• Title/Summary/Keyword: Effect Measurement

Search Result 6,936, Processing Time 0.038 seconds

Stability of Gas Response Characteristics of IGZO (IGZO 박막의 CO2 가스 반응에 대한 안정성)

  • Oh, Teresa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.17-20
    • /
    • 2018
  • IGZO thin films were prepared on n-type Si substrates to research the interface characteristics between IGZO and substrate. After the annealing processes, the depletion layer was formed at the interface to make a Schottky contact owing to the electron-hall fair recombination. The carrier density was decreased by the effect of depletion layer and the hall mobility decreased during the deposition processes. But the annealing effect of depletion layer increased the hall mobility because of the increment of potential barrier and the extension of depletion layer. It was confirmed that it is useful to observe the depletion effect and Schottky contact's properties by complementary using the Hall measurement and I-V measurement.

Development of Paper Blood Glucose Sensor with Minimal Hematocrit Effect (헤마토크릿 영향을 최소화한 종이 혈당센서 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.116-120
    • /
    • 2022
  • In this paper, we developed a paper blood glucose sensor that can minimize the effect of hematocrit. The paper blood glucose sensor has the advantage of being very simple in its production process as it is manufactured with only three printing processes on the top of the paper substrate. This glucose sensor consists of a total of six electrodes, including blood glucose measurement electrodes, hematocrit measurement electrodes, strip detection electrodes, and blood detection electrodes. A paper blood glucose sensor measures hematocrit with electrodes formed on the same sensor substrate when measuring blood glucose concentration, and compensates for the effect of hematocrit in real time to enable accurate blood glucose measurement.

One-way ANOVA Analysis to Verify the Effect of Hybrid Strength Estimators by Number of Measurements (일원분석을 통한 하이브리드 추정계의 측정횟수별 영향검증)

  • Han, Soo-Hwan;Hu, Yun-Yao;Kim, Su-Ho;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.37-38
    • /
    • 2022
  • This study is attempted to propose an appropriate number of measurements by checking and statistically analyzing the change in hardness according to the number of measurements. As a result, there was no significant difference between the 20th and 30th data, and in the 10th case, the effect on errors occurring during measurement was found to be dominant. Therefore, as the number of measurements, proposing 20 times in consideration of the convenience of use. In addition, in order to minimize the effect on the measurement error, it is proposed to remeasure the surface mane of the measurement surface and the test value in which the error occurs on the average of the test values.

  • PDF

Black Carbon Measurement using a Drone (드론을 활용한 대기 중 블랙카본 농도 측정)

  • Lee, Jeonghoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.486-492
    • /
    • 2018
  • Black carbon concentrations were measured along the altitude at various locations using a drone coupled with a small black carbon detector. The measurement locations are Eunseok Mountain, downtown, four places in KOREATECH campus, Byeongcheon, Cheonan, Chungcheongnam-do, and Chungbu Expressway in Ochang-eup, Cheongju, Chungcheongbuk-do. The average concentration of black carbon measured in Eunseok Mountain was $1.64{\mu}g/m^3$ and the average concentration near the Chungbu Expressway was measured to be $3.86{\mu}g/m^3$. The average concentrations of four places inside campus ranged from 1.37 to $2.67{\mu}g/m^3$. The concentration of black carbon at all places tended to be slightly decreased according to the altitude, but the influence of pollution source, geometry, wind speed, and wind direction are thought to be larger than the effect of altitude. Effect of air flow caused by drone flight on the measurement of black carbon were investigated and it resulted in that the measurement of BC concentration was affected by less than 5%.

The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement (간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.

Gain-scheduling of Acceleration Estimator for Low-velocity Measurement with Encoders

  • Son, Seung-Woo;Lee, Sang-Hun;Hur, Jong-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1853-1857
    • /
    • 2005
  • In most of motor-driven motion control systems, an encoder is used to measure a position of the motor and the velocity information is obtained by measuring the position increment over a sampling period. The quantization effect due to limited resolution of the encoder induces some measurement errors, and consequently causes deterioration of the motion performance especially in low velocity. In this paper, we propose a gain-scheduled acceleration estimator which works in wider velocity range than the original acceleration estimator. We investigate and analyze characteristics of the velocity measurement mechanism which takes into account the quantization effect of the encoder. Next, we introduce the acceleration estimator and propose a gain-scheduled acceleration estimator. The bandwidth of the gain-scheduled acceleration estimator is automatically adjusted by the velocity command. Finally, its performance is evaluated by simulation and experiment, and the results are compared with those of a conventional method and the original acceleration estimator.

  • PDF

Non-contact critical current measurement of superconducting coated conductor using Hall Probe (Hall Probe를 이용한 초전도선재의 비접촉 임계전류 측정 방법)

  • Kim, Ho-Sup;Oh, Sang-Soo;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Ko, Rock-Kil;Ha, Hong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.12-12
    • /
    • 2010
  • The hall probe measurement system was used to measure the critical current distribution of superconducting coated conductor. The system consists of reel to reel moving apparatus, 7 array hall probe, a rotary encoder and permanent magnet. The magnetic field profile across the width of superconducting coated conductor using Bean's critical state model was calculated. The effect of various parameters of the formulas on the magnetic field distribution and the effect of shape and size of artificial defects, which were formed on the surface of SmBa2Cu3O7-d(SmBCO) coated conductor using laser marking system, on the hall probe magnetic field signal of the hall probe measurement system was investigated.

  • PDF

Development of AC Resistance Measurement System (교류저항 측정시스템 개발)

  • Kim, Han-Jun;Yu, Kwang-Min;Kang, Jeon-Hong;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.683-684
    • /
    • 2008
  • The resistance is frequency dependent by the Seeback effect, loading effect, Eddy current loss, uniformly distributed inductance of the resistance element and uniformly distributed self-capacitance of the resistance element and capacitance between resistance element and it's box. A precise ac resistance measurement system has been developed for using as maintaining and dissemination of national ac resistance standards. The developed resistance measurement system can be used as a instrument of national ac resistance standards at frequency less than 10 kHz and it's measurement accuracy was 0.23(${\mu}{\Omega}/{\Omega}$)+4.2 ${\mu}{\Omega}$ at 1592 Hz and 20 V.

  • PDF

A Literature Review of the Effectiveness Measurement for NCW (NCW 효과측정에 관한 문헌조사 연구)

  • Jung, Chi-Young;Lee, Jae-Yeong
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.37 no.2
    • /
    • pp.1-16
    • /
    • 2012
  • NCW(Network Centric Warfare) offers BSEs(Battelspace-Entities) the capabilities of sharing information through C4ISRCommand, Control, Communications, Computers and Intelligence, Surveillance and Reconnaissance) network and it also improves their combat powers based on information superiority with awareness of common situation in battlefield and self-synchronization. Although the concept of NCW was developed at the end of 1990 and there have been various studies for NCW from the development of its concept, the effort for measuring the synergistic effect of NCW is insufficient at the present time. Therefore, in this paper we reviewed literatures concerning the effectiveness measurement of NCW. The category of our survey is network effect, metrics, simulation, battlefield information, social network analysis and mathematical model. The main purpose of this study is to suggest future researchers a research direction by analyzing the aspects and limitations of existing studies about the quantitative measurement of NCW.

Basic Examination on 3D Measuring System Using Pulse-Compression

  • Fujimoto Ikumatsu;Ando Shigeru
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.4
    • /
    • pp.60-66
    • /
    • 2005
  • In this paper, we propose the basic measurement method of a 3D digitizer using a CCD camera in detail. In the localization measurement with a CCD camera, the effect of the background light and the sensitivity consideration are always problems in realizing a high precision. In this research, a new measurement principle is proposed in which the pulse compression technique known in radar is used to eliminate the effect of background light even under a low intensity light source, and the coordinate values on the CCD camera image plane are determined accurately. From the quantitative evaluation of the S/N ratio improvement and the fundamental experiment, it is verified that a substantial improvement in the S/N ratio is realized for both the background noise and the pixel noise and that a resolution of less than the pixel is sufficiently possible.