• Title/Summary/Keyword: Efficiency calibration

Search Result 333, Processing Time 0.025 seconds

The Methodology of Systematic Global Calibration for Process Simulator

  • Lee, Jun-Ha;Lee, Hoong-Joo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.5
    • /
    • pp.180-184
    • /
    • 2004
  • This paper proposes a novel methodology of systematic global calibration and validates its accuracy and efficiency with application to memory and logic devices. With 175 SIMS profiles which cover the range of conditions of implant and diffusion processes in the fabrication lines, the dominant diffusion phenomenon in each process temperature region has been determined. Using the dual-pearson implant model and fully-coupled diffusion model, the calibration was performed systematically. We applied the globally calibrated process simulator parameters to memory and logic devices to predict the optimum process conditions for target device characteristics.

3-Dimensional Calibration and Performance Evaluation Method for Pupil-labs Mobile Pupil Tracking Device (퓨필랩 모바일 동공 추적 장치를 위한 3차원 캘리브레이션 및 성능 평가 방법)

  • Mun, Ji-Hun;Shin, Dong-Won;Ho, Yo-Sung
    • Smart Media Journal
    • /
    • v.7 no.2
    • /
    • pp.15-22
    • /
    • 2018
  • Pupil tracking technologies can be used as an efficient information provider means that provides convenience to the user by connecting with a smart device. In this paper, we measure the distance of user gaze point using the pupil tracking device which produced by Pupil-labs, also shows the experimental result with analyzing accuracy and precision. Based on that the pupil gaze point location which tracked by pupil tracking device is compared with object target in terms of error. Since the mobile pupil tracking device is also one kind of camera, we have to perform the calibration before using the device. Not only generally used 2-dimensional calibration, but also 3-dimensional calibration method is explained. To get the improved accuracy of 2-dimensional calibration result, the 3-dimensional calibration set an imaginary plane and executes the calibration in various 3-dimensional spaces. To show the efficiency of 3-dimensional calibration, we analyze the experimental result. It also introduces various using methods and information that can be obtained through the device.

Neutron Calibration Field of a Bare 252Cf Source in Vietnam

  • Le, Thiem Ngoc;Tran, Hoai-Nam;Nguyen, Khai Tuan;Trinh, Giap Van
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents the establishment and characterization of a neutron calibration field using a bare $^{252}Cf$ source of low neutron source strength in Vietnam. The characterization of the field in terms of neutron flux spectra and neutron ambient dose equivalent rates were performed by Monte Carlo simulations using the MCNP5 code. The anisotropy effect of the source was also investigated. The neutron ambient dose equivalent rates at three reference distances of 75, 125, and 150 cm from the source were calculated and compared with the measurements using the Aloka TPS-451C neutron survey meters. The discrepancy between the calculated and measured values is found to be about 10%. To separate the scattered and the direct components from the total neutron flux spectra, an in-house shadow cone of 10% borated polyethylene was used. The shielding efficiency of the shadow cone was estimated using the MCNP5 code. The results confirmed that the shielding efficiency of the shadow cone is acceptable.

Relationship between porcine carcass grades and estimated traits based on conventional and non-destructive inspection methods

  • Lim, Seok-Won;Hwang, Doyon;Kim, Sangwook;Kim, Jun-Mo
    • Journal of Animal Science and Technology
    • /
    • v.64 no.1
    • /
    • pp.155-165
    • /
    • 2022
  • As pork consumption increases, rapid and accurate determination of porcine carcass grades at abattoirs has become important. Non-destructive, automated inspection methods have improved slaughter efficiency in abattoirs. Furthermore, the development of a calibration equation suitable for non-destructive inspection of domestic pig breeds may lead to rapid determination of pig carcass and more objective pork grading judgement. In order to increase the efficiency of pig slaughter, the correct estimation of the automated-method that can accommodate the existing pig carcass judgement should be made. In this study, the previously developed calibration equation was verified to confirm whether the estimated traits accord with the actual measured traits of pig carcass. A total of 1,069,019 pigs, to which the developed calibration equation, was applied were used in the study and the optimal estimated regression equation for actual measured two traits (backfat thickness and hot carcass weight) was proposed using the estimated traits. The accuracy of backfat thickness and hot carcass weight traits in the estimated regression models through stepwise regression analysis was 0.840 (R2) and 0.980 (R2), respectively. By comparing the actually measured traits with the estimated traits, we proposed optimal estimated regression equation for the two measured traits, which we expect will be a cornerstone for the Korean porcine carcass grading system.

Characteristics of Driving Efficiency and Bearing Capacity for Long Steel Pipe Pile Method without Welding (무용접 장대강관말뚝 공법의 항타 및 지지력 특성)

  • 백규호
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.235-241
    • /
    • 2000
  • The existing methods for installation of long steel pipe pile have some uneconomical problems such as increase of installation cost and period due to the welding of two piles and removal of soil plug, and decrease of driving efficiency due to the increase of driving resistance resulting from time effect during the welding of piles and removal of soil plug, etc. Thus, in this study, new installation method for long steel pipe pile is suggested to solve the existing problems, and calibration chamber tests were performed to investigate both driving and economical efficiency for the suggested method. The test results showed that the new method increased bearing capacity, and decreased the installation cost and period for long steel pipe piles compared with existing methods.

  • PDF

Wireless Networked System for Transmission Path Self-Calibration of Laser Equipment (레이저 장비의 전송 경로 자가 교정을 위한 무선 네트워크 시스템)

  • Lee, Junyoung;Yoo, Seong-eun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.2
    • /
    • pp.79-85
    • /
    • 2020
  • IIoT stands for Industrial Internet of Things used in manufacturing, healthcare, and transportation in networked smart factories. Recently, IIoT's environment requires an automated control system through intelligent cognition to improve efficiency. In particular, IIoT can be applied to automatic calibration of production equipment for improved management in industrial environments. Such automation systems require a wireless network for transmitting industrial data. Self-calibration systems in laser transmission paths using wireless networks can save resources and improve production quality by real-time monitoring and remote control of laser transmission path. In this paper, we propose a wireless networked system for self-calibration of laser equipment that requires a laser transmission path, and we show the results of the prototype evaluation. The self-calibration system of laser equipment measures the coordinates of the laser points with sensors and sends them to the host using the proposed application protocol. We propose a wireless network service for the wired motor controller to align the laser coordinates. Using this wireless network, the host controls the motor by sending a control command of the motor controller in an HTTP message based on the received coordinate values. Finally, we build a prototype system of the proposed design to verify the detection performance and analyze the network performance.

Simulation of Sediment Yield from Imha Watershed Using HSPF (HSPF를 이용한 임하호 유역 유사량 모의)

  • Jeon, Ji-Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.6
    • /
    • pp.39-48
    • /
    • 2010
  • Sediment yields from Imha watershed were simulated during 1993-2008 using Hydrologic Simulation Program-Fortran (HSPF). Using observed daily stream flow for 2004-2008 and hourly suspended solid concentration for three events during 2006, HSPF was calibrated and validated at the sites of Imha and Youngyang for stream flow and Dongchun and Jangpachun for sediment yield. The calibration and validation results represented high model efficiency for simulating daily stream flow and hourly suspended solid. The determination coefficients of calibration and validation were 0.90 and 0.81 for daily stream flow, and 0.91 and 0.86 for monthly stream flow, respectively. Based on model tolerances for calibration and validation of stream flow, HSPF performance for simulating stream flow represented 'very good'. The determination coefficients of calibration and validation were 0.94-0.96 and 0.95 for hourly sediment yields, respectively. The average yearly sediment yield during 1993-2008 was 122,290 ton/year and most of sediment yield (77 % of total yield) were generated from June to August. The calibrated HSPF simulated well the movement of water and eroded soil within Imha watershed.

Hydrologic Calibration of HSPF Model using Parameter Estimation (PEST) Program at Imha Watershed (PEST를 이용한 임하호유역 HSPF 수문 보정)

  • Jeon, Ji-Hong;Kim, Tae-Il;Choi, Donghyuk;Lim, Kyung-Jae;Kim, Tae-Dong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.802-809
    • /
    • 2010
  • An automatic calibration tool of Hydrological Simulation Program-Fortran (HSPF), Parameter Estimation (PEST) program, was applied at the Imha lake watershed to get optimal hydrological parameters of HSPF. Calibration of HSPF parameters was performed during 2004 ~ 2008 by PEST and validation was carried out to examine the model's ability by using another data set of 1999 ~ 2003. The calibrated HSPF parameters had tendencies to minimize water loss to soil layer by infiltration and deep percolation and to atmosphere by evapotranspiration and maximize runoff rate. The results of calibration indicated that the PEST program could calibrate the hydrological parameters of HSPF with showing 0.83 and 0.97 Nash-Sutcliffe coefficient (NS) for daily and monthly stream flow and -3% of relative error for yearly stream flow. The validation results also represented high model efficiency with showing 0.88 and 0.95, -10% relative error for daily, monthly, and yearly stream flow. These statistical values of daily, monthly, and yearly stream flow for calibration and validation show a 'very good' agreement between observed and simulated values. Overall, the PEST program was useful for automatic calibration of HSPF, and reduced numerous time and effort for model calibration, and improved model setup.

Feasibility Study on Development of an Underwater Beta-ray Monitoring Sensor (수중 내 베타선 모니터링 센서 개발을 위한 기초연구)

  • Park, Hye Min;Joo, Koan Sik
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.333-336
    • /
    • 2016
  • In this study, a beta monitoring sensor was developed as a part of basic research for quantitative beta monitoring underwater, and its performance was evaluated using a calibration source. A beta detection sensor was manufactured by using SiPM(silicon photomultiplier) and $CaF_2$:Eu, YAG:Ce, YAP:Ce scintillator. A large-area light guide was introduced to improve beta-ray detection efficiency. As calibration sources, the Beta source $^{90}Sr$, which is the main fission product of a nuclear accident, and the gamma source $^{137}Cs$ are used. In the performance evaluation, it is confirmed that scintillator $CaF_2:Eu$ gives the highest beta-ray detection response. Compared to gamma ray, beta-ray detection responsivity and detection efficiency are verified. Therefore, this study is expected to contribute to basic research in the development of an underwater beta-ray monitoring system.

A Study on the development and calibration method of a modular internal resistance meter to improve the safety of reusable batteries

  • Mi-Jin Choi;Sang-Bum Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.228-235
    • /
    • 2024
  • Battery use is increasing worldwide to achieve carbon neutrality and improve energy efficiency, but batteries are a finite resource and their application is determined by capacity and specifications. Battery performance deteriorates as the number of uses increases. A certain level of battery performance degradation has become an issue in the field of reuse and recycling, and various studies are being conducted on reuse to solve power shortages. Waste batteries from electric vehicles are suitable for building ESS based on reusable batteries, and for stable use, technical skills are needed to accurately predict battery life and determine status information. Predicting battery life and determining status information are difficult due to non-linearity due to internal structure or chemical changes. In this paper, we manufactured a modular internal resistance measuring device and compared the measured values with Hioki equipment to minimize the error rate through a correction method. As a result of testing Hioki equipment and modular measuring instruments to ensure efficiency and safety based on reusable batteries, an accuracy of over 95% was confirmed.