• Title/Summary/Keyword: EMF Measurement

Search Result 80, Processing Time 0.026 seconds

Measurement of Ion Concentrations in Denitrifying Biofilm by Microelectro-sensor (미소전극 센서를 이용한 탈질 생물막내의 이온 농도측정)

  • Jang, Am;Lee, Ssang G.;Kim, S.M.;Kim, In S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1833-1841
    • /
    • 2000
  • Microelectrode probe was made and applied to the biofilm in the biological treatment process as the state-of-art technology in order to actually measure the biofilm thickness, ionic concentration gradient, and material transport, etc. instead of classical theoretical approach. The working microelectrode, one of the main components of microelectrode probe, was easily contaminated and broken when determining the differences in the ionic concentrations through the measurement of biofilm's EMF (electromotive force). As a demonstration, two microelectrode probes were constructed in our lab for the measurement of the pH and $NO_3{^-}$ concentration in denitrifying biofilm. The microelectrode probe through the inner biofilm ($350{\mu}m$ from the surface of biofilm) showed that the pH was increased from pH 8 in the bulk solution to pH 8.3, on the other hand, the $NO_3{^-}$ concentration was decreased from 30 fig N/L in the bulk solution to 4 fig N/L.

  • PDF

Continuous Measurement of Ammonium-nitrogen and Nitrate-nitrogen using a Ion-Selective Microelectrode (이온선택성 미소전극을 이용한 암모니아성 질소 및 질산성 질소의 연속 농도 측정)

  • Lim, Mi-Ji;Seon, Ji-Yun;Park, Jeung-Jin;Byun, Im-Gyu;Park, Tae-Joo;Lee, Tae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.718-724
    • /
    • 2008
  • The ion selective microelectrode (ISME) has been used for measuring the ion profile of DO, $NH_4{^+}-N$, $NO_2{^-}-N$ and $NO_3{^-}-N$ in biofilm. In this study we evaluated the detection limit and validity of ISME and applied ISME for the continuous measurement of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration in the modified Ludzack-Ettinger (MLE) process. Average detection limits of $NH_4{^+}-N$ and $NO_3{^-}-N$ ISME were $10^{-4.44}M$ and $10^{-4.62}M$, respectively. Since the ISME with $5{\sim}10{\mu}m$ of tip diameter showed a faster response time than that of $1{\sim}5{\mu}m$, the ISME with a tip diameter of $5{\sim}10{\mu}m$ was fabricated and used to make real-time ion detections. Direct monitoring of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentrations in the aerobic (2) tank causes the instability of the electromotive force (EMF) for the initial 5~8 hours and also causes remarkable error values of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration. This phenomenon is caused by aeration and mixing in the reactor. Thus, the measuring chamber was newly designed for the aerobic (2) tank and then the EMF of the ISME were stabilized in less than 1 hour. Errors of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration were decreased after stabilization of the EMF. The ISME analysis were well corresponded to the results of auto analyzer and ion chromatography. Consequently, the concentration of $NH_4{^+}-N$ and $NO_3{^-}-N$ could be continuously measured for 178 hours by the ISME.

Implementation of SAR Measurement System with Stationary Probes (Probe 고정형 SAR 측정 시스템)

  • Kim, Jeong-Ho;Gimm, Youn-Myoung
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.443-447
    • /
    • 2005
  • The SAR measurement system with stationary probes, presented in this paper, can calculate area SAR value based ell the measured 9 electric field data. By converting obtained area SAR to the volume SAR, the results can be acquired in a few seconds. The system can be very useful tool in the stages of handset development for mobile communication as well as in the handset production line because of its rapid SAR measurement. The system showed good linearity characteristics at 835 MHz of 10 $\sim$ 27 dBm input power range.

  • PDF

Design and Thrust Force Measurement of LSM for High-Speed Maglev Train (초고속 자기부상열차용 LSM 설계 및 추력 측정 시험)

  • Oh, Se-Young;Lee, Chang-Young;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1473-1478
    • /
    • 2014
  • This paper deals with design and thrust force measurement of EMS type LSM for propulsion of the high-speed maglev train. The load of maglev train is calculated, and the design equations of the LSM are presented, and the LSM which is suitable for the operation of short-distance test track is designed. In addition, the finite element analysis is performed to confirm the back-EMF and thrust force characteristics of the LSM designed model. A short length LSM prototype model is manufactured. Finally, the thrust force of the LSM is measured by the method applying dc current to the stator winding instead of three-phase ac current. And the validity of the design and analysis is verified by this measurement.

Standard Trends of Human Exposure to Electromagnetic Waves (전자파 인체 노출 표준 동향)

  • Jeon, S.B.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.3
    • /
    • pp.86-92
    • /
    • 2019
  • New products and services, such as 5G and wireless power transmission equipment, have recently brought about changes in the field of electromagnetic technology. There is a need for the evaluation and measurement of the health effects of such technology. To address this need, the development of international standards related to human exposure to electromagnetic waves of these new technologies are currently being discussed. This article briefly introduces the International Standard Organization standards for human exposure to electromagnetic waves, and focuses on the major standard trends for SAR measurement techniques that employ vector probes, wireless power transfer, and 5G base station measurement.

Remote Measurement System for Human Exposure to EMF based on Communication Network (통신망 기반의 전자파 인체노출 원격측정시스템)

  • Cho, Kwanh-Yun;Yoon, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.384-385
    • /
    • 2008
  • 본 논문은 전력선이나 무선기지국 처에서 방축된 전자파를 인터넷, 휴대폰 등 통신수단을 이용하여 원격지에서 실시간으로 측정, 감시할 수 있도록 고안된 전자파 인체노출 원격측정 시스템에 대하여 기술한다. 본 시스템은 측정 자동화 및 무인차 개념이 도입되었으며, 국제규격에서 권고한 측정프로토콜에 따라 측정수행이 되므로 전자파인체노출기준의 적합성 여부론 판단하는 표준측정 시스템으로도 활용될 수 있다.

  • PDF

Managing Technological Risk and Risk Conflict : Public Debates on Health Risks of Mobile Phones EMF (기술위험 관리와 위험갈등 : 휴대전화 전자파의 인체유해성 논란)

  • Jung, Byung-Kul
    • Journal of Science and Technology Studies
    • /
    • v.8 no.1
    • /
    • pp.97-129
    • /
    • 2008
  • We are living in the time of high probability of technological risk due to increased rate of technology development and diffusion of new technologies. Resolving uncertainties, the basic attribution of risk, by accumulating knowledge over the risk factors of certain technology is critical to management of technological risk. In many cases of technological risks, high uncertainty of knowledge is commonly mentioned reason for public controversies on risk management. However, the type of technological risk with low social agreement and low uncertainty of knowledge, the main reason for public controversy is absence of social agreement. Public debates on the risks of mobile phones electromagnetic fields(EMF) to human health comes under this category. The knowledge uncertainty on human health effect of mobile phones EMF has been lowered increasingly by accumulating enormous volume of knowledge though scientists have not reached a final conclusion whether it pose a risk to the physical and mental health of the general population or not. In contrast with civil organizations calling for precautionary approach based regulation, the mobile phone industry is cling to the position of no-regulation-needed by arguing no clear evidence to prove health risks of mobile phone EMF has found. In Korea, government set exposure standards based on a measurement called the 'specific absorption rate'(SAR) and require the mobile phone industry to open SAR information to the public by their own decision. From the view of pro-regulation side based on precautionary approach, technology risk managament of mobile phones EMF in Korea is highly limited and formalized one with limited measuring of SAR on head part only and problematic self-regulated opening of information about SAR to the public. As far as the government keeps having priority on protecting interest of mobile phone industry over precautionary regulation of mobile phones EMF, the disagreement between civil organizations and the government will not resolved. The risk of mobile phones EMF to human health have high probability of being underestimated in the rate and damage of risk than objectively estimated ones due to familiarity of mobile phone technology. And this can be the cause of destructive social dispute or devastating disaster. To prevent such disastrous results, technology risk management, which integrating the goals of safety with economic growth in public policy and designing and promoting risk communication, is required.

  • PDF

Measurement of partial discharge point in power transformer using crosscorrelation (상호상관을 이용한 변압기내의 부분방전 위치측정)

  • 문영재;구춘근;정찬수;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.6
    • /
    • pp.34-41
    • /
    • 1993
  • This paper describes an effort to develop a microcomputer-based parameter identification system for three phase and two phase brushless DC motor. Back EMF equation is derived from back EMF waveform of three phase and two phase brushless DC motor. In this paper, a new identification algorithm for the brushless DC motor parameters by Pasek's technique is de veloped. It is found that Pasek's equation is valid for the brushless DC motor, too. The results obtained clearly shows that it is possible to implement the identification system for the determination of the brushless DC motor parameters. To minimize errors due to the ripple component in the measured armature current, dlgital averaging filter is employed. The whole identification process of signal generation, measuring, parameter determination is fully automated. The use of the pmpased method in the parameter identification system shows that the averaged current curve is in excellent agreement with the estimated current curve. Therefore, this close agreement conf i i the validity of this technique.

  • PDF

Electromagnetic Forces Measurement of Various Electric Appliances and Places (각종 전기기기 및 장소에서의 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Kim, Su-Chan;Yoon, Hyung-Ro
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.179-182
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces(EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, once machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven senates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

A Design of Programmable Low Pass Filter to Reduce the ZCP Estimation Error at High Speed BLDC Sensorless Drive (BLDC 고속 센서리스 구동의 ZCP 추정 오차 저감을 위한 Programmable Low Pass Filter 설계)

  • Seo, Eunjeong;Lee, Kangseok;Lee, Wootaik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • This paper presents a design method of programmable low pass filter(PLPF) which reduce an estimation error of a zero crossing point(ZCP) for a high speed brushless DC(BLDC) motor drive. BLDC motor sensorless drive is possible by estimation of ZCP. The ZCP estimated by detecting a change of back-EMF polarity has the estimation error because noises exist on the measured back-EMF. Therefore a calculated commutation timing using the ZCP is inaccurate. And the inexact commutation timing leads to ripples of 3-phase current and degradation of drive performance. This paper proposes the design method of the PLPF to overcome these problems. First, a speed calculated a inaccurate period of the ZCP is analyzed in the frequency domain. Then, the PLPF that has varying cut-off frequency according to change of the speed is designed on the frequency analysis result. The proposed method is verified by the experiment.