• Title/Summary/Keyword: Edentulous Patients

Search Result 374, Processing Time 0.026 seconds

A 5-year prospective clinical study of Neobiotech implants for partially edentulous patients (부분 무치악환자에서 Neobiotech 임플란트의 5년 전향적 임상연구)

  • Labriaga, Wilmart;Hong, Ju-Hee;Park, Jin-Hong;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.272-278
    • /
    • 2017
  • Purpose: The aim of the present prospective clinical study was to assess the cumulative survival rate (CSR) of Neobiotech implants restored with fixed partial prosthesis in relation to its potential risk factors. Materials and methods: Thirty six partially edentulous patients received Neobiotech implants and implant supported fixed partial prosthesis at Korea University Guro Hospital Dental Center from November 2009 until November 2011. The observation period was set from the implant placement and the last clinical visit until December 2015. Implant survival rate was determined using the Kaplan-Meier method. The relationship between implant survival rate and the potential risk factors were analysed using the multi Cox proportional analysis (P<.05). Results: A total of 69 implants were placed in 36 patients after a mean observation period of 45.9 months. Two out of 69 implants failed before loading, yielding a 5-year cumulative survival rate of 97.1%. The maxillary implants have a lesser CSR than the mandibular implants based on log rank test analysis (maxilla=91.3%; mandible=100% P<.05). However, the multi Cox proportional analysis showed that implant location has no significant correlation with implant failure (P>.05). Conclusion: Neobiotech implants showed predictable results with a 5 year cumulative survival rate of 97.1%.

A STUDY ON THE DEGREE OF OCCLUSAL CONTACT UNDER THE FIXEDIMPLANT PROSTHESIS OF PARTIALLY DENTULOUS PATIENTS (부분 무치악 고정성 임플랜트 보철하에서 교합접촉정도에 관한 연구)

  • Song, Keum-Young;Kay, Kee-Sung;Cjung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.281-299
    • /
    • 1995
  • The purpose of this study was to evaluate the degree of occlusal contact under the fixed implant prosthesis of partially edentulous patients which was hased on occlusal concept of implant prosthesis. From the patients who have free-standing implant supported prosthesis of unilateral partially edentulous area, occlusal and occlusal contact point of th enatural tooth side and implant side of light closure and heavy closure were analyzed by T-scan system throuht pre-and post-adjustment and the degree of occlusal contact was estimated by Shimstock. The following results were obtained : 1. The occlusal force of natural tooth side(NF) from mid-sagittal axis was relatively constant at light and heavy closure through pre-and post-adjustment, but the occlusal force of implant side(IF) was decreased significantly at light closure(P<0.01) and heavy closure(P<0.05) of post-adjustment. 2. Natural tooth side-implant side moment(MIMoment) fo occlusal force from mid-sagittal axis was significant(p<0.05) through pre-and post-adjustment and the deviation from mid-sagittal axis was increased at light closure of post-adjustment, but was decreased at heavy closure of post-adjustment. 3. Comparing the NF and IF, IF was greater at heavy closure of pre-adjustment, and NF was greater at light closure of post-adjustment, and the NF and IF was relatively equally distributed at light closure of pre-adjustment and at heavy closure of post-adjustment. 4. The number of occlusal contact point of natural tooth side(NC) was relatively constant through pre-and post-adjustment, but the number of occlusal contact point of implant side(IC) was significantly decreased(P<0.05) at light closure of post-adjustment, and was not significant but was lesser at heavy closure of post-adjustment. 5. Difference of the NC and IC was greater at light closure of post-adjustment, but it was less at heavy closure of post-adjustment, and therefore occlusal contact point of natural tooth side and implant side was relatively equally distributed at heavy closure of postadjustment. 6. When bilaterally distribution of occlusal force and occlusal contact point was established, degree of occlusal contact of implant suporoted prosthesis with opoosing teeth at light clousre was $34.13{\pm}21.69{\mu}m$.

  • PDF

STABILITY CHANGES OF IMMEDIATELY LOADED AND DELAYED LOADED IMPLANTS IN EDENTULOUS MANDIBLE (하악 무치악에서 즉시하중과 지연하중간 임플랜트의 안정성 변화)

  • Jung, Hye-Eun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.250-262
    • /
    • 2007
  • Statement of problem: It was reported high success rate of implant-supported fixed prostheses using with $5{\sim}6$ implants on anterior mandible. Recently, immediate loading protocol was focused to overcome disadvantages of classic 2-stage delayed loading protocol. Purpose: This clinical study was to evaluate stability changes with time of immediately loaded and delayed loaded implants in edentulous mandible and to compare stability changes with time according to implantation sites. Materials and methods: Five or six implants were placed on anterior mandible depending on the arch shape. The immediately loading group was consisted of 8 patients received their prostheses within $24{\sim}48$ hours after implantation. The delayed loading group was consisted of 8 patients received their definitive prostheses following classical prosthetic procedures after a healing period of 3 months. All patients were recalled every 6 months for check-up. The evaluations of radiographic examination, ISQ value measurement and recording of complication were done. To evaluate marginal bone level, intraoral periapical radiographs were taken with long cone paralleling technique. At every evaluation recall, all prostheses were removed and ISQ values were measured with OsstellTM on individual implants. Results: 1. None of implants was failed. All implants showed stable marginal bone levels and ISQ values. 2. Marginal bone level changes with time showed statistically significant difference between immediately loading group and delayed loading group (P<0.001). 3. ISQ value changes with time did not show statistically significant difference between immediately loading group and delayed loading group (P=0.079). ISQ value decreased with time in both groups, however, all implants showed stable ISQ value at 30 months-recall evaluation. 4. Marginal bone level changes with time did not show statistically significant differences among implantation sites (P=0.604). 5. ISQ value changes with time showed statistically significant differences among implantation sites (P=0.047). ISQ values of most posterior implants decreased with time comparing to other implants. Conclusion: Although the marginal bone level of the terminal abutment didn't different with the other implants, ISQ value of the terminal abutment was lower than that of the other implants. Therefore, further clinical evaluation would be needed in this point of view.

Comparison between denture wearer's evaluation and clinician's rating for complete denture (총의치 사용에 대한 환자와 술자간 평가 비교)

  • Byun, Jin-Soo;Huh, Yoon-Hyuk;Cho, Lee-La;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.364-369
    • /
    • 2016
  • Purpose: The aim of this study was to compare denture wearer's evaluation and clinician's technical rating for complete denture used on edentulous patients. Materials and methods: Total 43 edentulous patients who had complete denture fabricated more than one year ago were recalled. The questionnaire based on the various literatures was modified and applied to patients for subjective assessments. Functional aspects related to retention, stability, occlusion and denture condition were included in operator's evaluation. In addition, correlations were evaluated between patient's subjective and operator's objective assessments. Friedman test and Cohen's Kappa value were used for statistical analysis. Results: It was found that denture wearers' evaluations were slightly or fairly agree to clinician's rating for complete denture. More differences were found in maxillary denture than mandibular denture and moderate difference was found in esthetic, occlusion aspects. Conclusion: There were slightly or fairly agreement between subjective and objective evaluations.

Clinical evaluation of implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles (Locator attachment를 이용한 하악 임플란트 유지형 피개의치의 임상적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.283-290
    • /
    • 2011
  • Purpose: This study compared the marginal bone loss around dental implant that were placed in the canine areas of the mandibles and finded the survival rate of implants, marginal bone loss around implants and prosthetic complications in 10 patients treated with overdentures retained with Locator attachments. Materials and methods: Ten patients who had received implant retained overdentures in the mandibules using two implants and Locator attachments at Daegu Catholic University Medical Center from 2004 to 2010 were included in this study. Evaluations of the survival rate of implants, marginal bone loss and prosthetic complications were performed. Results: Implants placed in this study showed a 100% survival rate and the average annual bone loss was 1.03 mm ${\pm}$ 0.20 mm in the first year. The patients have verbally indicated that they are comfortable and that their overdentures function well. But, implant retained overdentures had various prosthetic complications such as male change, relining, rebasing and denture fracture. Conclusion: Implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.

Multilateral analysis of $Renova^{(R)}$ implant placement and its Survival rate ($Renova^{(R)}$ 임플란트 식립 후 단기간의 생존율에 대한 다각적 분석)

  • Yang, Jin-Hyuk;Kim, Sung-Tae;Jung, Ui-Won;Nam, Woong;Jung, Young-Soo;Shim, June-Sung;Moon, Hong-Seok;Lee, Keun-Woo;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.413-428
    • /
    • 2008
  • Purpose: Given the predictability of dental implant procedure from the studies of successful osseointegration, implant dentistry is often the treatment of choice to replace missing teeth in edentulous patient instead of the fixed prosthesis or removable denture. The $Renova^{(R)}$ dental implant has a RBM(Resorbable Blast Media) surface, internal hex prosthetic connection and a tapered design. At this study gives the analysis of the implant and the short term survival rate of the implant. Material and Methods: In this study, a multilateral analysis was performed on the subjects undergoing placement with $Renova^{(R)}$ implant between August 2006 and February 2008 in Yonsei University dental hospital. 96 implants were placed in 56 patients and they were surveyed for cumulative survival rate. Among them 78 implants in 44 patients were surveyed for the rest analyses. Result: 1. The cumulative survival rate was 96.88% of 96 implants in 56 patients. 2. The mean marginal bone loss was 0.803mm and the marginal bone loss in augmentation group has higher value than the marginal bone loss in non augmentation group. 3. The health scale for the implants were 87% in success group, 9% in satisfactory survival group, 1% in compromised survival group, and 3% in failure group. 4. Two implants placed in poor bone posterior area by 2-stage failed during prosthetic procedure. Conclusion: $Renova^{(R)}$ dental implant showed high cumulative survival rate in installation on partial edentulous ridge and could be a predictable implant system.

Fabrication of suction denture by using the individual tray duplicated an existing denture through scan and milling process: A case report (스캔 및 밀링을 통해 기존 의치를 복제한 개인트레이를 이용한 흡착식 의치 제작 증례)

  • Park, Minhyuk;Kee, Wonjin;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug;Park, Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.221-227
    • /
    • 2020
  • In the case of complete edentulous patients, as the mandibular alveolar bone absorption progresses, the maintenance and stability of the existing dentures, which had satisfactory functions in the past, are deteriorated. Despite of the need to fabricate new dentures, they often hesitate due to physical burdens on the duration and intensity of future treatment progress due to the effects of aging and systemic diseases. In the case of these completely edentulous patients, it is necessary to consider the treatment goals that can reduce the number of visits and the adaptation period for new dentures before starting the treatment. This case is a case of producing complete dentures of elderly patients with deteriorated physical ability. In addition to producing suction dentures through preliminary and definitive closed mouth functional impression suggested by Sato, CAD / CAM technique was used to transfer occlusal functional information of existing dentures to facilitate adaptation to new dentures.

Evaluation of functional suitable digital complete denture system based on 3D printing technology

  • Deng, Kehui;Chen, Hu;Wang, Yong;Zhou, Yongsheng;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.361-372
    • /
    • 2021
  • PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

Complete denture of a skeletal class III patient with occlusal scheme in consideration: A case report (심한 골격성 class III 환자에서 교합양식을 고려한 총의치 수복증례)

  • Lim, Soeun;Kwon, Kung-Rock;Noh, Kwantae;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.50-55
    • /
    • 2018
  • Occlusal disharmony is frequently observed among edentulous patients. When artificial teeth come into contact, the unfavorable displacing force may lead to the discomfort, mucosal trauma, or even neuromuscular alterations and emotional disturbances. An optimal occlusal scheme is a critical factor for successful complete dentures. For this case, an edentulous patient with significant interarch size discrepancy due to mandibular prognathism contributing to inadequate function of dentures was treated with complete dentures. The posterior cross-bite tooth setup for compensating the abnormal jaw relations provided a stable and retentive complete denture prosthesis, which was considered adequate by both patient and dentist.

Comparative observations of lingualized occlusion and monoplane occlusion in the treatment of severe atrophy of edentulous mandible (심한 하악 치조골 흡수를 보이는 환자에서 설측 교두 교합과 단일평면 교합을 비교 관찰한 의치 수복 증례)

  • Ahn, Gyo-zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.127-136
    • /
    • 2018
  • The patient who has severely absorbed residual ridges, treatments are challenging to satisfy many factors: support, retention, stability, etc. The neutral zone or monoplane occlusion with non-anatomical tooth would be helpful to get additional retention and stability. The monoplane occlusion has been used long time because it can eliminate horizontal forces and many other advantages. The lingualized occlusion was introduced to improve chewing efficiency and esthetics. But from a stability aspect, it seems controversy between monoplane occlusion and lingualized occlusion. This case report shows the results of the treat two flat residual ridge patients using functional impression; piezography, and made 2 other dentures with monoplane and lingualized occlusion that patient can select denture.