• Title/Summary/Keyword: E-J characteristic

Search Result 177, Processing Time 0.026 seconds

A study on the characteristics of deterioration in 6.6kV CV cable (6.6kV CV케이블의 경년열화 특성연구)

  • Kim, K.H.;Sun, J.H.;Kim, Y.B.;Cho, Y.O.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.636-639
    • /
    • 1993
  • This paper is discribed the results of insulation characteristic tests that are DC leakage current, test, tan${\delta}$ test, AC breakdown test and observation of tree in the used 6.6kV CV cables. In the correlation of these tests, the tan${\delta}$ test stands for the main deterioration factor of cable insulation.

  • PDF

Comparison of vibration and noise of higher utility factor Insulation Panel for Transformer (변압기용 고효율 차음판의 진동 및 소음 비교)

  • Jeong, J.H.;Lee, J.H.;Jeong, H.E.;Lim, D.S.;Kim, J.;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.112-116
    • /
    • 2007
  • Highly damped insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in inner city is appeared a lost of problem by increasing to conserve living environment. Therefor in this paper, the vibration and noise characteristic effect of cork-type and sponge-type that is attached between insulation panel and enforce beam in transformer is analized using real size transformer experimentally.

  • PDF

Parallel Operation Control Technique of On-line UPS System (온라인 무정전전원장치의 병렬운전 제어기술)

  • Cho J.S.;Kang B.H.;Gho J.S.;Choe G.H.;Kim J.H.;Chung S.E.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

The analysis on the characteristic of the conductivity concrete materials (접지저항 저감제 성능분석)

  • Kang, Y.W.;Choi, J.K.;Kwak, J.S.;Joo, H.J.;Shim, E.B.;Bang, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.169-172
    • /
    • 2004
  • The tower footing resistance is an extremely important parameter in the determination of lightning flashover. For the reduction of back flashover faults, power utility companies have had a concern to decrease the footing resistance. There are two manufactures of the conductivity concrete materials in Korea. In this paper, we investigated possibility of soil pollution due to the conductivity concrete materials. Also, we analyzed on the reduction characteristics of footing resistance of those.

  • PDF

FREE AND NEARLY FREE CURVES FROM CONIC PENCILS

  • Dimca, Alexandru
    • Journal of the Korean Mathematical Society
    • /
    • v.55 no.3
    • /
    • pp.705-717
    • /
    • 2018
  • We construct some infinite series of free and nearly free curves using pencils of conics with a base locus of cardinality at most two. These curves have an interesting topology, e.g. a high degree Alexander polynomial that can be explicitly determined, a Milnor fiber homotopy equivalent to a bouquet of circles, or an irreducible translated component in the characteristic variety of their complement. Monodromy eigenspaces in the first cohomology group of the corresponding Milnor fibers are also described in terms of explicit differential forms.

Technology and Characteristic of Magnetic Bearing (자기 베어링의 기술 현황 및 특성)

  • Jang, S.M.;Kwon, J.K.;Cho, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1039-1041
    • /
    • 2003
  • There are many advantages of the Magnetic Bearing system, compared with conventional contacting bearing systems. Since the spindle in the Magnetic Bearing system is levitated by electro-magnetic forces and rotates without mechanical friction, it can run without lubrication. So, it can run in the extreme circumstances, e.g. a vacuum condition in the space.

  • PDF

Sealing analysis of sealing rings with respect to rubber material properties for high pressure valve of FCEV (FCEV용 고압 밸브 실링부의 고무재질에 따른 기밀해석)

  • Park, G.Y.;Yang, K.J.;Ro, E.D.;Park, J.S.;Chon, M.S.;Lee, H.W.
    • Journal of Institute of Convergence Technology
    • /
    • v.7 no.2
    • /
    • pp.13-16
    • /
    • 2017
  • The design of sealing mechanisms of a manual pressure valve was analyzed with FE analysis for a hydrogen fuels charge and discharge system of FCEV. The damage prediction of the O-ring with respect to the material models of rubbers was calculated by the gap analysis of the backup ring and O-ring according to the internal pressure. Two kinds of the rubber material characteristic models were adopted to the O-ring. One was the linear elastic and the other was hyperelastic of Ogden $3^{rd}$ order model. The experimental data of urethane of Shore hardness 90 was utilized to the curve fitting of hyperelastic properties. It was found that the contact pattern of the backup ring was different in two models and the sealing mechanism was better in the case of the hyperelastic characteristic model.