• Title/Summary/Keyword: Electric apparatus

검색결과 321건 처리시간 0.021초

고온 태양열 공기식 흡수기의 충진재 변화에 따른 열전달 및 압력강하 성능 분석 (Honeycomb and Laminated Mesh as Open Volumetric Solar Receiver : Performance of Heat Transfer and Pressure Drop)

  • 조자현;이주한;강경문;서태범
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.760-766
    • /
    • 2008
  • The characteristics of heat transfer and pressure drop of several different porous materials which can be used as inserts inside solar volumetric air receivers were experimentally investigated. Generally, porous materials were inserted into solar volumetric air receivers to increase the thermal performance. In the present work, honeycomb (diameter: 100 mm, thickness: 30 mm), laminated mesh (diameter: 100 mm, thickness: 1 mm) are considered as the inserts for the experiment. The experimental apparatus consists mainly of a cylindrical ceramic duct as a receiver and an electric heater as an energy source. This system is an intake open loop, which used as air of working fluid. The temperatures inside the ceramic tube are measured by thermocouples, which are installed at each layer of the porous materials. The pressure-drop experimental apparatus is fabricated alike the above experimental equipment. An acrylic tube is used like as the ceramic tube, which has the same specifications of the ceramic tube. The pressure drop of porous materials inserted in the acrylic tube is measured between front and rear of those by transmitter. The results show that the laminated mesh surpasses the honeycomb of heat transfer and pressure drop increase as the porous material thickness and Reynolds number.

저항을 이용한 프로판-공기 혼합가스의 점화한계 개선에 관한 연구 (A Study on the Improved Ignition Limit with Resistor for Propan-air Mixture Gas)

  • 이춘하;오종용;옥경재;지승욱;이광식;심광렬
    • 한국화재소방학회논문지
    • /
    • 제18권1호
    • /
    • pp.18-23
    • /
    • 2004
  • 본 논문은 IEC형 불꽃점화 시험장치를 이용하여 저압 유도회로의 최소 점화한계를 프로판-공기 5.25 Vol.%의 혼합 가스에 대하여 실험적으로 구하였으며, 또한 유도회로의 인덕턴스 L에 안전소자로서 저항을 병렬접속 하였을 경우 프로판-공기 5.25 Vol.%의 혼합 가스에 대한 점화한계 개선효과를 고찰하였다. 그 결과, 최소 점화한계는 전류의 크기에 따라 좌우되었다. 또한, 전원으로부터 공급되는 에너지는 인덕턴스에 우선 축적되고, 그 초과분의 에너지가 폭발성 가스의 점화원으로 작용하였다. 점화한계 개선효과는 인덕턴스가 300mH일 때, 최고 330%의 개선효과가 나타났으며 인덕턴스가 클수록 점화한계 개선효과가 크게 나타났다. 또한 병렬로 접속한 저항의 크기가 적을수록 점화한계 개선 효과가 크다. 본 연구결과는 본질안전 방폭형 전기기기의 연구개발을 위한 기본자료로 활용할 수 있을 뿐만 아니라 이들 기기의 방폭 성능에 대한 시험자료로도 활용이 가능할 것으로 사료된다.

국산재의 응용물성연구II: 잣나무 낙엽송의 수분흡착성 및 열적·전기적·음향적 성질 (Study on Physical Properties of Domestic Species II: Sorption, Thermal, Electrical and Acoustic Properties of Pinus koraiensis and Larix kaempferi)

  • 변희섭;이원희;박병수;정성호;강호양
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권4호
    • /
    • pp.1-10
    • /
    • 2008
  • 주요 국산재의 여러 가지 응용물성을 매년 3수종씩, 3년에 걸쳐 조사하였다. 전보에 이어 우리나라의 침엽수 대표 수종인 잣나무 및 낙엽송을 사용하였다. 매년 동일한 장치와 실험조건으로 실험하였기 때문에 모든 수종에 대한 결과를 상호 비교할 수 있었다. 수분흡착성 실험은 목분을 이용하였으며, 넓은 범위의 상대습도조건에 따른 평형함수율과 흡착등온선을 구하였다. 열전도율과 열확산률은 열선열전도장치를, 전기의 부피저항률과 저항은 고전기저항계를 이용하여 측정하였다. 정목재와 판목재의 열적 전기적 특성차이가 관찰되었는데 이는 해부학적 차이에 의한 것으로 보인다. 음향적 성질은 음향측정시스템을 사용하여 동적탄성률, 내부마찰을 측정하였다. 본 논문의 결과들은 목재구조물 설계, 휴대용 목재수분계 보정, 음향적 성질 등에 필요한 기본 자료를 제공한다.

촉매적(觸媒的) 제탄(製炭)에 관(關)한 시험(試驗) (Studies on the catalytic charcoaling)

  • 박태식;박명규
    • 한국산림과학회지
    • /
    • 제3권1호
    • /
    • pp.18-22
    • /
    • 1963
  • 1. Objects The experiments of catalytic aharcoaling were carried out for the fallowing purposes. (1) To determine the economically desirable amount of catalytic materials to be used when a catalytic charcoaling is practiced. (2) To observe the rate of carbonization of non-treated charcoal wood when the catalytic charcoaling is proceeded in the same charcoal pit. 2. Meterials (1) Small sample chips made of oak (Q. accutissima Carr.), measured by 0.5cm in width and thickness, respectively, and 1cm in length, were used as charcoal wood in each experiment. (2) Ammonium chloride was used as a catalytic material and electric kiln as a charcoaling apparatus. 3. Experiment (1) The sample chips were put into a electric oven for three hours at the temperature $60^{\circ}{\sim}70^{\circ}C$ in order to reduce some water contents. (2) Oven dried sample chips were then soaked for an hour in solution of ammonium chloride. Three kinds of solution were prepared, that is, 2.5%, 5%, and 10%, solution in which the amount of ammonium chloride used was weighed at the rate of 0.5%, 1.0%, and 2.0% to the total weight of the sample chips, resppectivelly. (3) Soaked sample chips were put in the air for 12 hours to reduce some water contents, and then were put into electric oven for 2 hours at the temperature $105^{\circ}{\sim}110^{\circ}C$. (4) Dried sample chips were kept in a desiccator with control sample chips which were treated excarly the same process as the treated sample chips except only not using the ammonium chloride in the process of soking. (5) Sample chips kept in the desiccator were used at random in each charcoaling experiment. (6) Charcoaling in the electric kiln were carried out by using small crucibles with complete cover to reduce the amount of ash. At each charcoaling experiment four crucibles filled with sample ships, weighed about 20gr, were put into electric kiln. The charcoaling was continued for an hour at the temperature $400^{\circ}{\sim}450^{\circ}C$. (7) In order to investigate the influence given by the gases produced during the catalytic charcoaling to the rate of carbonization of non-treated sample chips, the following experiment was done. (a) A crueible was divided into two parts by inserting a fine iron net at the middle of the crucible, and then non-treated sample chips, weighed about 10gr, were put in the upper part of the crucible and treated sample chips, weighed also about 10gr, were put in the under part. (b) The crucibles filled with two kinds of sample chips were put into a electric kiln for an hour at the temperature $400^{\circ}{\sim}450^{\circ}C$. 4. Results. Results for two replications (with four crucibles in one replication) for each experiment designed are as follows : (1) The rats of carbonization of the non treated sample chips, and that of the treated sample chips with ammonium chloride at the rate of 1.5%, 1.0%, and 2.0% to the total weight of the sample chips used were averaged at 19.85%, 22.63%, 24.14%, and 26.60%, respectively. (2) The rats of carbonization of the non-treated sample chips were averaged at (a) 20.04% (0.5% treatment), (b) 20.28% (1.0% treatment), and (c) 20.61% (2.0% treatment) when the treated sample chips were carbonized in the same crucible.

  • PDF

국내 평가 가이드 라인 제시를 위한 전동식 부항기의 특성 조사에 관한 연구 (Study of Mechanical Characteristics of Electric Cupping Apparatus in Korea for Suggestion of its Assessment Guideline)

  • 이승호;김은정;신경훈;남동우;강중원;이승덕;이혜정;이재동;김갑성
    • Journal of Acupuncture Research
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : The mechanical properties of Korean electric cupping systems are studied via experimental measurements. The study aimed at establishing the fundamentals of industrialization and systemization of oriental medicine device industry, as well as improving the quality of life for many Koreans. Methods : We reviewed the studies on traditional cupping as well as modern one to fine necessary factors for electric cupping systems. To characterize the mechanical properties of Korean electric cupping systems, we measured the pressure characteristics of commercially available electric cupping system by using an automatic pressure acquisition system and a standard cup. The pumping capability was checked at 40 seconds, and the stability of the suction cup was checked at 600 seconds. We also acquired the noise level of each system in clinical setting. To check the portability of each system, we also measured its physical dimensions. We scrutinized system manuals provided by the system manufacturers. Results : It took less than 5 second to reach the pressure if the connection between the air hose and the vacuum valve of the cupping system was secure. Pressure diminished to no more than 10% for 600s for all systems. Noise levels were 55~70 dB. Increase in pressure was too fast to control for a designated vacuum level except for one product. Conclusions : The Pumping ability of the systems is impressive and reliable. Pressure retention ability of each cup is quite reliable and reproducible. Therefore, their mechanical performances were worthy of recommendation. Some of them had noise level higher than 60 dB and they were bothersome. It was also suggested that the control for low to middle pressure needed to be accomplished by the cupping system.

국산재의 응용물성연구 I: 소나무(Pinus densiflora)의 수분흡착성 및 열적·전기적·음향적 성질 (Study on Physical Properties of Domestic Species I: Sorption, Thermal, Electrical and Acoustic Properties of Pinus Densiflora)

  • 강호양;변희섭;이원희;박병수;박정환
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권3호
    • /
    • pp.70-84
    • /
    • 2008
  • 국산재의 여러 가지 응용물성을 매년 3수종씩, 3년에 걸쳐 조사하였다. 첫 수종으로 우리나라의 대표 수종인 소나무를 사용하였다. 매년 동일한 장치와 실험조건으로 실험하였기 때문에 모든 수종에 대한 결과를 상호 비교할 수 있다. 수분흡착성 실험은 목분을 이용하였으며, 가열처리조건에 따른 평형함수율과 흡착등온곡선을 구하였다. 열전도율과 열확산률은 열선열전도장치를, 전기의 부피저항률과 저항은 고전기저항계를 이용하여 측정하였다. 정목재와 판목재의 열적 전기적 특성차이가 관찰되었는데 이는 해부학적 차이에 의한 것으로 보인다. 음향측정시스템을 사용하여 동적탄성률, 내부마찰을 측정하였다. 본 논문의 결과들은 목재구조물 설계, 휴대용 목재수분계 보정, 비파괴검사 등에 필요한 기본 자료를 제공한다.

빛의 직진 개념 지도를 위한 탐구 학습모듈의 개발 및 적용 (Development and Application of Inquiry Modules for Instruction for the Concept of Straight propagation of Light)

  • 김규환;김중복
    • 과학교육연구지
    • /
    • 제35권2호
    • /
    • pp.173-192
    • /
    • 2011
  • 이 연구는 빛의 직진에 관한 교사들의 개념이 어떠한지 살펴보고, 나타난 여러 대안개념들을 개선하기 위해 필요한 적절한 학습모듈의 개발에 주목한 것으로서 올바른 빛의 직진 개념 형성을 위한 실험장치와 work sheet의 고안 및 활용의 효과성을 살펴보고 이에 따른 교육적 시사점을 얻고자 이루어졌다. 개발된 실험장치와 work sheet는 현직 교사들로 하여금 올바른 과학 개념을 가질 수 있도록 하는지 알기 위해 초 중등학교 교사 75명(초등 8명, 중등 67명)을 대상으로 적용수업이 이루어졌고 적용수업 전 후에 교사들의 개념을 알아보기 위하여 사전검사와 사후검사가 각각 이루어졌다. 결과의 분석은 사전검사 및 사후검사 무응답 등의 이유로 중등교사 5명을 제외한 70명의 교사들에 대하여 이루어졌다. 실험장치를 이용한 적용수업 전, 대다수의 교사들이 가진 대안 개념으로 실험장치의 바닥판에 빛이 비쳐 밝게 보이는 모양 자체를 빛의 진행경로로 생각하는 것으로 드러났으나 실험장치를 이용한 적용수업 이후 바닥판에 빛이 비친 모양을 빛의 진행경로로 생각하는 유형의 수가 크게 감소하였다. 아울러 수업 전, 빛의 진행경로의 출발점을 잘못 그린 것과는 반대로 거의 모든 교사가 광원인 전구로부터 시작하여 빛의 진행경로를 그리는 올바른 개념으로 변화하였다.

  • PDF

다중공 평판형 장비를 이용한 감압법과 열자극법에 의한 하이드레이트 가스 생산성 분석 (Hydrate Production Performance Analysis with Multi-Well, Plate-Type Apparatus Using Depressurization and Thermal Methods)

  • 이영수;왕지훈;박정균;성원모
    • Korean Chemical Engineering Research
    • /
    • 제47권1호
    • /
    • pp.133-140
    • /
    • 2009
  • 본 연구에서는 투과도 80 md, 하이드레이트 포화도 30%의 다중공 평판형 시스템에서 열자극 감압법에 의한 생산실험을 수행하여 하이드레이트의 해리양상 및 생산효율을 관측 및 분석하였다. 감압의 크기에 따른 실험결과에서, 운영 압력을 낮게 설정하면 높은 가스회수율을 얻을 수 있지만 생산초기 나타나는 강한 펄스가 생산전 운영에 무리를 줄 수 있다고 판단되었다. 또한 흡열반응에 의한 하이드레이트 재형성으로 오히려 회수율이 감소하는 경우가 발생하였다. 감압법 적용시의 생산거동을 더 상세히 분석하기 위해, 감압크기 140 psi와 320 psi에 대해 각각 4, 6회의 반복실험을 진행하였다. 그 결과, 140 psi로 감압크기를 설정한 경우, 생산초기에 불안정한 거동이 나타나지만, 빠르게 안정화됨을 알 수 있었다. 320 psi의 실험결과에서 불연속적이며 간헐적인 생산거동을 확인할 수 있었다. 열자극 실험은 안정적인 생산거동을 보이며 회수율이 비교적 낮아 열자극의 효과를 잘 관찰할 수 있는 압력차 80 psi를 적정운영 압력으로 설정하여 수행하였다. 열자극감압 혼용기법의 결과로부터 열자극시간이 증가할수록 가스회수율은 증가하였지만, 반면 에너지효율은 오히려 감소하는 것으로 나타났다. 열을 2분간 가한 후 열흡수 시간을 1분으로 설정한 경우 본 시스템에서는 회수율이 상승하였으며, 에너지효율 또한 증가되는 결과를 얻었다. 하지만, 열흡수 시간이 1분 이상일 경우 오히려 더 낮은 회수율과 에너지효율을 보였는데 이는 긴 열흡수 시간으로 인한 열손실에 기인한 것으로 판단된다.

Charged membrane에 의한 negative electric field가 토끼 장골의 골 치유에 미치는 영향 (The Effect of Negative electric field using charged PTFE membrane on Bone Healing of Rabbit Long Bone)

  • 권용수;박진우;이재목;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제34권3호
    • /
    • pp.551-562
    • /
    • 2004
  • 골재생을 위한 술식은 자가골, 합성골 등의 이식술, 골견인술, 골유도 재생술 등이 있으며, 더 나은 결과를 위해서 성장 인자나 cytokine의 적용, 전기적 자극 등이 이용될 수 있다. 이 중 골재생을 위한 전기적 자극을 이용한 골재생 방법에서 비교적 양호한 결과가 보고되어지고 있으며, 전기적 자극은 크게 direct current, inductive coupling, capacitive coupling으로 나뉘어 사용, 연구되어지고 있다. 하지만, 위의 전기적 자극들은 비교적 침습적이고, 환자들에게 불편감을 줄 수 있으며, 부가적인 장치가 필요한 단점이 있다. 따라서, 본 실험에서는 골재생을 촉진하기 위한 비침습적인 전기자극의 방법으로, negatively charged membrane을 이용하여, 토끼 요골의 골절성 결손부에서 negative electric field가 골재생에 미치는 영향을 연구하고자 하였다. 8마리 토끼의 양 요골에 10mm의 골절성 결손부를 형성한 후, 코로나 방전 장치로 -l000V로 대전시킨 polytetrafluoroethylene membrane을 사용하여, 실험군에는 negatively charged membrane을, 대조군에는 noncharged membrane을 적용시킨 후, 2, 4, 6, 8주째 2마리씩 희생하여 조직학적, 조직형태학적 분석을 실시하였다. 2주째, 대조군에서 골결손부에 대한 신생골의 비율은 0.32%, 실험군에서는 1.10%로 나타났으며, 4주째 대조군에서 골결손부에 대한 신생골의 비율은 6.86%, 실험군에서는 13.75%로, 대조군에 비해 실험군에서 더 많은 양의 신생골이 관찰되었다. 6주와 8주째도 대조군에 비해 실험군에서 더 많은 신생골이 관찰되었으나, 그 차이는 크지 않았다. 결론적으로, 토끼 요골의 골절성 결손부의 골치유에서 negatively charged membrane을 이용한 전기적 자극은 초기 골치유를 촉진시키며, 따라서, 이러한 방법의 전기극은 장골의 치유에 있어 비침습적이며, 유용한 수단이라고 사료된다.

태양광 폐 모듈의 처리현황 및 실용화 기술 (Current Status and Utilization Technology of End-of-Life Photovoltaic Modules)

  • 조재영;박아름;윤현목;전연수;김준수
    • 자원리싸이클링
    • /
    • 제29권4호
    • /
    • pp.15-30
    • /
    • 2020
  • 최근에 태양광 발전 시설이 급격히 증가됨에 따라 사용 후 태양광 모듈의 발생량이 급증할 것으로 예상된다. 태양광 폐 모듈의 리싸이클링은 일부 국가에서 시도하고 있지만, 경제성이 확보된 실용화 기술의 부재로 폐 모듈이 방치 및 폐기되어, 환경오염은 물론 유가자원 회수 측면에서도 많은 문제를 야기시키고 있으므로 대책 마련이 시급하다. 이와 같은 현실에 비추어 본 기술개발에서는 폐 모듈의 성능검사, 알루미늄 프레임 해체, 강화유리의 파분쇄 및 박리, back sheet 및 EVA의 분리 제거, 유가금속의 침출과 침전 회수 및 폐액 처리의 기반 기술을 확립한 다음, 이를 기초로 대단위 처리 시설을 설계 제작 및 운전함으로써 실용화기술을 확립하였다. 본 연구에서는 대단위 시험을 통하여 1 ton/day 규모의 폐 모듈 처리의 최적 조건을 확립한 다음, 얻어진 자료를 근거로 경제성 검토를 실시하였다. 프레임 해체 및 강화유리 박리 공정까지는 경제성이 있었으나, 유가금속 회수를 포함한 전체 공정을 포함하면 생산자 책임(EPR) 제도의 시행에 따른 재활용 분담금의 지원이 이루어지지 않는 한 경제성이 박약하였다. 향후 태양광 폐 모듈의 수거, 재사용 인증기준, 철거비 부담, 효율적인 처리 기술 확보, 관련 법규제정 및 EPR 제도 등의 문제가 해결된다면, 경제성 확보가 용이하여 상용화가 가능할 것이다.