조종으로 선정된 웨이포인트(Way-point)에 의존한 자동비행점검도 송전선로에 형성되는 자기장에 의해 드론의 전자식 나침판이 오작동하여 비행방향의 오류를 초래하므로 송전선로와의 충돌 가능성이 여전히 상존한다. 그러므로 본 논문에서는 송전선로의 자기장을 영향에 대한 드론점검 작업환경을 조사하고 이를 근거로 자기장 영향권 밖에서 비행경로를 생성하여 고배율카메라와 열화상 카메라가 탑재된 상용화 드론을 이용하여 자동비행하면서 송전선로를 점검할 수 있는 체계를 소개한다. 또한, 이 점검체계를 이용하여 충남지역의 154 kV, 345 kV, 765 kV 등 전압별 실 선로에 대하여 적용한 현장시험결과를 소개하고자 한다.

765kV 송전선로용 특수 다중도체 방식의 코로나 잡음특성 및 전계분포 해석 (Analysis on Electric Field Distributions and Corona Characteristics of Special Conductor Bundles for 765kV Transmission Line)

  • 민석원;김용준;신구용;이동일;주문노;양광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.556-560
    • /
    • 2001
  • To solve aeolian noise, we have tried several special conductor bundles equipped with spiral rod and one kind of low aeolian noise conductor with a special shape. Charge simulation method was applied to analyze electric field distributions of them in transmission line and corona cage for investigating the corona characteristics. This paper describes the electric field distributions and the performances of audible noise and radio interference from the special bundles in 765 kV transmission line by using corona characteristics obtained from corona cage simulation.

  • PDF

765kV 2회선 송전선의 코로나 방전에 의한 환경영향 연구 (Environmental effects by corona discharge from a 765kV double circuit transmission line)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.451-455
    • /
    • 1996
  • This paper specified the measurement results conducted by the Korea Electric Power Research Institute (KEPRI) 765kV double circuit transmission test line that measured the audible noise, hum noise, radio interference, electric field and aeolian measurement. This test line consists of 6-480mm$^{2}$ conductors per phase. The analysis of the test results shows that this 6-Rail conductor bundle satisfies the audible noise criterion under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion. (author). 9 refs., 7 figs., 2 tabs.

  • PDF