References
- Arjomand H, Turi ZG, McCormick D, Goldberg S. Percutaneous coronary intervention: historical perspectives, current status, and future directions. Am Heart J 2003;146:787-96 https://doi.org/10.1016/S0002-8703(03)00153-4
- Giedd KN, Bergmann SR. Myocardial perfusion imaging following percutaneous coronary intervention: theimportance of restenosis, disease progression, and directed reintervention.J Am Coll Cardiol 2004;43:328-36 https://doi.org/10.1016/j.jacc.2003.09.032
- Kaluza GL, Raizner AE. Brachytherapy for restenosis after stenting for coronary artery disease: itsrole in the drug-eluting stent era. Curr Opin Cardiol 2004;19:601-7 https://doi.org/10.1097/01.hco.0000142069.39957.03
- Beyar R. Novel approaches to reduce restenosis. Ann N Y Acad Sci 2004;1015:367-78 https://doi.org/10.1196/annals.1302.032
- Haude M, Erbel R, Issa H, Meyer J. Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents. J Am Coll Cardiol 1993;2126-34
- Garratt KN, Holmes DR, Bell MR, Bresnahan JF, Kaufmann UP, Vlietstra RF, et al. Restenosis after directional coronary atherectomy: differences between primary atheromatous and restenosis lesions and influences of subintimal tissue resection. J Am Coll Cardiol 1990;16:1665-71 https://doi.org/10.1016/0735-1097(90)90317-I
- Mintz GS, Kent KM, Pichard AD, Popma JJ, Satler LF, Leon MB. Intravascular ultrasound insights into mechanisms of stenosis formation andrestenosis. Cardiol Clin 1997;15:17-29 https://doi.org/10.1016/S0733-8651(05)70315-5
- Schwartz RS, Murphy JG, Edwards WD, Camrud AR, Vlietstra RE, Holmes DR. Restenosis after balloon angioplasty: a practical proliferative model in porcine coronary aterries. Circulation 1990;82:2190-200 https://doi.org/10.1161/01.CIR.82.6.2190
- Hojo Y, Ikeda U, Katsuki T, Mizuno O, Fukazawa H, Kurosaki K, et al. Interleukin 6 expression in coronary circulation after coronary angioplasty as a risk factor for restenosis. Heart 2000;84:83-7 https://doi.org/10.1136/heart.84.1.83
- Rubin P, Williams JP, Riggs PN, Bartos S, Sarac T, Pomerantz R, et al. Cellular and molecular mechanisms of radiation inhibition of restenosis. PartI: role of the macrophage and platelet-derived growth factor. Int J Radiat Oncol Biol Phys 1998;40:929-41 https://doi.org/10.1016/S0360-3016(97)00937-1
- Sarac TP, Riggs PN, Williams JP, Feins RH, Baggs R, Rubin P, et al The effects of low-dose radiation on neointimal hyperplasia. J Vasc Surg 1995;22:17-24 https://doi.org/10.1016/S0741-5214(95)70083-8
- Metzdorff MT. Intracoronary radiotherapy for restenosis. N Engl J Med 2001;344:1796-7 https://doi.org/10.1056/NEJM200106073442314
- Del Negro A. Bringing vascular brachytherapy to the US forefront: FDA approves two radiation systems for in-stent restenosis. Cardiovasc Radiat Med 2001;2:119-23 https://doi.org/10.1016/S1522-1865(00)00089-5
- SoRelle R. Two intravascular brachytherapy systems approved by FDA. Circulation 2000;102:E9041-3 https://doi.org/10.1161/01.CIR.102.21.e9041
- Sapirstein W, Zuckerman B, Dillard J. FDA approval of coronary-artery brachytherapy. N Engl J Med 2001;344:297-9 https://doi.org/10.1056/NEJM200101253440410
- Albiero R, Nishida T, Adamian M, Amato A, Vaghetti M, Corvaja N, et al. Edge restenosis after implantation of high activity (32)P radioactive beta-emitting stents. Circulation 2000;101:2454-7 https://doi.org/10.1161/01.CIR.101.21.2454
-
Lee DC, Jeong MH, Kim KH, Bom HS, Hong YD, Park KB, et al. The effects of
$^{166}$ Ho-loaded radioactive stent in a porcine model. Korean Circ J 2002;32:479-84 https://doi.org/10.4070/kcj.2002.32.6.479 - Reynen K, Kockeritz U, Kropp J, Wunderlich G, Knapp FF, Schmeisser A, et al. Intracoronary radiotherapy with a (188)rhenium liquid-filled PTCA balloon system in in-stent restenosis: acute and long-term angiographic results, as well as 1-year clinical follow-up. Int J Cardiol 2004;95:29-34 https://doi.org/10.1016/j.ijcard.2003.03.004
-
Park S, Kang WC, Rhee JH, Ko YG, Choi D, Jang Y, et al. Intracoronary
$^{166}$ Holmium brachytherapy combined with cutting balloon angioplasty for the treatment of in-stent restenosis. Cardiovasc Radiat Med 2003;4:119-25 https://doi.org/10.1016/S1522-1865(03)00181-1 - Apple M, Waksman R, Chan RC, Vodovotz Y, Fournadjiev J, Bass BG. Radioactive 133-Xenon gas-filled balloon to prevent restenosis: dosimetry, efficacy, and safety considerations. Circulation 2002;106:725-9 https://doi.org/10.1161/01.CIR.0000023945.21317.27
- Kim W, Jeong MH, Park OY, Rhew JY, Bom HS, Choi SJ, et al. Effects of beta-radiation using a holmium-166 coated balloon on neointimal hyperplasia in a porcine coronary stent restenosis model. Circ J 2003;67:625-9 https://doi.org/10.1253/circj.67.625
- Teirstein PS, Massullo V, Jani S, Popma JJ, Mintz GS, Russo RJ, et al. Catheter-based radiotherapy to inhibit restenosis after coronary stenting. N Engl J Med 1997;336:1697-703 https://doi.org/10.1056/NEJM199706123362402
- Teirstein PS, Massullo V, Jani S, Popma JJ, Russo RJ, Schatz RA, et al. Three-year clinical and angiographic follow-up after intracoronary radiation: results of a randomized clinical trial. Circulation 2000;101:360-5 https://doi.org/10.1161/01.CIR.101.4.360
- Grise MA, Massullo V, Jani S, Popma JJ, Russo RJ, Schatz RA, et al. Five-year clinical follow-up after intracoronary radiation: results of a randomized clinical trial. Circulation 2002;105:2737-40 https://doi.org/10.1161/01.CIR.0000018126.87045.E0
- Waksman R, White LR, Chan RC, Bass BG, Geirlach L, Mintz GS, et al. Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis. Circulation 2000;101:2165-71 https://doi.org/10.1161/01.CIR.101.18.2165
- Waksman R, Cheneau E, Ajani AE, White RL, Pinnow E, Torguson R, et al. Intracoronary radiation therapy improves the clinical and angiographic outcomesof diffuse in-stent restenotic lesions: results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) Studies. Circulation 2003;107:1744-9 https://doi.org/10.1161/01.CIR.0000060497.91775.6D
- Raizner AE, Oesterle SN, Waksman R, Serruys PW, Colombo A, Lim YL, et al. Inhibition of restenosis with beta-emitting radiotherapy: Report of the Proliferation Reduction with Vascular Energy Trial (PREVENT). Circulation 2000;102:951-8 https://doi.org/10.1161/01.CIR.102.9.951
- Leon MB, Teirstein PS, Moses JW, Tripuraneni P, Lansky AJ, Jani S, et al. Localized intracoronary-radiation therapy to inhibit the recurrence of restenosis after stenting. N Engl J Med 2001;344:250-6 https://doi.org/10.1056/NEJM200101253440402
-
Popma JJ, Suntharalingam M, Lansky AJ, Heuser RR, Speiser B, Teirstein PS, et al. Randomized trial of
$^{90}$ Sr/$^{90}$ Y beta-radiation versus placebo control for treatment of in-stent restenosis. Circulation 2002;106:1090-6 https://doi.org/10.1161/01.CIR.0000027814.96651.72 -
Silber S, Popma JJ, Suntharalingam M, Lansky AJ, Heuser RR, Speiser B, et al. Two-year clinical follow-up of
$^{90}$ Sr/$^{90}$ Y beta-radiation versus placebo control for the treatment of in-stent restenosis. Am Heart J 2005;149:689-94 https://doi.org/10.1016/j.ahj.2004.05.061 - Waksman R, Raizner AE, Yeung AC, Lansky AJ, Vandertie L. Use of localised intracoronary beta radiation in treatment of in-stent restenosis. Lancet 2002;359:551-7 https://doi.org/10.1016/S0140-6736(02)07741-3
- Waksman R, Ajani AE, White RL, Chan RC, Satler LF, Kent KM, et al. Intravascular gamma radiation for in-stent restenosis in saphenous-vein bypass grafts. N Engl J Med 2002;346:1194-9 https://doi.org/10.1056/NEJMoa012579
- Kim KI, Bae J, Kang HJ, Koo BK, Youn TJ, Kim SH, et al. Three-year clinical follow-up results of intracoronary radiation therapy using a rhenium-188-diethylene-triamine-penta-acetic-acid- filled balloon system. Circ J 2004;68:532-7 https://doi.org/10.1253/circj.68.532
-
Waksman R, Bhargava B, White L, Chan RC, Mehran R, Lansky AJ, et al. Intracoronary
$\beta$ -radiation therapy inhibits recurrences of in-stent restenosis. Circulation 2000;101:1895-8 https://doi.org/10.1161/01.CIR.101.16.1895 - King SB 3rd, Williams DO, Chougule P, Klein JL, Waksman R, Hilstead R, et al. Endovascular beta-radiation to reduce restenosis after coronary balloon angioplasty: results of the beta energy restenosis trial (BERT). Circulation 1998;97:2025-30 https://doi.org/10.1161/01.CIR.97.20.2025
- Hoher M, Wohrle J, Wohlfrom M, Hanke H, Voisard R, Osterhues HH, et al. Intracoronary beta-irradiation with a liquid (188)re-filled balloon: six-month results from a clinical safety and feasibility study. Circulation 2000;101:2355-60 https://doi.org/10.1161/01.CIR.101.20.2355
- Condado JA, Waksman R, Gurdiel O, Espinosa R, Gonzalez J, Burger B, et al. Long-term angiographic and clinical outcome after percutaneous transluminal coronary angioplasty and intracoronary radiation therapy in humans. Circulation 1997;96:727-32 https://doi.org/10.1161/01.CIR.96.3.727
- Verin V, Urban P, Popowski Y, Schwager M, Nouet P, Dorsaz PA, et al. Feasibility of intracoronary beta-irradiation to reduce restenosis after balloon angioplasty. A clinical pilot study. Circulation 1997;95:1138-44 https://doi.org/10.1161/01.CIR.95.5.1138
- Albiero R, Adamian M, Kobayashi N, Amato A, Vaghetti M, Di Mario C, et al. Short- and intermediate-term results of (32)P radioactive beta-emitting stent implantation in patients with coronary artery disease: The Milan Dose-Response Study. Circulation 2000;101:18-26 https://doi.org/10.1161/01.CIR.101.1.18
- Wardeh AJ, Kay IP, Sabate M, Coen VL, Gijzel AL, Ligthart JM, et al. Beta-Particle-emitting radioactive stent implantation. A safety and feasibility study. Circulation 1999;100:1684-9 https://doi.org/10.1161/01.CIR.100.16.1684
- Jo SH, Kim KI, Koo BK, Lee MM, Park SJ, Seo JB, et al. Long-Term Follow-Up Results of Intracoronary Beta-Radiation Therapy with a Rhenium-188 Diethylene Triamine Penta-Acetic Acid-Filled Balloon. Korean Circulation J 2003;33:723-9 https://doi.org/10.4070/kcj.2003.33.8.723
- Bae JW, Kang HJ, Kim KI, Cho YS, Youn TJ, Koo BK, rt al. Long-Term Effect of Repeated Brachytherapy in Intracoronary Brachytherapy Failed Lesions. Korean Circulation J 2004;34:937-44 https://doi.org/10.4070/kcj.2004.34.10.937
-
Oh SJ, Park SW, Hong MK, Kim YH, Lee SW, Kim MK, et al. Long-Term Outcomes after Treatment of Diffuse In-Stent Restenosis with Rotational Atherectomy Followed by Beta-Radiation Therapy with a
$^{188}$ Re-$MAG_{3}$ -Filled Balloon. Korean Circulation J 2004;34:930-6 https://doi.org/10.4070/kcj.2004.34.10.930 -
Park SW, Kim JH, Choi SC, Hong MK, Moon DH, Oh SJ, et al. Treatment of Diffuse In-stent Restenosis with Rotational Atherectomy Followed by Radiation Therapy with a
$^{188}$ Re-$MAG_{3}$ -Filled Balloon. Korean Circulation J 2001;31:466-75 https://doi.org/10.4070/kcj.2001.31.5.466 - Lee BK, Hong MK, Lee MJ, Kim DS, Lee SW, Park CB, et al. Late Intravascular Ultrasound Findings of Patients Treated with Brachytherapy for Diffuse In-Stent Restenosis. Korean Circulation J 2004;34:856-64 https://doi.org/10.4070/kcj.2004.34.9.856
- Kim SH, Kim HM, Cha KS, Choi DH, Ko YG, Gwon HC, et al. Effect of Vascular BRAchytherapy using HolmiuM-166 Liquid Balloon System after Cutting Balloon Angioplasty in Patients with Stent Restenosis (BRAHMS Study). Korean Circulation J 2005;35:591-6 https://doi.org/10.4070/kcj.2005.35.8.591
- Holmes DR Jr, Teirstein P, Satler L, Sketch M, O'Malley J, Popma JJ, et al. Sirolimus-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents: the SISR randomized trial. JAMA 2006;295:1264-73 https://doi.org/10.1001/jama.295.11.1264
- Stone GW, Ellis SG, O'Shaughnessy CD, Martin SL, Satler L, McGarry T, et al. Paclitaxel-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents: the TAXUS V ISR randomized trial. JAMA 2006;295:1253-63 https://doi.org/10.1001/jama.295.11.1253
- Mukherjee D, Moliterno DJ. Brachytherapy for in-stent restenosis: a distant second choice to drug-eluting stent placement. JAMA 2006;295:1307-9 https://doi.org/10.1001/jama.295.11.1307
- Waksman R, Bhargava B, Mintz GS, Mehran R, Lansky AJ, Satler LF, et al. Late total occlusion after intracoronary brachytherapy for patients with in-stent restenosis. J Am Coll Cardiol 2000;36:65-8 https://doi.org/10.1016/S0735-1097(00)00681-1
- Waksman R, Ajani AE, White RL, Pinnow E, Dieble R, Bui AB, et al. Prolonged antiplatelet therapy to prevent late thrombosis after intracoronary gamma-radiation in patients with in-stent restenosis: Washington Radiation for In-Stent Restenosis Trial plus 6 months of clopidogrel (WRIST PLUS). Circulation 2001;103:2332-5 https://doi.org/10.1161/01.CIR.103.19.2332
- Weinberger J, Amols H, Ennis RD, Schwartz A, Wiedermann JG, Marboe C. Intracoronary irradiation: dose response for the prevention of restenosis in swine. Int J Radiat Oncol Biol Phys 1996;36:767-75 https://doi.org/10.1016/S0360-3016(96)00294-5
- Sabate M, Costa MA, Kozuma K, Kay IP, van der Giessen WJ, Coen VL, et al. Geographic miss: a cause of treatment failure in radiooncology applied to intracoronary radiation therapy. Circulation 2000;101:2467-71 https://doi.org/10.1161/01.CIR.101.21.2467