• Title/Summary/Keyword: Effect Measurement

Search Result 6,936, Processing Time 0.037 seconds

Design and Analysis of a Switching State Feedback Controller to Reduce the Measurement Error Effect for a Chain of Integrators System under AC and DC Noise (AC와 DC 노이즈가 있는 적분기 시스템에서 측정에러의 영향을 감소시키는 스위칭 상태 궤환 제어기의 설계 및 분석)

  • Oh, Sang-Young;Choi, Ho-Lim
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.1
    • /
    • pp.12-17
    • /
    • 2014
  • In this paper, we propose a controller capable of reducing the effect of measurement errors under AC and DC noise. Typically, the control system measures data through a sensor. If sensor noise is included in a controller via the feedback channel, the signal is distorted and the entire system cannot work normally. Therefore, some appropriate action to counter the measurement error effect is essential in the controller design. Our controller is equipped with a gain-scaling factor and a compensator to reduce the effect of measurement error in the feedback signal. Also, we use a switching control strategy to enhance the performance of the controller regarding convergence speed. Our proposed controller can therefore effectively reduce the AC and DC noise of the sensor. We analyze the proposed controller by Laplace transform technique and our control method is verified via MATLAB simulation.

Simulated Indoor Pass-by 시스템에서의 최적 Microphone Array 형태와 검증

  • Yu, Yun-Seon;Shirahashi, Yoshihiro;Morie, Daisuke
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.225-228
    • /
    • 2009
  • The simulated indoor pass-by noise measurement system is the tool to measure and evaluate the pass-by noise at the test laboratory, without doing measurement at the field. This measurement system can realize the precision measurement under the specific condition and overcome the limitations of the field measurement, i.e. weather conditions, repeatability, .. This measurement system is done in time domain process using the array techniques, which synchronizes the time signals. The reliability of the obtained result depends on the array shapes, which can generate the moving source effect. In this paper, the validations are checked focusing the time domain synchronization of the signals with the optimum microphone array shape.

  • PDF

A Case Study on Economic Effect of KPI for TPM Performance Measurement (사례를 통한 TPM 성과측정 KPI의 경제적 효과 산출 방법)

  • Oh, Sangyoung;Son, Yangkyun;Suh, Yongsung;Jeong, Seonphil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5044-5051
    • /
    • 2012
  • TPM(Total Productive Maintenance) is a methodology to improve corporations' productivity and has been employed widely. At the initial stage of the TPM, we need to set basic plans and goals of the TPM. Also, quantization of performance is required through the TPM activity measurement indices to achieve the plans and the goals. We analyzed measurement factors of TPM activity by observation of previous researches and suggest a measure methodology of economic effect for the TPM performance measurement based on BSC and quantification of qualitative measurement.

A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field (현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교)

  • An, Seung-Hee;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

Effect of a Butterfly Valve on the Uncertainty of Flow Rate Measurement (버터플라이 밸브의 유량측정 불확도에 대한 영향)

  • Yoon, Seok-Ho;Lee, Jung-Ho;Yu, Cheong-Hwan;Park, Sang-Jin;Chung, Chang-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.18-24
    • /
    • 2010
  • For testing large-capacity pumps, the accurate flow rate measurement is needed in the test loop. As a measuring method of flow rate, venturi tube is recommended due to its low pressure loss. However, upstream disturbance of loop component such as a valve has an effect upon the accuracy of flow rate measurement. For controlling flow rate in case of high flow rate and large-scale piping system, a butterfly-type valve is generally used due to its compactness. However, a butterfly valve disturbs downstream flow by generating turbulence, cavities, or abrupt pressure change. In this study, the effect of downstream disturbance of butterfly valve on the flow rate measurement using a venturi tube is investigated. Test loop consists of circulation pump, reservoir, butterfly valve, venturi tube, and reference flow meter. The test is conducted with regard to a different valve opening angle of butterfly valve. According to the valve opening angle, the uncertainty of flow rate measurement is investigated.

A Proposal of Combat Power Measurement Model of Army Warfare Information System Using Network Power based on Social Network Analysis (SNA 기반 네트워크 파워를 이용한 지상전장정보체계 전투력 효과측정 모델제안)

  • Jung, Chi-Young;Lee, Jae-Yeong
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.36 no.4
    • /
    • pp.1-16
    • /
    • 2011
  • It is important not only to introduce the C4I(Command and Control, Communication, Computer, Intelligence) system for realizing the NCW(Network Centric Warfare) but also to evaluate the synergistic effect by the C4I system. However, the study effort for evaluating the system's synergistic effect is insufficient compared with introducing the system. Therefore, in this paper, we proposed a model that measures the synergistic effect of combat power by the warfare information system. To measure the synergistic effect of warfare information system, the network power must be considered, so we also proposed a new methodology for measurement of network power based on SNA(Social Network Analysis), not Metcalfe's law. A model we proposed is a model that measures the raised combat power by the network effectiveness. The methodology and model we proposed in this paper will be used usefully to analyze the practical effect of constructing future warfare information system.

Review of Researches in Concept, Measurement, Effect, and Influence Factor of Teacher Efficacy (교사효능감의 개념, 측정, 효과, 영향요인에 대한 연구동향)

  • JU, Dong-Beom
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.21 no.4
    • /
    • pp.489-498
    • /
    • 2009
  • The purpose of the study is to review research in concept, measurement, effect, and influence factor of teacher efficacy. Through the review of previous research, the study shows that the concept of teacher efficacy is likely to be situation-specific rather than teacher characteristic. And the study represents that the measurement of teacher efficacy is related to the development of measurement instrument and the extraction of construct. The effect of teacher efficacy concerns the relationship between teacher efficacy and the student's academic achievement and affective traits such as motivation, interests, and attitude, and the relationship between teacher efficacy and teacher. And the influence factor of teacher efficacy concerns the influence of job environment related to teacher. The four things mentioned above are discussed in detail based on the previous research.

Review on Current Status of Use and Measurement Condition of Heart Rate Variability in Clinical Study of Korean Medicine (한의학 임상연구에서의 심박변이도 검사 활용현황과 측정조건에 대한 고찰)

  • Kim, Sang-Ho
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.127-137
    • /
    • 2012
  • Objectives : The purpose of this study is to review on current status of use and measurement condition of heart rate variability(HRV) by reviewing clinical studies published in journal of Korean medicine registered Korea citraion index(KCI). Methods : One hundred twenty articles were found by searching the representative Korean databases. At first analysis was performed by current status of use(journal, academic field of corresponing author, purpose of study, disease of subject, HRV measurement devices, intervention methods and tests compared to HRV). At second analysis was performed by measurement condition(uncontrolled study, relaxation before measurement, measurement position, measurement place, measurement time period and restriction of smoking, alcohol, caffeine, meal). Results : The analysis showed that department of acupuncture & moxibustion, department of oriental neuropsychiatry are major part in journal & academic field. The purpose of study were classified under studies to verify therapeutic effect on normal subject(39%), to verify therapeutic effect on the patients(8%), to investigate characteristics of the patients(34%) and to be compared with other test(19%). Disease of subject & measurement devices in article were so various. Major intervention methods were acupuncture(61.4%), mind-body intervention(19.2%). Studies that measurement condition were not controlled were relax time(24%), measurement position(19%), measurement place(26%), measurement time period(91%) and restriction of smoking, alcohol, caffeine, meal(49%). Conclusions : This study showed that current status of use of HRV is widespread in Korean medicine but more controlled measurement conditon are needed to get more reliable result from clinical studies and to improve diagnosis and treatment of Korean medicine.

Effects of Geometric Errors on the Measurement of Error Motions of Rotor with the Cylindrical Capacitive Displacement Sensor (형상오차가 원통형 정전용량 변위센서의 축 회전오차의 측정에 미치는 영향)

  • 안형준;장인배;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.487-490
    • /
    • 1995
  • This paper discisses the effects geometric errors on the measurement of error motions of rotor with the cylindrical capacitive displacement sensor. Analytic model of the measuring process with this sensor is derived and this model shows that the effect of geometric errors of sensor is larger than that of rator on the measurement of error motions of rotor. The computer simulation shows effect of periodic errors in this sensor on the measuring orbit.

  • PDF

Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters

  • Lee, Chang-Hee;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.383-391
    • /
    • 2014
  • For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.