• Title/Summary/Keyword: Electric Panel

Search Result 303, Processing Time 0.025 seconds

High vacuum packaging and vacuum evaluation for field emission display

  • Jung, S.J.;Woo, K.J.;Lee, N.Y.;Ahn, S.;Moon, G.J.;Kim, K.S.;Kim, M.S.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.1
    • /
    • pp.95-97
    • /
    • 1999
  • A 3.12" FED panel was packaged successfully using the anode plate on which phosphors and black matrix were coated and cathode plate containing emitter arrays. The vacuum level of the panel was investigated during panel evacuation, tip-off and getter activation process. The packaged panel exhibited vacuum level below 2${\times}$10-6 Torr. Similar experiments were carried out for 10" panel made of bare plates. In addition, the vacuum level of two panels was compared continuously after tip off process; one with the getter and the other without it.

  • PDF

Dynamic Analysis of the PDLC-based Electro-Optic Modulator for Fault Identification of TFT-LCD (박막 트랜지스터 기판 검사를 위한 PDLC 응용 전기-광학 변환기의 동특성 분석)

  • 정광석;정대화;방규용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.92-102
    • /
    • 2003
  • To detect electrical faults of a TFT (Thin Film Transistor) panel for the LCD (Liquid Crystal Display), techniques of converting electric field to an image are used One of them is the PDLC (polymer-dispersed liquid crystal) modulator which changes light transmittance under electric field. The advantage of PDLC modulator in the electric field detection is that it can be used without physically contacting the TFT panel surface. Specific pattern signals are applied to the data and gate electrodes of the panel to charge the pixel electrodes and the image sensor detects the change of transmittance of PDLC positioned in proximity distance above the pixel electrodes. The image represents the status of electric field reflected on the PDLC so that the characteristic of the PDLC itself plays an important role to accurately quantify the defects of TFT panel. In this paper, the image of the PDLC modulator caused by the change of electric field of the pixel electrodes on the TFT panel is acquired and how the characteristics of PDLC reflect the change of electric field to the image is analyzed. When the holding time of PDLC is short, better contrast of electric field image can be obtained by changing the instance of applying the driving voltage to the PDLC.

Experimental Study of a Seismic Reinforcing System without Power Interruption and Movement for Electric Panel on the Access Floor (무정전-무이설 방식의 전기판넬 내진보강시스템 시험연구)

  • Jang, Jung-Bum;Lee, Jong-Rim;Hwang, Kyeong-Min;Ham, Kyung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The seismic reinforcing system is developed to prevent damage to electric panels which are installed on the access floor and are essential to the operation of various basic facilities such as electric power and communication etc., from earthquakes. The seismic capacity of seismic reinforcing system is verified through the shaking table test. The seismic reinforcing system is intended for the electric panel on the access floor, and installation is possible without movement and power interruption of the electric panel. The enveloped response spectrum is adopted considering the location of the electric panel in the building as input motion for the shaking table test. The shaking table tests are carried out with two electric panels that can be considered representative of general electric panels, and two types of access floors such as wood panel and steel panel, which are commonly used in the industrial field. As a result of tests, it is confirmed that the seismic reinforcing system secures the seismic safety of electric panels by preventing the overturning of electric panels during and after the shaking table tests. In the event that the seismic reinforcing system is applied to the electric panel on the access floor, damage to the electric panel from an earthquake can be effectively prevented, which can greatly contribute to the stable operation of domestic basic facilities.

Electric Current Accelerated Degradation Test Design for OLED TV (OLED TV Panel의 전류가속열화시험 설계)

  • You, Ji-Sun;Lee, Duek-Jung;Oh, Chang-Suk;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Purpose: The purpose of this study is to estimate the life time of OLED TV panel through electric current ADT(Accelerated Degradation Test). Methods: We performed accelerated degradation test for OLED TV Panel at the room temperature to avoid high temperature impact on the luminance. Results: we got more accurately the life time of the OLED TV when we applied ADT without temperature factor than including both current and temperature. Conclusion: Until now, the ADT of the OLED TV has been conducted with temperature and current at the same time for reducing test time and costs. We estimate incorrect life time when the temperature is adopted as an accelerated factor. Due to the high temperature impact on the luminance of the OLED TV panel. So as to solve this problem, we discard temperature and use electric current only.

Characteristics of a Home Panel Board with Surge Protection Device (서-지차단장치 내장형 단위세대 분전반의 특성)

  • 이종혁;송재용;이종호;홍경민;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.480-483
    • /
    • 2000
  • We developed a home electric panel board with surge protection device to protect home electric appliances from transient overvoltages and electromagnetic(EM) noise. In this paper, electrical characteristics of the home electric panel board are described. From the performance test using a combination surge generator standardized in IEC 610004-5, it is confirmed that the proposed home panel board has an excellent surge protection performance. Also, EM noise reduction characteristics of the panel board in ranges from 150 kHz to 30 MHz is estimated by using a network analyser, and the results showed that the panel board has an over 20 45 noise reduction performance.

  • PDF

A Novel Air-Bridge Type Gate-Data Line Inter-Crossing to Reduce Signal Delay for Large Size AMLCD (대면적 AMLCD의 신호 지연 감소를 위해 Air-gap을 갖는 게이트-데이터 라인 교차 구조)

  • Park, Jin-Woo;Kang, Ji-Hoon;Lee, Min-Cheol;Han, Min-Koo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.768-772
    • /
    • 1999
  • A new TFT-LCD panel with air-bridge type gate to data line inter-crossing has been proposed and its characteristics have been measured. The proposed structure has air-gap between gate and data line inter-crossing. This air-bridge TFT-LCD panel has very small capacitance between gate and data line. The new panes structure achieves 9 times fast signal propagation compared with conventional panel, which enables to have enough design margin for 20-inch diagonal and larger size UXGA panel. We have examined thermal and mechanical durability of new panel to verify applicability for commercial AMLCD production. After TEOS and polyimide passivation, this panel withstood a thermal stress at $250^{\circ}C$ and a mechanical stress during the rubbing process.

  • PDF

A Development of Intelligent Metering and Control System for Energy Management of Electric Cabinet Panel (분전반 전력관리용 지능형 계측 제어 시스템 개발)

  • Park, Byung-Chul;Park, Jae-Sung;Song, Sung-Kun;Shin, Joong-Rin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.90-97
    • /
    • 2013
  • In recent years, the many electric saving methods are studied because of difficulty of meeting the demand. The electric energy management such as monitoring of branch power consumption, demand control, metering, power quality monitoring, electric safety monitoring can make energy saving. The purpose of this paper is to develop a system which can provide the integrated management of various functions required for energy management by consumers. In this system all functions which were embodied into each devices are integrated into intelligent meter. The developed systems are tested and implemented by installing at consumer electric distribution panel.

Fabrication of CNT Electron Source for Field Emission Displays

  • Nakata, S.;Sawada, T.;Fujikawa, M.;Nishimura, K.;Abe, F.;Hosono, A.;Watanabe, S.;Yamamuro, T.;Shen, Z.;Suzuki, Y.;Okuda, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1012-1015
    • /
    • 2005
  • We have developed the technique of fabricating triode structure with simple stacking method using a polymer insulator that is suitable for large panel and the activation method after the fabrication. By the techniques, a test panel was manufactured and proves good emission property and uniformity.

  • PDF

Development of the Ubiquitous-based Intelligent Digital Switchgear Panel for Home Automation (유비쿼터스 기반의 주택 자동화용 디지털 분전반 개발)

  • Ko, Yun-Seok;Kim, Ho-Yong;Yun, Seok-Yeul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.741-747
    • /
    • 2008
  • This paper proposes a new concept of IDSP(Intelligent Digital Switchgear Panel) which can solve the problem of the safety, the reliability and the convenience to correspond to the requirement of the general electric customer or electric power company under the ubiquitous-based home automation environments. By analyzing their requirement functions, a 32-bit micro processor is adopted as main controller to support the designed functions efficiently. The DSP-based single phase power management device is utilized to collect the electric power information and the ethernet convertor to communicate through internet among the IDSPs and the remote computer system. In the proposed IDSP, the several functions are implemented such as the earth leakage level display and waveform transmission, the electric fee display, the voltage management, the load management and the load control function. Finally, the prototype of the IDSP is made experimently based on the designed results, and then the effectiveness is verified by testing its basic functions.

Laser Diagnostic in a Plasma Display Panel Discharge Cell

  • Choi, Young-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.21-22
    • /
    • 2000
  • Laser diagnostic method in a plasma display discharge cell was introduced. The information of electric field, potential and electron temperature et al. in the surface of plasma display panel can be measured using laser induced fluorescence spectroscopy. However, because of the very small discharge dimension of ${\sim}$ 100 ${\mu}m$, the measurement attempt has almost not been performed. In this paper, the direct measurement possibility of the parameters and the recent work of electric field measurement are demonstrated in the plasma display panel.

  • PDF