• 제목/요약/키워드: Dynamic field test

검색결과 556건 처리시간 0.025초

현장측정을 통한 자갈도상 궤도의 동적 거동 분석 (A Study on the Dynamic Behaviors of Ballast Track using Field Test)

  • 최정열;박균서;류중열;박정근;류경식;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.494-507
    • /
    • 2006
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

  • PDF

Development of the Hovering AUV test-bed and field test

  • Choi, Hyeung-Sik;Cho, Sohyung;Kim, Joon-Young
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제2권1호
    • /
    • pp.40-47
    • /
    • 2016
  • This paper describes the design and performance of a hovering AUV constructed at KMOU (Korea Maritime and Ocean University). Before the field test, we analyzed the dynamic performance of the AUV using a simulation program made by Matlab & Simulink. Also, a PID controller was designed to control the thrusters. Using 4 thrusters (2 vertical and 2 horizontal), the AUV could be controlled using dynamic motion with 4-DOF. A simulation and field test were conducted with way-point tracking, maintaining the desired depth. To perform way-point tracking, the AUV can be fine-tuned to the desired heading angle through the LOS (Line Of Sight) method. This paper shows the results of simulation and field tests.

동적혼성 모델을 이용한 난류채널의 온도장 해석 (On the Large Eddy Simulation of Temperature Field Using Dynamic Mixed Model in a Turbulent Channel)

  • 이건호;나양
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1255-1263
    • /
    • 2004
  • An a priori test has been conducted for the dynamic mixed model which was generalized for the prediction of passive scalar field in a turbulent channel flow The results from a priori tests indicated that dynamic mixed model is capable of predicting both subgrid-scale heat flux and dissipation rather accurately. The success is attributed to the explicitly calculated resolved term incorporated into the model. The actual test of the model in a LES a posteriori showed that dynamic mixed model is superior to the widely used dynamic Smagorinsky model in the prediction of temperature statistics.

폐기물 매립장에서 동다짐공법의 적용성에 관한 연구 (Applicability of Dynamic Compact Pilot Test on Waste Landfill)

  • 천병식;임병수;김명진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.418-425
    • /
    • 2000
  • In this study, the evaluation for utilization of waste landfill was performed by field test to use waste landfill as construction site(Nangido in Seoul). The site where dynamic compaction test was carried out was divided by 4 yards. Yard 1, 2 were not eliminated widening of cover soil and Yard 3, 4 were eliminated it. Dynamic Compaction Pilot Test was carried out by the 15ton heavy tamper with drop height of 20m in Yard 1, 3 and with drop height of 15m in Yard 2, 4 We evaluated the compaction ability, optimum compaction number and noiseㆍvibration through field test, monitoring. To make use of waste landfill as a construction site, The dynamic compaction method is suitable for using in waste landfill as a construction site among the ground improvement methods.

  • PDF

노상토의 지지력 평가를 위한 다짐평가기법의 상관성 분석 (Analysis of Correlation among Various Compaction Evaluation Methods for Estimating of the Bearing Capacity on Subgrades)

  • 이준용;정재형;최창호;김진영;진현우
    • 한국지반신소재학회논문집
    • /
    • 제14권4호
    • /
    • pp.45-58
    • /
    • 2015
  • 국내에서의 도로 하부지반의 품질 관리는 주로 하중 지지력을 확인하는 평판재하시험과 상대 다짐도를 구하기 위한 현장들밀도시험을 이용하고 있으나, 최근에는 현장 여건에 맞는 적합성과 경제성, 신속성 등을 고려한 동적 콘 관입 시험과 동평판재하시험 등의 이용이 증가하는 상황이다. 이에 본 연구에서는 이러한 여러 다짐평가기법간의 상관성을 분석하기 위하여 실제 도로공사현장 3개소에서 노상두께 20cm, 30cm, 40cm에 대한 평판재하시험, 현장들밀도시험, 동적 콘 관입시험, 동평판재하시험을 이용하여 노상토의 지지력을 평가하였다. 또한, 각각의 다짐평가기법간의 결과를 비교 분석하여, 향후 활용법에 대하여 살펴보았다.

지하철 자갈도상 케도의 충격계수 평가 (Evaluation of Impact Factor on Ballast Track in Subway using Field Test)

  • 강기동;박용걸;최정열
    • 한국철도학회논문집
    • /
    • 제9권6호
    • /
    • pp.784-791
    • /
    • 2006
  • This paper presents the test results to evaluate the healthiness of the ballast in subway. The test includes the dynamic load test in servicing Line the screen classification test of aggregates and the wear test. From the results, the aspect and the property of the ballast are evaluated. The dynamic load tests explain the relationship between the deterioration of the ballast and the fluctuation of loads. The assessment of impact factor based on the field test results in a good property of test blocks is proposed.

지하철 자갈도상 궤도의 충격계수 평가 (Evaluation of Impact Factor on Ballast Track in Subway using Field Test)

  • 박균서;손철수;윤종경;최정열;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.484-493
    • /
    • 2006
  • This paper is presented the test results to evaluate the healthiness of the ballast in subway. The test includes the dynamic load test in servicing Line the screen classification test of aggregates and the wear test. From the results, the aspect and the property of the ballast are evaluated. The dynamic load tests the relationship between the deterioration of the ballast and the fluctuation of loads. The assesexplain sment of impact factor based on the field test results in a good property of test blocks is proposed.

  • PDF

On the Large Eddy Simulation of Scalar Transport with Prandtl Number up to 10 Using Dynamic Mixed Model

  • Na Yang
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.913-923
    • /
    • 2005
  • The dynamic mixed model (DMM) combined with a box filter of Zang et. al. (1993) has been generalized for passive scalar transport and applied to large eddy simulation of turbulent channel flows with Prandtl number up to 10. Results from a priori test showed that DMM is capable of predicting both subgrid-scale (SGS) scalar flux and dissipation rather accurately for the Prandtl numbers considered. This would suggest that the favorable feature of DMM, originally developed for the velocity field, works equally well for scalar transport problem. The validity of the DMM has also been tested a posteriori. The results of the large eddy simulation showed that DMM is superior to the dynamic Smagorinsky model in the prediction of scalar field and the model performance of DMM depends to a lesser degree on the ratio of test to grid filter widths, unlike in the a priori test.

동적 콘관입시험기를 이용한 폐석회 혼합 도로노반 성토체의 현장 지지력 평가 (Bearing Capacity of Pavement Foundation by Waste Lime Material using the Dynamic Cone Pentrometer)

  • 김영석;홍승서;배규진
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.927-935
    • /
    • 2011
  • 노상층의 지지력을 평가하는 일반적인 방법의 하나로 현장 CBR(California Bearing Ratio) 시험이 널리 이용되고 있다. 그러나 현장 CBR은 시간과 비용이 많이 소모되어 포장층의 강도특성을 단시간에 파악하기에는 어려운 단점이 있다. 최근에는 보다 신속하고 경제적인 방법으로 동적 콘관입시험(Dynamic Cone Penetrometer, DCP)이 많이 이용되고 있다. 본 논문에서는 폐석회를 혼합한 현장모형 노상토에 대하여 현장 CBR 시험과 DCP 시험을 수행하여 현장 지지력을 평가하였으며, 현장 CBR 값과 DCP 지수에 대한 상관관계를 분석하였다. 사용한 폐석회는 인천의 화학공장에서 소다회($Na_2CO_3$)를 생산하는 공정에서 부수적으로 발생하는 부산물이며, 현장시험에서는 현장함수비, 현장밀도, 현장 CBR 시험, DCP 시험을 수행하였다. 시험결과로부터 폐석회 활용도로 노상층에 대한 DCP지수를 제안하였다.

돌풍하중완화 풍동시험을 위한 돌풍발생장치 설계 및 지상시험 (Design and Ground Test of Gust Generator for GLA Wind Tunnel Test)

  • 이상욱;김태욱;김성찬;황인희;하철근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.45-48
    • /
    • 2005
  • Tile gust generator was designed for generating the gust field in the wind tunnel test of the scaled flexible wing model for validating gust response alleviation system. The ground operation test was performed for estimating the dynamic performance of tile gust generator before installing it in the wind tunnel for gust field measurement. The ground test results showed that the gust generator has sufficient dynamic capability to simulate the sinusoidal and random motion of the gust generator wing and thus can be used in the wind tunnel test related to gust.

  • PDF