• Title/Summary/Keyword: EQUIPMENT PERFORMANCE

Search Result 3,531, Processing Time 0.033 seconds

The Study for maintence of heavy duty Agitator (대형교반기의 유지 관리에 관한 연구)

  • Kang, M.H.;Yang, S.B.;Kim, K.P.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.425-430
    • /
    • 2005
  • This Study presents to be Agitator maintenance for Water and Wastewater treatment Plant. This procedures offers methods of Design Creteria and performance tests on mixing equipment. These tests may be conducted to determine process performance, mechanical reliability. or suitability of equipment for the intended use. The reasons for conducting performance tests can be varied, but the methods presented should be generally applicable to most situations.

  • PDF

A Study on the Performance Certification System of Inspection and Diagnostic Equipment for Infrastructure using Advanced Technologies (첨단기술을 이용한 시설물 점검 및 진단장비 성능인증체계에 대한 연구)

  • Hong, Sung-Ho;Kim, Jung-Gon;Cho, Jae-Young;Kim, Do-Hyoung;Kim, Jung-Yeol;Kim, Young-Min;Lee, Dong-Wook
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.97-111
    • /
    • 2021
  • Purpose: It is expected that various infrastructures diagnosis equipment will be needed as infrastructures management is strengthened to implement the Framework Act on Sustainable Infrastructure Management. It is necessary for a certification system to supply certified products of a reasonable level in accordance with market requirements for various convergence equipment. This paper deals with the introduction of certification system of inspection and diagnosis equipment for infrastructure using advanced technologies. Method: The basic elements, systems and procedures of certification system were reviewed through analyzing and comparing the existing similar certification system in Korea. In addition, a survey was conducted on a catalog method and the minimum performance criterion (sampling survey and complete enumeration survey) to equipment developers (manufacturers), clients and equipment users. Result: This survey showed that clients preferred complete enumeration method on the basis of minimum performance, and equipment users also preferred complete enumeration survey and sample survey, for minimum performance, at a similar rate. On the other hand, equipment developers preferred the catalog method. Conclusion: Clients and users who are the users of the diagnostic equipment preferred the minimum performance criterion because their trust in quality is important. On the other hand, developers(manufacturers) preferred the catalog method which adopts self certification because it is regulated in developing various products. There is no specific plan for the minimum performance standards required for the introduction of the method which users demand, at present. In addition, it is not desirable to force to introduce a certification system because it requires a considerable period of study to prepare the specific standards. Therefore, it is appropriate to operate the system for a certain period of time centering around the catalog method for the stable and continuous development of the infrastructure diagnosis and test equipment market in Korea. Also, it is effective to expand and develop the certification system to the extent that it minimizes the impact on the market when specific plans for the standards are prepared in the future.

Developing Aged-Housing Remodeling Technology for Improving Structural and Equipment Performance;Introduction of Center for Aged-housing Remodeling Technology (노후 공동주택 구조 및 설비성능개선 기술 개발;연구단 소개)

  • Han, Ju-Yeoun;Cha, Hee-Sung
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.233-239
    • /
    • 2006
  • As the number of aged-housing has been rapidly increased, many kinds of defects and problems such as degeneration of housing environment, structural performance, and equipment performance have been appeared. The reconstruction as the way to improve the aged-housing has been used mostly because the legal process of the reconstruction is relatively easy. On the other hand, it has caused problems such as the lack of natural aggregate, the environmental damages owing to construction wastes, the loss of national resources, and the lack of the housing for rent nearby the reconstruction area. This problems limit active tying into the reconstruction business at present in the industrial and political perspective. In this context, it is required to revitalize the remodeling rather than the reconstruction. In order to reach this objective, this research aims at identifying the user-oriented performance for the housing industry and developing the new technologies. It is expected that the result of this research can contribute to more revitalize the remodeling as tying researches in terms of design, structure, equipment, and construction.

  • PDF

New Topology for Valve Performance Test Equipment of MMC based STATCOM (MMC 기반 STATCOM 용 밸브의 성능시험 장치를 위한 새로운 토폴로지)

  • Bae, Jongwoo;Jung, Jae-Hun;Nho, Eui-Cheol;Chung, Yong-Ho;Baek, Seung-Taek;Lee, Jin-Hee;Kim, Young-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • This study proposes a new topology for the performance test of a valve consisting of a modular multilevel converter (MMC)-based static synchronous compensator (STATCOM). The conventional valve performance test equipment requires high-voltage AC source of several kV rating because the number of submodules to be tested in a valve should be at least six or eight. However, the power source of the proposed scheme is DC and not AC source. The DC power source voltage range of the proposed test circuit is from several volts to several tens of volts. Therefore, the size and cost for the performance test equipment can be reduced considerably compared with the conventional method. The proposed scheme satisfies the requirements of the IEC 62927 standard. Simulations are conducted for a valve of 50[MVA] MMC-based STATCOM. Experimental results with a scale-downed setup show the validity of the proposed performance test topology.

The Effect of Work Performance to Smart Phone's Characteristics and Moderated Effects of Innovation Resistance (스마트폰의 특성이 개인의 업무성과에 미치는 영향과 혁신 저항성의 조절효과)

  • Kim, Kyung-Nam;Park, Ji-Hye;Chung, Do-Bum
    • The Journal of Information Systems
    • /
    • v.20 no.2
    • /
    • pp.57-80
    • /
    • 2011
  • This study analyzed the effects of smart phone using for business on work performance in the field. We classified functional and practical aspects of smart phone affecting employee's work performance through former studies. As independent variables, we selected portability of equipment, rapidity of information and ease of use for functional side, and selected fit to work and subjective norms for practical side. And dependent variable was work performance. We also suggested that innovation resistance would be a moderator. The results showed that the effect of work performance was influenced by portability of equipment and fit to work. However, hypotheses on moderating effects of innovation resistance were not supported. This study made a discrimination in terms of an application phase of smart phone as against former studies. The results of this study will provide practical implications for related enterprises in the field to develop ways of using smart phone as an effective strategy.

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash (수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰)

  • Lee, Kiyeon;Gil, Hyoungjun;Kim, Dongook;Kim, Dongwoo;Kang, Daechul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

Construction Equipment Fleet Optimization for Saving Fuel Consumption (에너지 절감을 위한 건설장비 조합 최적화 방법 연구)

  • Yi, Chang-Yong;Lee, Hong-Chul;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.198-199
    • /
    • 2015
  • Construction equipment is a major energy consumption source in construction projects. If 10% reduction of the diesel fuel usage is achieved in the construction industry, it may reduce 5% of the total energy usage. Energy saving operation is a major issue in equipment-intensive operations (e.g., earthmoving or paving operations). Identifying optimal equipment fleet is important measure to achieve low-energy consumption in those operations. This study presents a system which finds an optimal equipment fleet by computing the low-energy performance of earthmoving operations. It establishes construction operation model and compares numerous combinations using alternative equipment allocation plans. It implements sensitivity analysis that facilitates searching the lowest energy consumption equipment fleet by enumerating all cases.

  • PDF

Case Study of Short Animation with Facial Capture Technology Using Mobile

  • Jie, Gu;Hwang, Juwon;Choi, Chulyoung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.3
    • /
    • pp.56-63
    • /
    • 2020
  • The Avengers film produced by Marvel Comics shows visual effects that were impossible to produce in the past. Companies that produce film special effects were initially equipped with large personnel and equipment, but technology is gradually evolving to be feasible for smaller companies that do not have high-priced equipment and a large workforce. The development of hardware and software is becoming increasingly available to the general public as well as to experts. Equipment and software which were difficult for individuals to purchase before quickly popularized high-performance computers as the game industry developed. The development of the cloud has been the driving force behind software costs. As augmented reality (AR) performance of mobile devices improves, advanced technologies such as motion tracking and face recognition technology are no longer implemented by expensive equipment. Under these circumstances, after implementing mobile-based facial capture technology in animation projects, we have identified the pros and the cons and suggest better solutions to improve the problem.

A Study of Development and Improvement for Butterfly Valve Performance & Life Test Equipment (버터플라이밸브 성능 및 수명시험장치 개발과 개선에 관한 연구)

  • Lee, Gi-Chun;Kim, Hyoung-Eui;Jung, Dong-Soo;Kim, Jae-Hoom
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.51-56
    • /
    • 2012
  • The butterfly valve has been used over all industries. It has been studied to improve its performance through the theoretical analysis and the test in industry. Though products adopted those improvements have been sold in markets, manufacturers often launch products without the life test. One reason is because of the long development period and financial difficulties. The other is the lack of the design and fabrication experiences on building the life test equipment. Thus, this study has been researched for the design and fabrication of our life test equipment, and developed and improved the equipment to check the leakage of the valve with the naked eyes during the test.

A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant (수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구)

  • Byun, Doo-Gyoon;Chang, Moon-Soung;Kim, Ju-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF