• 제목/요약/키워드: Effective wiring method

검색결과 15건 처리시간 0.019초

외상성 내안각격리증 환자에 있어 Hiraga 절개법을 이용한 내안각 고정술 (Medial Canthopexy using Modified Hiraga's Incision for Correction of Traumatic Telecanthus)

  • 임종효;김용하;김태곤;이준호
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.504-508
    • /
    • 2010
  • Purpose: Traumatic telecanthus can result from nasoethmoid-orbital fractures. Repair of the medial canthal tendon (MCT) using transnasal wiring is regarded as a choice of method to treat telecanthus, however, is often complicated by incomplete anchoring and drift of canthus, extrusion of wire, in-fracture of orbital bone, and eye damage. The authors introduced oblique transnasal wiring method through the Hiraga's epicanthopalsty incision instead of well-known classical bicoronal approach. Methods: Five patients with traumatic telecanthus were treated with this method. Though the Hiraga's epicanthoplasty incision, we could approach the operative field; the medial orbital wall and detached MCT. Oblique transnasal wiring was performed as following steps. After slit skin incision on the contralateral nasal recession area, drill holes were made from this point to the superior and posterior point of lacrimal sac of deformed eye. A 2-0 wire was double-passed through the holes and MCT. Traction was applied to ensure pulling the MCT and the wires were twisted in the contralateral nose, securing the MCT in the correct position. Results: All patients except 1 person showed improvement and rapid recovery. On average each canthus was moved 5.6 mm medially. In all cases, there were no eyelashes disappear, lacrimal canaliculitis, lacrimal duct injury, or infections. Conclusion: The Hiraga's epicanthoplasty incision could give sufficient operative field to reattach the MCT in traumatic telecanthus patients. And the oblique transnasal wiring technique is effective for the Asians who have flat nose and exophthalmic eye. The authors conclude that this technique could be a simple, safe and scarless method to correct traumatic telecanthus.

SPD의 설치조건이 보호효과에 미치는 영향 (Protection Effects Associated with the Conditions for the Installations of SPDs)

  • 이복희;이동문;이승칠
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.60-67
    • /
    • 2006
  • 이 논문은 서지보호기의 설치조건에 따른 보호효과에 대하여 기술하였으며, 뇌서지로부터 정보통신설비를 효과적으로 보호하는 설치기법을 제안하기 위해 서지보호기의 보호효과에 미치는 설치위치, 분기회로의 길이, 배선방법, 전선관 재료의 영향에 대해서 실규모 조건에서의 실험을 수행하였다. 그 결과, 보호하고자 하는 각각의 전자기기의 입력단에 서지보호기를 설치하는 것이 효과적이며, 선간에 서지보호기를 설치할 때는 접속선의 길이가 최소가 되도록 하는 배선방법이 효과적이다.

전원계통의 접지방식 및 배선방식에 따른 서지보호기의 효과 (REffects of Surge Protective Devices with Respect to Types of System Grounding and Wiring Methods)

  • 이수봉;이복희;길형준
    • 조명전기설비학회논문지
    • /
    • 제18권2호
    • /
    • pp.90-99
    • /
    • 2004
  • 고도 정보화 사회의 발달과 함께 정보통신 설비는 빠른 전송속도를 필요로 하며, 지능형 산업설비와 행정, 금융, 교통시스템과 같은 사회시스템은 집적회로와 초소형 반도체로 구성되므로 원격감시, 조작에 의해 점차적으로 자동화 되어가고 있다. 이와 같은 현대의 초소형 전자회로는 뇌 서지에 의해 흔히 손상을 입을 수 있으며, 뇌 과전압으로부터 전자회로의 보호에 관심이 집중되고 있다. 본 논문은 일반주택에서 뇌 서지로부터 초소형 컴퓨터와 같은 전자기기의 효과적인 보호방법을 제안하기 위하여 전원계통의 접지방식에 따른 서지보호기의 보호효과를 실험적으로 분석하였다. 또한 서지보호기의 효과적인 설치방법을 조사하고 제안하였다. 기존의 설비에 추가적으로 서지보호기를 설치하는 것은 서지보호기까지의 긴 접속선으로 인한 인덕턴스 때문에 높은 잔류전압이 나타난다. 서지보호기의 설치에 있어 두 접속선을 꼬는 방법이 급격하게 상승하는 과도과전압에 매우 효과적이다.

정보화 기기용 SPD의 설치조건에 따른 보호효과 (Protection Effects According to the Conditions of Installations of SPDs for Information-Oriented Equipments)

  • 이복희;이동문;정동철;이수봉;이승칠
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.35-41
    • /
    • 2007
  • 최근 고품질의 정보통신서비스와 안정한 전력공급에 대한 사회적 요구가 증가하고 있다. 본 연구에서는 뇌서지로부터 정보통신설비를 효과적으로 보호하는 대책을 제안하기 위해서 실규모 실험회로를 적용하여 여러 가지 설치조건에 따른 서지보호기의 보호효과를 실험적으로 조사하였다. 그 결과 전원계통의 접지방식, 분기회로의 수, 접지선의 배선방법 등에 따라 서지보호기의 보호효과는 크게 다른 것으로 밝혀졌다. 정보화 기기용 서지보호기를 설치하는 경우, 전원선과 통신선을 포함하는 공통접지방식과 접지선을 전원선과 일괄하여 금속관 내에 배선하는 것이 서지보호기의 서지차단성능의 향상에 가장 효과적이었다.

VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석 (Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire)

  • 김두현;김성철;이종호;박종영;박영호;이형준
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.47-52
    • /
    • 2008
  • Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

복수시스템 제어를 위한 멀티플랙싱 기법 개발 (Development of a Multiplexing Method for Multi-System Control)

  • 오동진;윤상진;조용석;박기헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2542-2544
    • /
    • 2000
  • In this paper, CAN(Controller Area Network)is used to solve the wire harness problem in the outside mirror of automobile which has a lot of functions in narrow space. If the number of wires is reduced, it has benefits of lower product cost and maintenance. CAN was originally developed by the German company Robert Bosch for use in the car industry to provide a cost-effective communications bus for in car electronics and as alternative to expensive and cumbersome wiring looms. CAN controller is a serial communication protocol which efficiently supports distributed real-time control with a very high level of security. The communication between master CAN controller and slave CAN controller is realized and controller's performance is tested by experiment.

  • PDF

Cause Analysis and Improvement of Signal Interference in Byteflight Data Bus

  • Kwon, Jung-Hyuk;Tak, Su-Pyeong;Kwon, Ik-Hyun;Lee, Wang-Sang
    • 항공우주시스템공학회지
    • /
    • 제15권6호
    • /
    • pp.50-58
    • /
    • 2021
  • Byteflight is developed based on RS-485 communication (an international standard), and it can be used as a data bus during the operation of an integrated avionics system in the latest aircraft. Therefore, the integrated avionics system can perform an effective and safe flight mission only when the accurate and seamless display of flight information, communication, and accurate functions of navigation are implemented. In this study, cause analysis and failure investigation were performed on screen abnormalities and communication interruptions due to signal interference in the Byteflight data bus of the integrated avionics system during aircraft operation. To improve signal interference between avionics units, the branch point and wiring path of the Byteflight data bus were changed, and the verification result of the improved method was also described.

쇄골 외측단 Rockwood 제2형 골절의 치료 (Treatment for the Rockwood type Ⅱ Fractures of Lateral End of Clavicle)

  • 오창욱;경희수;박건욱
    • Clinics in Shoulder and Elbow
    • /
    • 제1권1호
    • /
    • pp.66-71
    • /
    • 1998
  • The fractures of lateral end of clavicle can be treated by conservative or operative treatment, but many authors report the higher rate of non-union with conservative treatment and that the operative treatment is more effective for the type II fractures. The authors reviewed and analysed 15 cases of lateral end fracture of clavicle which had been treated at Department of Orthopedic Surgery, Kyungpook National University Hospital from 1991 to 1996. The results were as follows; 1. Among the 15 patients, male was 6,female 9 and the average age was 46.2 years ranged from 21 to 72 years. 2. According to the classification by Rockwood, type II a was 8 cases and II b was 7 cases. 3. We treated operatively 12 cases, 9 cases with tension band wiring and 3 cases with intramedul-Iary K-wire fixation. And we treated conservatively 3 cases with Velpeau cast, but I case of nonunion was treated with tension band wiring. 4. The average follow-up was 3.2 years ranged from 2.1 to 4.7 years. 5. The functional results were evaluated with Weitzman's classification. 6. In the operatively treated cases, there were 4 cases(30.7%) in excellent, 7 cases(53.8%) in good and 2 cases(15.3%) in fair result. But, in the conservatively treated cases, there were 2 cases in good and I case in poor result, and the poor case did not united and had open reduction and internal fixation. 7. In conclusion, the operative treatment revealed good functional results in most cases (10/12) and early open reduction and internal fixation was better method than conservative treatment.

  • PDF