• Title/Summary/Keyword: EWMA chart

Search Result 91, Processing Time 0.025 seconds

A Study of Demerit-DEWMA Control Chart (Demerit-DEWMA 관리도)

  • Kang, Hae-Woon;Baik, Jae-Won;Kang, Chang-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.2
    • /
    • pp.9-17
    • /
    • 2010
  • Complex products may present more than one type of defects and these defects are not always of equal severity. These defects are classified according to their seriousness and effect on product quality and performance. So, demerit systems are very effective systems to monitor the different types of defects. Recently, Kang et al.(2009) proposed the revised Demerit-CUSUM for the evaluation of the Demerit-CUSUM control chart performance exactly. In this paper, we present an advanced Demerit control chart using the double EWMA technique. The double EWMA technique is very efficient and strong method for process control where defects and nonconformities occur with various defect types. Moreover, we compare exact performance of Demerit-CUSUM, Demerit-EWMA and Demerit-DEWMA control chart according to changing sample size or mean shifts magnitude. By the result, we confirm that the performance of Demerit-DEWMA control chart is more than the performance of the Demerit-CUSUM and Demerit-EWMA control chart.

A Study on Optimum Value of Design Parameter of Multivariate EWMA and CUSUM charts for Monitoring Dispersion Matrix

  • Chang, Duk-Joon
    • Journal of Integrative Natural Science
    • /
    • v.14 no.3
    • /
    • pp.116-122
    • /
    • 2021
  • Properties and comparison of multivariate CUSUM and EWMA charts for monitoring Σ of multivariate normal N(${\underline{\mu}}$, Σ) process has considered. Comparison of the performances of the considered charts, the numerical values are obtained by simulation with 10,000 iteration in terms of ATS, ANSS and ANSW. We found that EWMA chart with small values of smoothing constant more effectively detects the process changes than with large smoothing constant. And we also found that CUSUM chart with small value of reference value is more effectively detecting the process change than with large reference value. If a process engineer has interest in detecting small amount of shift rather than large shift, he/she can be recommended to use small smoothing constant in EWMA chart and small reference value in CUSUM chart.

An Economic Design of the EWMA Control Charts with Variable Sampling Interval (VSI EWIMA 관리도의 경제적 설계)

  • 송서일;정혜진
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.4
    • /
    • pp.1-14
    • /
    • 2002
  • Traditional SPC techniques are looking out variation of process by fixed sampling interval and fixed sample size about every hour, the process of in-control or out-of-control couldn't be detected actually when the sample points are plotted near control limits, and it takes no notice of expense concerned with such sample points. In this paper, to overcome that, consider VSI(variable sampling interval) EWMA control charts which VSI method is applied. The VSI control charts use a short sampling internal if previous sample points are plotted near control limits, then the process has high probability of out-of-control. But it uses a long sampling interval if they are plotted near centerline of the control chart, since process has high possibility of in-control. And then a comparison and analysis between FSI(fixed sampling interval) and VSI EWMA in the statistical aspect and economic aspect is studied. Finally, we show that VSI EWMA control chart is more efficient than FSI EWMA control chart in the both aspects.

Control Charts for Constant Failure Rate of System

  • Cho, Gyo-Young;Lee, Ok-Hee
    • Journal of the Korean Data and Information Science Society
    • /
    • v.13 no.2
    • /
    • pp.147-156
    • /
    • 2002
  • In this paper, we propose EWMA control charts using the life time data for the system with the constant failure rate, which were drawn from the fixed sampling interval without replacement(with replacement), and investigate the power of detection of EWMA by comparing ARL of EWMA control charts with one of Shewhart control charts.

  • PDF

Control Charts for Constant Failure Rate of System

  • Cho, Gyo-Young;Lee, Ok-Hee
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.141-149
    • /
    • 2002
  • In this paper, we propose EWMA control charts using the life time data for the system with the constant failure rate, which were drawn from the fixed sampling interval without replacement (with replacement), and investigate the power of detection of EWMA by comparing ARL of EWMA control charts with one of Shewhart control charts.

  • PDF

EWMA chart Application using the Transformation of the Exponential with Individual Observations (개별 관측치에서 지수변환을 이용한 EWMA 관리도 적용기법)

  • 지선수
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.52
    • /
    • pp.337-345
    • /
    • 1999
  • The long-tailed, positively skewed exponential distribution can be made into an almost symmetric distribution by taking the exponent of the data. In these situations, to use the traditional shewhart control limits on an individuals chart would be impractical and inconvenient. The transformed data, approximately bell-shaped, can be plotted conveniently on the individuals chart and exponentially weighted moving average chart. In this paper, using modifying statistics with transformed exponential of the data, we give a method for constructing control charts. Selecting method of exponent for individual chart is evaluated. And consider that smaller weight being assigned to the older data as time process and properties and taking method of exponent($\theta$), weighting factor($\alpha$) are suggested. Our recommendation, on the basis result of simulation, is practical method for EWMA chart.

  • PDF

Performances of VSI Multivariate Control Charts with Accumulate-Combine Approach

  • Chang, Duk-Joon;Heo, Sun-Yeong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.3
    • /
    • pp.973-982
    • /
    • 2006
  • Performances of variable sampling interval(VSI) multivariate control charts with accumulate-combine approach for monitoring mean vector of p related quality variables were investigated. Shewhart control chart is also proposed to compare the performances of CUSUM and EWMA charts. Numerical comparisons show that performances of CUSUM and EWMA charts are more efficient than Shewhart chart for small or moderate shifts, and VSI chart is more efficient than fixed sampling interval(FSI) chart. We also found that performances of the CUSUM or EWMA chart with accumulate-combine approach are substantially efficient than those of Shewhart chart.

  • PDF

Multivariate EWMA Control Chart for Means of Multiple Quality Variableswith Two Sampling Intervals

  • Chang, Duk-Joon;Heo, Sunyeong
    • Journal of Integrative Natural Science
    • /
    • v.5 no.3
    • /
    • pp.151-156
    • /
    • 2012
  • Because of the equivalence between control chart procedures and hypothesis testing, we propose to use likelihood ratio test (LRT) statistic $Z_i^2$ as the multivariate control statistic for simultaneous monitoring means of the multivariate normal process. Properties and comparisons of the proposed control charts are explored and conducted for matched fixed sampling interval (FSI) and variable sampling interval (VSI) with two sampling interval charts. The result of numerical comparisons shows that EWMA chart with two sampling interval procedure is more efficient than the corresponding FSI chart for small or moderate changes. When large shift of the process has occurred, we also found that Shewhart chart is more efficient than EWMA chart.

-Performance Evaluation of $\bar{x}$ and EWMA Control Charts for Time series Model using Bootstrap Technique- (시계열 모형에서 붓스트랩 기법을 이용한 $\bar{x}$ 와 EWMA 관리도의 수행도 평가)

  • 송서일;손한덕
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.57
    • /
    • pp.123-129
    • /
    • 2000
  • The Bootstrap method proposed by Efron is non-parametric method which doesn't depend on the estimation of prior distribution refer to population. A typical statistical process control chart which is generally used is developed under the assumption that observations follow mutually independent and identically distributed within a sample and between samples. However, autocorrelation greatly affect the developed control chart under the assumption that observations are mutually independent. Many researchers showed that the result which was analyzed by using a typical control chart for the observations which has the correlation violated to the independence assumption can not be true. Therefore, we compared the standard method with bootstrap method and then evaluated them for x control chart and EWMA control chart by using bootstrap method which was proposed by Efron in the AR(1) model when the observations have correlation.

  • PDF

Comparisons of Multivariate Quality Control Charts by the Use of Various Correlation Structures

  • Choi, Sung-Woon;Lee, Sang-Hoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.20 no.3
    • /
    • pp.123-146
    • /
    • 1995
  • Several quality control schemes have been extensively compared using multivariate normal data sets simulated with various correlation structures. They include multiple univariate CUSUM charts, multivariate EWMA charts, multivariate CUSUM charts and Shewhart T$^{3}$ chart. This paper considers a new approach of the multivariate EWMA chart, in which the smoothing matrix has full elements instead of only diagonal elements. Performance of the schemes is measured by avaerage run length (ARL), coefficient of variation of run length (CVRL) and rank in order of signaling of off-target shifts in the process mean vector. The schemes are also compared by noncentrality parameter. The multiple univariate CUSUM charts are generally affected by the correlation structure. The multivariate EWMA charts provide better ARL performance. Especially, the new EWMA chart shows remarkable results in small shifts.

  • PDF