• Title/Summary/Keyword: EI-GC/MS/MS

Search Result 31, Processing Time 0.024 seconds

Determination of N-nitrosamines in Water by Gas Chromatography Coupled with Electron Impact Ionization Tandem Mass Spectrometry (EI-GC/MS/MS를 이용한 니트로사민류의 수질분석)

  • Lee, Ki-Chang;Park, Jae-Hyung;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.764-770
    • /
    • 2014
  • This study assessed analysis of N-nitrosamines by separation, identification, and quantification using a gas chromatography (GC) mass spectrometer (MS) with electron impact (EI) mode. Samples were pretreated by a automated solid phase extraction (SPE) and a nitrogen concentration technique to detect low concentration ranges. The analysis results by EI-GC/MS (SIM) and EI-GC/MS/MS (MRM) on standard samples with no pretreatment exhibited similar results. On the other hand, the analysis of pretreated samples at low concentrations (i.e. ng/L levels) were not reliable with a EI-GC/MS due to the interferences from impurity peaks. The method detection limits of eight (8) N-nitrosamines by EI-GC/MS/MS analysis ranged from 0.76 to 2.09 ng/L, and the limits of quantification ranged from 2.41 to 6.65 ng/L. The precision and accuracy of the method were evaluated using spiked samples at concentrations of 10, 20 and 100 ng/L. The precision were 1.2~13.6%, and the accuracy were 80.4~121.8%. The $R^2$ of the calibration curves were greater than 0.999. The recovery rates for various environmental samples were evaluated with a surrogate material (NDPA-$d_{14}$) and ranged 86.2~122.3%. Thus, this method can be used to determine low (ng/L) levels of N-nitrosamines in water samples.

Gas Chromatography-High Resolution Tandem Mass Spectrometry Using a GC-APPI-LIT Orbitrap for Complex Volatile Compounds Analysis

  • Lee, Young-Jin;Smith, Erica A.;Jun, Ji-Hyun
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.29-38
    • /
    • 2012
  • A new approach of volatile compounds analysis is proposed using a linear ion trap Orbitrap mass spectrometer coupled with gas chromatography through an atmospheric pressure photoionization interface. In the proposed GC-HRMS/MS approach, direct chemical composition analysis is made for the precursor ions in high resolution MS spectra and the structural identifications were made through the database search of high quality MS/MS spectra. Successful analysis of a complex perfume sample was demonstrated and compared with GC-EI-Q and GC-EI-TOF. The current approach is complementary to conventional GC-EI-MS analysis and can identify low abundance co-eluting compounds. Toluene co-sprayed as a dopant through API probe significantly enhanced ionization of certain compounds and reduced oxidation during the ionization.

Investigation of N-nitrosamines using GC-MS/MS in Han-river Water Supply Systems (GC-MS/MS를 이용한 한강수계 및 상수도계통에서 N-nitrosamines 조사)

  • Yoon, Woo-hyun;Lee, Jun-ho;Lee, Hyun-ju;Lee, Su-won;Ahn, Jae-chan;Kim, Bog-soon
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.5
    • /
    • pp.410-418
    • /
    • 2016
  • This study was conducted to improve the analysis method used for N-nitrosamines and to investigate the occurrences of N-nitrosamines in tributaries of the Han-river, intake stations, water treatment plants and tap water used within the city of Seoul. The samples were pretreated through a solid phase extraction and analyzed using a gas chromatography tandem mass spectrometer (GC-MS/MS). The GC-MS/MS in CI mode was compared with the GC-MS/MS in EI mode by the method detection limits (MDLs). MDLs by GC-CI/MS/MS and GC-EI/MS/MS were 0.2 ~ 1.1 ng/L and 0.2 ~ 1.4 ng/L, respectively. Samples were collected from ten tributaries of the Han-river (T1 ~ T10), six intake stations (I1 ~ I6), six water treatment plants (P1 ~ P6) and 25 taps in Seoul city. The maximum levels of N-nitrosodimethylamine (NDMA) were 0.013 μg/L, 0.008 μg/L, 0.006 μg/L and 0.002 μg/L in tributary water, raw water, finished water and tap water samples, respectively. Detected levels were much lower than 0.1 μg/L corresponding to the guideline value of WHO.

Quantitative Analysis of amphetamines in hair by EI-GC-MS using SIM mode with uncertainty estimation

  • Yang, Won-Kyung;Han, Eun-Young;Lee, Jae-Sin;Park, Yong-Hoon;Kim, Eun-Mi;Lim, Mi-Ae;Chung, Hee-Sun
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.169.2-169.2
    • /
    • 2003
  • A method using EI-GC-MS is described for the determination of amphetamines in hair. The method is applied to simultaneous quantify amphetamines (methamphetamine, amphetamine, MDMA and MDA). Drugs were extracted in 1 % HCl in methanol from hair. After derivertization with TFAA, the resulting drugs were separated on HP-5MS column during a 16 min program and identified by mass spectrometry with the SIM mode(EI-GC-MS). (omitted)

  • PDF

Analysis of derivatized MX by Gas Chromatography/Mass Spectrometry (GC/MS를 이용한 MX 유도체화 분석법 연구)

  • Yoo, Eun-Ah;Park, Do-Yeon;Lee, Hyang-Ki;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.221-228
    • /
    • 2002
  • AMX is one of extremely high mutagenic compound produced from the reaction of the chlorine and the organic compound during the disinfection of tap water. In this paper, the chemical derivatization of MX with 2% sulfuric acid-methanol, iso-propanol, sec-butanol and n-butanol derivatives for the GC/MS analysis were tested or compared. Limit of detection for the EI and NCI mode were 25 pg and 1.25 pg, respectively. The good linear calibration curve was obtained the range of 25~2500 pg by EI and NCI

GC-MS/Ms Analysis of Benzo(a)pyrene by Ion Trap Tandem Mass Spectrometry

  • Nam, Jae-Jak;Lee, Sang-Hak
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.8
    • /
    • pp.1097-1102
    • /
    • 2002
  • The mass spectrometry using an ion trap tandem mass spectrometer has been investigated to find optimum conditions for the analysis of benzo(a)pyrene (3,4-benzpyrene). The applicability to a real soil sample was also investigated to verify the usef ulness of the MS/MS (or collision induced dissociation, CID) analysis. The optimum CID condition was 1.5 and 0.45 for the RF excitation voltage and the q value, respectively. For comparison, CID and EI were applied to the analysis of a soil sample. CID analysis was more sensitive than EI analysis of the soil sample. The limit of detection (LOD) of benzo(a)pyrene was 3.18 ng mL-1 and 0.85 ng mL,-1 for EI and MS/MS analysis, respectively. The precision at the soil sample for EI and CID showed relative standard deviations of 6.1% and 4.1%, respectively, and the concentrations were 168 ㎍ kg-1 and 162 ㎍ kg-1 , respectively.

Analysis of Residual Pesticides in Herbal Drugs: GC/MS Analysis of 27 Controlled Pesticides (생약 중 잔류 농약의 분석법: GC/MS에 의한 27종 잔류 규제 농약의 분석)

  • Park, Man-Ki;Park, Jeong-Hill;Yoon, Hye-Ran;Yoon, In-Byoung;Cho, Sool-Yeon;Hwang, Gwi-Seo
    • YAKHAK HOEJI
    • /
    • v.40 no.2
    • /
    • pp.141-148
    • /
    • 1996
  • GC/MS analysis of 27 controlled pesticides in herbal drugs was studied. Selected ion monitoring(sim) technique was applied to increase the GC/MS sensitivity. Typical peaks in th e mass spectrum of each pesticides were selected as quantitation, comfirmation or alternate ion. Twenty seven pesticides were divided into five groups according to their retention time and the peaks for SIM were programmed accordingly. The combination of two ionization methods, electron impact(EI)-SIM-MS and negative ion chemical ionization(NCI)-SIM-MS, were well-fitted for the detection, confirmation and quantitation of multiclass residual pesticides in herbal drugs.

  • PDF

Determination of the PDE-5 Inhibitors and Their Analogues by GC-MS and TMS Derivatization

  • Pyo, Jae-Sung;Lee, Hee-Sang;Park, Yu-Jin;Jo, Ji-Yeong;Park, Yong-Hoon;Choe, Sang-Gil;Lee, Mi-Young;Lee, Jae-Sin
    • Mass Spectrometry Letters
    • /
    • v.3 no.1
    • /
    • pp.15-17
    • /
    • 2012
  • Eighteen of the PDE-5 inhibitors and their analogues were analyzed using GC-EI-MS. Fourteen of them could be identified by simple GC-MS method without derivatization, but hydroxyhongdenafil, hydroxyvardenafil, xanthoanthrafil and mirodenafil could not be identified without derivatization for the high polarity due to the presence of hydroxyl groups. N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), widely used trimethylsilyl (TMS) derivatizing reagents, were used to improve the sensitivity of the hydroxylated analogues. And the analytes could be identified by GC-MS after the derivatization.

Development of Rapid Analysis Method for Pesticide Residues by GC-MS/MS (GC-MS/MS를 이용한 잔류농약 신속검사법 개발)

  • Choi, Yong-Hoon;Nam, Hye-Seon;Hong, Hye-Mi;Lee, Jin-Ha;Chae, Kab-Ryong;Lee, Jong-Ok;Kim, Hee-Yun;Yoon, Sang-Hyeon
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.292-302
    • /
    • 2005
  • Condition of Ion-Trap gas chromatography-mass spectrometry (GC-MS) for rapid screening of 206-pesticides residues in agricultural foodstuffs was optimized. As applying a wide-bore column (10 m${\times}$0.53 mm, DF 0.25 um) connected with a fused silica restrictor (0.6 m${\times}$0.1 mm), a significant retention time reduction was obtained. Additionally, the shape of peaks was sharper and higher than classical GC's and GC-MS's, which allowed lower detection limits. To easily manage many spectral data, both of Electron Ionization(EI) and Chemical Ionization(CI) techniques were adopted in screening procedure. At the following steps, MS-MS technique were used to confirm screened analytes in complicated matrices.

The Stimultaneous Determination of Phenolic Compounds by GC and GC/MS

  • Kim, Jong-Bae;Park, Jyung-Rewng
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.2
    • /
    • pp.111-118
    • /
    • 1998
  • To develop a simple, rapid and simultaneous analytical method of phenolic compounds using gas chromatography (GC) and gas chromatography/mass spectrophometer (GC/Ms), this experiment was carried out to search the retention times of capillary columns and the characteristics of fragment ions in electron impact mass spectra. Most of trimethylsilyl derivatives and underivatized phenolic compounds were separated very well on three kinds of capillary columns(HP-1), Ultra-2 and HP-35). Quantitiative determination of phenolic compounds was achieved by internal standards (p-hydroxybenzoic acid iopropyl ester, p-hydroxybenzoic acid ethyl ester). Calibration plts were linear in the investigated range, and the limits of detection were about 5 ng at split mode method. When analyzed by three columns, theseparation times were fairly constant on two nonpolar columns, but a few compounds showed slightly different separation order by the itnermediate polar HP-35 column. The important characteristic patterns of TMS derivatives of phenolic compounds on the EI/MS spectrra appeared at the base peak of [M-15]+ ion and presented at high abundance in most TMS derivatives of phenoloc compounds. [M]+, [M-CH3-COO]+, [M-Si(CH3)4]+ and [M-Si(CH3)4 -CH3]+ also observed in mass spectra of these compounds . Although several compounds have the same retention times on GC column, it might be possible to identify these compounds by the different patternsof mass frgement ions. The TMS derivatives, thus , provide additional information for identification of phenolic compounds in biological systems.

  • PDF