Buoy-launched Terminal Equipment and Ship-launched Gateway Equipment Based on LoRa for Identification of Fishing Gear (LoRa 기반 어구 식별용 부이 장착 단말 및 어선용 게이트웨이)

  • Kwak, Jae-Min;Lee, Seong-Real
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.5
    • /
    • pp.779-786
    • /
    • 2018
  • Ministry of oceans and Fisheries declared action plan for the electric fishing gear using real name in order to prevent overusing the fishing gear and to reduce discarded fishing gear. It is needed for a technique that can efficiently transmit the information including the type and location of the fishing gear and the user's real name to the fishing boat and the control center using IoT-based communication. In this paper, we propose the buoy-launched terminal equipment and ship-launched gateway equipment based on LoRa technology for effectively executing the electric fishing gear using real name. We design and fabricate to communicate 1(gateway):200(buoy) each other under 900 MHz ISM band by using SEMTECH SX1276 chip. Also, we experiment the test on the sea and analyze the test results to prove the implementation possibility of the proposed equipments for the electric fishing gear using real name.

A Study on the Analysis of Efficiency for Underground Distribution Equipment by Installment Ways (지중배전공사에 설치되는 기기의 설치위치에 따른 영향 분석에 관한 연구)

  • Kim, Joon-Eel;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.83-89
    • /
    • 2009
  • The environment of electrical power industry is now faced on problems such as electric rates, an increasing sensitivity in society with environmental issues and energy factors. Up to now, reliability is greatly influenced by maintenance and environmental factors that are unique to the electric utilities. The reliability is a characteristic assigned to the electric power systems's function which is related to the concept of installment of equipment. Therefore this reports's key finding is that it is important that the utilities track their individual components' value over investment expense of their installed components. This can be accomplished to consider the cases of foreign electric power companies and take into account the various possible installment ways of equipment in Korea. These results are expected to be used as a reference material for design underground distribution facilities and future applications.

Multi-Service Optical Transmission Equipment with LAN Interface for Electrical Power System (전력용 LAN 지원 다기능 광 전송장치 개발)

  • Kim, Jae-Sung;Min, Nam-Ki;Lee, Sung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1901-1902
    • /
    • 2006
  • In recent years, it has been a worldwide trend that many power utilities gave their attention to develop and operate their power plants, substation and distribution systems. Following this trend, KEPCO(Korea Electric Power Corporation) has developed many electric automation systems with various communication networks. It has been natural that the automation systems are just focused on to remote devices when they come to be designed. But, we have to shift the focus to the automation system itself. We have developed the Multi-service Optical Transmission System (M-OTS) for electrical power systems. It can be adopt to not only distribution power field but also the transmission power field. The result strongly shows that the system is potentially beneficial in reliability, speed, and expandability. This paper presents some of initial design efforts and results toward a KEPCO's communication system in distribution areas.

  • PDF

Analysis on the Method of Forward-Reverse Fault localization of Electric Railways for the Improvement of Accuracy (전기철도 정역방향 고장점표정 방법을 통한 정확도 향상을 위한 연구)

  • Kim, Myeong Su;Kim, Seong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1735-1742
    • /
    • 2018
  • The number of electric railway failures will increase due to the external and internal effects of electric railroads. The grounding test with 25,000V is to artificially test the transmission voltage to ground, and it is possible to cause risks of electric shock and other equipment insulation damage in neighboring enclosure. In 2016, method of fault localization changed to low - voltage at 380V from artificially high- voltage in the grounding tests since opening of Seoul Metropolitan Express Railway; The method is more accurate and safer rather than the previous one because it gets more data from unlimited grounding tests. However, an electric current falls on the track section where the track branches and vehicle bases with many lines. To precisely detect a transitive phenomenon, it is necessary to continuously study and additionally install.

An Analysis of Electric Noise of Railway Electric Inspection Car Measurement Module (종합검측차 검측모듈의 차상노이즈 분석)

  • Park, Young;Kwon, Sam-Young;Cho, Chul-Jin;Chae, Won Kyu;Lee, Jae-Hyeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.812-816
    • /
    • 2015
  • Recently, various monitoring systems have been proposed to detect interaction performance between trains and infrastructure, as well as, various techniques to improve the accuracy and performance of such inspection equipment in high speeds. Especially, it is important to predict electric noise of high speed trains due to its effect on detection system accuracy. In this paper, we analyze various types of electrical noise in electric vehicles to improve the accuracy of the detection module of the inspection car. In detail, analysis of electric noise of high speed railway is performed as a function of speed based on field tests that were carried out by HEMU-430X (Highspeed Eletric Multiple Unit - 430 km/h eXperiment).

Recommended Practice for Demand Factor/Diversity Factor with respect to Power Consumption Characteristics in Commercial Buildings (업무용 빌딩의 전력소비 특성을 고려한 수용률/부등률의 적용에 관한 연구)

  • 김세동
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.74-79
    • /
    • 2002
  • This paper shows a reasonable design standard factor in commercial buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, load characteristic, etc., for 23 commercial buildings. With a rapid growth of national economics with the development of intelligence society , electrical energy consumption markedly increased Expecially, it is increased electrical energy consumption in the commercial buildings and thus an energy conservation through efficient use of electricity became more important In our country, the estimation of demand factor and electric equipment capacity are not properly and thus the application of these factors are confusing and different in each electric design of the field.

Fault Diagnosis Method based on Feature Residual Values for Industrial Rotor Machines

  • Kim, Donghwan;Kim, Younhwan;Jung, Joon-Ha;Sohn, Seokman
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.89-99
    • /
    • 2018
  • Downtime and malfunction of industrial rotor machines represents a crucial cost burden and productivity loss. Fault diagnosis of this equipment has recently been carried out to detect their fault(s) and cause(s) by using fault classification methods. However, these methods are of limited use in detecting rotor faults because of their hypersensitivity to unexpected and different equipment conditions individually. These limitations tend to affect the accuracy of fault classification since fault-related features calculated from vibration signal are moved to other regions or changed. To improve the limited diagnosis accuracy of existing methods, we propose a new approach for fault diagnosis of rotor machines based on the model generated by supervised learning. Our work is based on feature residual values from vibration signals as fault indices. Our diagnostic model is a robust and flexible process that, once learned from historical data only one time, allows it to apply to different target systems without optimization of algorithms. The performance of the proposed method was evaluated by comparing its results with conventional methods for fault diagnosis of rotor machines. The experimental results show that the proposed method can be used to achieve better fault diagnosis, even when applied to systems with different normal-state signals, scales, and structures, without tuning or the use of a complementary algorithm. The effectiveness of the method was assessed by simulation using various rotor machine models.

A Study on Installation of Monitoring System of Wireless Power Transmission System (무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구)

  • Song, Young-Sang;Han, Woon-Ki;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.47-53
    • /
    • 2015
  • The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.

Development of Vertical Separated Tubular Steel Pole (종방향 분할형 관형지지물 개발)

  • Lee, Won-kyo;Mun, Sung-Duk;Shin, Kooyong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.257-262
    • /
    • 2019
  • Lattice steel towers for overhead transmission lines have been replaced by tubular steel poles due to the visual impact of large and complex shape of truss type. Demand for tubular steel poles consisting of a single frame member continues to grow because of its advantages such as visual minimization, architectural appeal and minimal site consumptions. However, there are some constraints on the transportation and construction. As the diameter of tower base has been enlarged, it may exceed minimum height limit required to pass the tunnel in case of land transportation. Also, in a narrow place where it is not easy to secure the installation areas such as mountainous places, there might be some areas wherein it must secure a wide working space so that large vehicles and working cranes will be allowed to enter. In this paper, we presented a vertical separated tubular steel pole, which is a new type of support that can be implemented for general purpose such as mountainous areas or narrow areas to improve the issues raised by breaking away from the conventional design and fabrication methods. Technical approaches for overcoming the limit of the cross-sectional size is to separate and modularize the cross-section of the tubular steel pole designed with a size that cannot be carried or assembled, and to lighten it with a weight capable of being transported and assembled in a narrow space or mountainous area. As a result of this research, it will be possible to enter small and medium sized vehicles in locations where it is restricted to transport by large-sized vehicles. In the case of mountainous areas, it will be possible to divide it into a weight capable of being carried by a helicopter and it will be easy to adjust and fabricate it with individual modules. Furthermore, in order to break away from the traditional construction method, we proposed the equipment that can be applied to the assembly of Tubular Steel Pole without using a large crane in locations where there is no accessible road or in locations wherein large cranes cannot enter. In particular, this paper shows the movable assembling equipment and some methods that are specialized for vertical separated tubular steel pole consisting of members with reduced weight. The proposed assembly equipment is a device for assembling the body of the Tubular Steel Poles. It will be installed inside the support and the modules can be lifted by using the support itself.

A Neuro Fuzzy Controller Using Auto-tuning Width of Membership Function for Equipment Systems (설비시스템을 위한 소속함수 폭의 자동동조를 사용한 뉴로퍼지 제어기)

  • 이수흠;방근태
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.2
    • /
    • pp.102-109
    • /
    • 1997
  • The width of fuzzy membership function and control rule has an effect on performance of the fuzzy controller for electric equipment systems. In this paper, the neuro-fuzzy controller is proposed to im¬prove the performance of fuzzy controller. It has the width of membership function, that is adapted to the electrical parameter using multi-layer neural network, it is applied to first order electric power system with dead time and various plant constant. The related simulation resolts show that the pro¬posed neuro fuzzy controller are superior characteristics of improved performance

  • PDF