• 제목/요약/키워드: Elastic Recoil

검색결과 27건 처리시간 0.023초

스텐트와 풍선의 상호작용을 고려한 스텐트 팽창의 유한요소해석 (Finite Element Analysis of Stent Expansion Considering Stent-Balloon Interaction)

  • 오병기;조해용
    • 대한기계학회논문집A
    • /
    • 제29권1호
    • /
    • pp.156-162
    • /
    • 2005
  • Stouts are frequently used throughout the human body, but the most critical areas are in coronary arteries. They open pathways in vessels and supply blood directly to the heart muscle. To simulate behavior of expansion for the coronary stent by balloon, the commercial finite element code LS-DYNA and ANSYS were used in the analysis. The explicit method is used to analyze the expansion of the stent and the implicit method is performed to simulate the springback that developed in a stent after the balloon pressure has been removed. Finally the experimental results for the expansion of the PS153 stents were compared with the FEM results. The springback was measured with the stents subjected to no external pressure to which stents are subjected in vivo. The simulated results were in good agreement with experimental results. Standard mechanical characteristics such as stress, plastic strains, and springback can be derived from the numerical results. These data can be used to determine maximum expansion diameter without fracture and expansion pressure considering elastic recoil.

관상동맥질환의 방사성동위원소 치료 (Brachytherapy in Coronary Artery Disease)

  • 송호천
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권2호
    • /
    • pp.113-119
    • /
    • 2006
  • Coronary artery disease is a loading cause of morbidity and mortality across the world. Percutaneous coronary intervention has become the major technique of revascularization. However, restenosis remains a major limitation of this procedure. Recently the need for repeat intervention due to restenosis, the most vexing long-term failure of percutaneous coronary intervention, has been significantly reduced owing to the introduction of two major advances, intracoronary brachytherapy and the drug-eluting stents. Intracoronary brachytherapy has been employed in recent years to prevent restenosis lesions with effective results, principally in in-stent restenosis. Restenosis is generally considered as au excessive form of normal wound healing divided up in precesses: elastic recoil, neointimal hyperplasia, and negative vascular remodeling. Restenosis has previously been regarded as a proliferative process in which neointimal thickening, mediated by a cascade of inflammatory mediators and other factors, is the key factor. Ionizing radiation has been shown to decrease the proliferative response to injury in animal models of restenosis. Subsequently, several randomized, double blind trials have demonstrated that intracoronary brachytherapy can reduce the rates of both angiographic restenosis and clinical event rates in patients undergoing percutaneous coronary intervention for in stent restenosis. Some problems, such as late thrombosis and edge restenosis, have been identified as limiting factors of this technique. Brachytherapy is a promising method of preventing and treating coronary artery restenosis.

THE EFFECT OF THE HIGH DENSITY PLASMA ON THE DIAMOND-LIKE CARBON FILMS

  • Kim, H.;D.H. Jung;Park, B.;K. C. Yoo;Lee, J. J.;J. H. Joo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 추계학술발표회초록집
    • /
    • pp.54-54
    • /
    • 2003
  • DLC films were deposited on Si(100) substrates by inductively coupled plasma (ICP) assisted chemical vapor deposition (CVD). A mixture of acetylene (C$_2$H$_2$) and argon (Ar) gases was used as the precursor and plasma source, respectively. The structure of the films was characterized by the Raman spectroscopy. Results from the Raman spectroscopy analysis indicated that the property change of the DLC films is due to the sp$^3$ and sp$^2$ ratio in the films under various conditions such as ICP power, working pressure and RF substrate bias. The hydrogen content in the DLC films was determined by an electron recoil detector (ERB). The roughness of the films was measured by atomic force microscope (Am). A microhardness tester was used for the hardness and elastic modulus measurement. The DLC film showed a maximum hardness of 37㎬. In this work, the relationship between deposition parameters and mechanical properties were discussed.

  • PDF

Ion-cut에 의한 SOI웨이퍼 제조에서의 양성자조사기구 (Proton implantation mechanism involved in the fabrication of SOI wafer by ion-cut process)

  • 우형주;최한우;김준곤;지영용
    • 한국진공학회지
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2004
  • 양성자 주입과 웨이퍼접합기술을 접목한 ion-cut기술로서 SOI 웨이퍼를 제조하는 기술을 개발하고자 하였다. TRIM 전산모사결과 표준 SOI 웨이퍼 (200 nm SOI, 400 nm BOX) 제조를 위해서는 65 keV의 양성자주입이 요구됨을 알 수 있었다. 웨이퍼분리를 위한 최적 공정조건을 얻기 위해 조사선량과 열처리조건(온도 및 시간)에 따른 표면변화를 조사하였다. 실험결과 유효선량범위는 6∼$9\times10^{16}$ $H^{+}/\textrm{cm}^2$이며, 최적 아닐링조건은 $550^{\circ}C$에서 30분 정도로 나타났다. 주입된 수소의 깊이분포는 ERD(Elastic Recoil Detection)와 SIMS(Secondary Ion Mass Spectrometry)측정에 의해 실험적으로 확인되었다. 아울러 상해층의 미세구조 형성기구를 X-TEM측정을 통해 조사하였다.

ECR-PECVD 방법으로 증착된 a-C:H 박막의 수소함량 측정 (Measurement of hydrogen content in a-C:H films prepared by ECR-PECVD)

  • 손영호;정우철;정재인;김인수;배인호
    • 한국진공학회지
    • /
    • 제10권1호
    • /
    • pp.119-126
    • /
    • 2001
  • ECR-PECVD 방법으로 ECR 플라즈마 소스 power, $CH_4/H_2$ 가스 혼합비와 유량, 증착시간 및 기판 bias 전압을 변화시켜 가면서 수소가 함유된 비정질 탄소 박막을 증착하고, 증착조건에 따라서 박막 내부에 함유되어 있는 수소함량 변화를 2.5 MeV 헬륨 이온빔을 사용하는 ERDa로 측정하였다. ERDA의 결과와 hES 및 RBS에 의한 성분분석으로부터 본 실첨에서 증착된 박막은 탄소와 수소만으로 구성 되어있음을 확인할 수 있었고, FTIR의 결과로부터 박막 증착조건에 따라서 박막 내부에 함유되어 있는 수소함량이 변화함을 알 수 있었다. 기판 bias 전압을 증가시킬수록 이온충돌 현상이 두드러져 탄소와 결합하고 있던 수소원자들이 떨어져 나가는 탈수소화 현상으로 수소함량이 크게 감소됨을 알 수 있었다. 그 밖의 조건에서는 박막증착 초기에는 수소보다 탄소량이 좀 더 많다가 점차적으로 수소함량이 증가되었고, 이때 박막 내부에 함유되어 있는 수소함량은 45~55% 범위 내에 있음을 확인할 수 있었다.

  • PDF

Growth and Characterization of Conducting ZnO Thin Films by Atomic Layer Deposition

  • Min, Yo-Sep;An, Cheng-Jin;Kim, Seong-Keun;Song, Jae-Won;Hwang, Cheol-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권9호
    • /
    • pp.2503-2508
    • /
    • 2010
  • ZnO thin films were grown on Si or $SiO_2$/Si substrates, at growth temperatures ranging from 150 to $400^{\circ}C$, by atomic layer deposition (ALD) using diethylzinc and water. Despite the large band gap of 3.3 eV, the ALD ZnO films show high n-type conductivity, i.e. low resistivity in the order of $10^{-3}\;{\Omega}cm$. In order to understand the high conductivity of ALD ZnO films, the films were characterized with X-ray diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, elastic recoil detection, Rutherford backscattering, Photoluminescence, and Raman spectroscopy. In addition, the various analytical data of the ZnO films were compared with those of ZnO single crystal. According to our analytical data, metallic zinc plays an important role for the high conductivity in ALD ZnO films. Therefore when the metallic zinc was additionally oxidized with ozone by a modified ALD sequence, the resistivity of ZnO films could be adjusted in a range of $3.8{\times}10^{-3}\;{\sim}\;19.0\;{\Omega}cm$ depending on the exposure time of ozone.

고에너지 중이온 TOF-ERDA를 이용한 박막분석

  • 홍완;우형주;김영석;김기동;김준곤;최한우
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.77-77
    • /
    • 1999
  • 박막시료의 분석에는 RBS, XPS, SIMS, AES 등이 주로 이용되고 있으며, 특히 RBS는 비교체가 필요없고 정량성이 좋다는 장점 때문에 중요하다. 그러나 RBS는 원리적으로 경원소에 대한 감도가 낮아 기판원소보다 무거운 질량을 갖는 원소의 분석에만 이용되는 것이 보통이다. 이러한 단점을 보완하기 위해 본 연구에서는 수년전부터 RBS와 비슷한 원리를 갖고 같은 장비를 이용하여 수행이 가능한 경원소 분석법인 TOF-ERDA(Time of Flight Elastic Recoil detection)을 개발하여 실용화 하였다. 본 연구실에서 보유하고 있는 미국 NEC사의 5SDH 가속기는 최대 가속전압이 1.7MV로 Cl5+ 이온을 사용하는 경우 10 MeV가 최대 가속에너지가 된다. 이런 정도의 에너지 범위에서는 TOF spectrometer의 시간분해능이 아주 높을 필요가 없고 비교적 작은 가속기로도 분석이 가능하며, 수소의 검출효율이 우수하다는 점 등 많은 장점이 있다. 그러나 한편으로는 분석가능한 깊이가 수천 $\AA$ 정도로 제한되고 질량 분해능도 수십 MeV 내지 100MeV 이상의 고에너지 이온빔을 이용하는 경우에 비해 떨어진다는 단점이 있다. 또한 묵운 원소의 분석이 불가능하기 때문에 경원소의 분석에 국한하여 적용하고 무거운 원소에 대해서는 RBS를 병용하게 된다. 본 연구에서는 일본 이화학연구소의 선형가속기인 RILAC으로부터 얻은 40MeV Ar 이온 및 138 MeV Xe 이온을 이용하여 TOF-ERDA 시스템을 제작하였다. 그러기 위해서 고에너지 이온의 비행시간을 측정하는 목적으로 높은 시간 분해능을 갖는 시간 검출기를 설계, 제작하였다. 또한 표적함 밑에는 회전원판이 있어 시간검출기 및 에너지 검출기가 중앙의 시료홀더를 중심으로 회전이 가능하도록 되었다. 회전은 표적함 밖에서 원격조정 가능하다. 이렇게 함으로써 검출각을 임의로 바꾸면서 측정이 가능하도록 하였다. 제작된 분석시스템의 성능을 확인하기 위해 YBaCuO 초전도 박막을 측정하였으며 그 결과를 그림에 나타낸다. 저 에너지 ERDA에서는 나타나기 힘든 Ba, Y, Cu 등의 무거운 원소의 피크들이 분명히 나타남을 확인할 수 있다.

  • PDF

반사방지 특성을 통일시킨 실리콘 질화막 간의 패시베이션 특성 비교 (Comparison of Passivation Property on Hydrogenated Silicon Nitrides whose Antireflection Properties are Identical)

  • 김재은;이경동;강윤묵;이해석;김동환
    • 한국재료학회지
    • /
    • 제26권1호
    • /
    • pp.47-53
    • /
    • 2016
  • Silicon nitride ($SiN_x:H$) films made by plasma enhanced chemical vapor deposition (PECVD) are generally used as antireflection layers and passivation layers on solar cells. In this study, we investigated the properties of silicon nitride ($SiN_x:H$) films made by PECVD. The passivation properties of $SiN_x:H$ are focused on by making the antireflection properties identical. To make equivalent optical properties of silicon nitride films, the refractive index and thickness of the films are fixed at 2.0 and 90 nm, respectively. This limit makes it easier to evaluate silicon nitride film as a passivation layer in realistic application situations. Next, the effects of the mixture ratio of the process gases with silane ($SiH_4$) and ammonia ($NH_3$) on the passivation qualities of silicon nitride film are evaluated. The absorption coefficient of each film was evaluated by spectrometric ellipsometry, the minority carrier lifetimes were evaluated by quasi-steady-state photo-conductance (QSSPC) measurement. The optical properties were obtained using a UV-visible spectrophotometer. The interface properties were determined by capacitance-voltage (C-V) measurement and the film components were identified by Fourier transform infrared spectroscopy (FT-IR) and Rutherford backscattering spectroscopy detection (RBS) - elastic recoil detection (ERD). In hydrogen passivation, gas ratios of 1:1 and 1:3 show the best surface passivation property among the samples.

전자회전공명 플라즈마를 이용한 a-C:H 박막의 특성 연구 (The Study on Characteristics of a-C:H Films Deposited by ECR Plasma)

  • 김인수;장익훈;손영호
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 2001년도 춘계학술대회논문집:21세기 신지식정보의 창출
    • /
    • pp.224-231
    • /
    • 2001
  • 2.45 GHz 마이크로웨이브를 사용하는 전자회전공명 플라즈마를 이용하여 화학적 기상증착(electron cyclotron resonance plasma enhanced chemical vapor deposition; ECR-PECVD) 방법으로 ECR 마이크로웨이브 power, CH$_4$/H$_2$가스 혼합비와 유량, 증착시간, 그리고 기판 bias 전압 등을 변화시켜 가면서 수소가 함유된 비정질 탄소(a-C:H) 박막을 증착하였고, 증착시킨 박막의 특성을 AES(Auger electron spectroscopy), ERDA(elastic recoil detection analysis), FTIR(Fourier transform infrared) 및 Raman 측정 등으로 조사하였다. 증착시킨 a-C:H 박막은 탄소 및 수소원소들로만 구성되어 있음을 AES 측정으로 확인하였다. 그리고 FTIR 측정으로부터 a-C:H 박막은 대부분 sp$^3$결합을 하고 있고 일부는 sp$^2$결합을 하고 있음을 확인하였으며, CH$_4$/H$_2$가스 혼합비와 유량의 변화가 a-C:H 박막의 탄소와 수소의 결합구조에 큰 영향을 미치지 않았으며, 다만 증착시간이 증가할수록 탄소와 수소 원자들의 결합구조가 $CH_3$구조에서 CH$_2$나 CH 구조로 변하고 있음을 알았다. 또한 Raman 스펙트럼의 Gaussian curve fitting을 통하여 sp$^3$/sp$^2$의 결합수에 비례하는 D 및 G peak의 면적 강도비(I$_{D}$/l$_{G}$)는 기판 bias 전압을 증가시킬수록 증가하였으며, 경도도 역시 증가하였다.하였다.

  • PDF

Betamethasone이 일측폐장절제 가토폐장의 압력-용적곡선에 미치는 영향 (Effect of Betamethasone on the Pulmonary Pressure-Volume Curve in Unilateral Pneumonectomized Rabbits)

  • 이영만;이석강
    • The Korean Journal of Physiology
    • /
    • 제17권1호
    • /
    • pp.23-28
    • /
    • 1983
  • steroid가 폐절제에 의한 대상성증식기의 폐장의 압력-용적곡선에 어떤 영양을 미칠 것인가를 알아보기 위해 실시한 본 실험의 결과를 요약하면 폐절제군은 대조군에 비해 폐용압률이 증가하였고 폐절제후 반대측폐장의 무게는 대조군에 비해 폐절제군이 유의하게 증가하였고 폐절제후 betamethasone을 투여한 군에 있어서는 대조군에 비해서는 증가하였으나 폐절제군보다는 적게 증가하였다. 또한 이러한 결과들은 betamethasone에 의해 폐포표면활성물질의 분비가 증가하였거나 혹은 betamethasone이 폐장실질의 결합조직의 단백대사에 영향을 미쳐 elastic recoil force가 감소하여 생긴 결과라고 생각된다.

  • PDF