• 제목/요약/키워드: Dynamic Measurement

검색결과 1,882건 처리시간 0.027초

이동통신 사용자의 이력 자료를 고려한 동적 위치영역 관리 기법 (Dynamic Location Area Management Scheme Using the Historical Data of a Mobile User)

  • 이재석;장인갑;홍정완;이창훈
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2004년도 춘계공동학술대회 논문집
    • /
    • pp.119-126
    • /
    • 2004
  • Location management is very important issue in wireless communication system to trace mobile users' exact location. In this study, we propose a dynamic location area management scheme which determines the size of dynamic location area considering each user's characteristic. In determining the optimal location area size, we consider the measurement data as well as the historical data, which contains call arrival rate and average speed of each mobile user. In this mixture of data, the weight of historical data is derived by linear searching method which guarantees the minimal cost of location management. We also introduce the regularity index which can be calculated by using the autocorrelation of historical data itself. Statistical validation shows that the regularity index is the same as the weight of measurement data. As a result, the regularity index is utilized to incorporate the historical data into the measurement data. By applying the proposed scheme, the location management cost is shown to decrease. Numerical examples illustrate such an aspect of the proposed scheme.

  • PDF

이동통신 사용자의 이력자료를 고려한 동적 위치영역 관리기법 (Dynamic Location Area Management Scheme Using the Historical Data of a Mobile User)

  • 이재석;장인갑;홍정완;이창훈
    • 산업공학
    • /
    • 제18권4호
    • /
    • pp.382-389
    • /
    • 2005
  • Location management is very important issue in wireless communication system to trace mobile users' exact location. In this study, we propose a dynamic location area management scheme which determines the size of dynamic location area considering each user's characteristics. In determining the optimal location area size, we consider the measurement data as well as the historical data, which contains call arrival rate and average speed of each mobile user. In this mixture of data, the weight of historical data is derived by linear searching method which guarantees the minimal cost of location management. We also introduce the regularity index which can be calculated by using the autocorrelation of historical data itself. Statistical validation shows that the regularity index is the same as the weight of measurement data. As a result, the regularity index is utilized to incorporate the historical data into the measurement data. By applying the proposed scheme, the location management cost is shown to decrease. Numerical examples illustrate such an aspect of the proposed scheme.

진공측정표준의 불확도 평가모델 개발 (Development of Uncertainty Evaluation Model for Vacuum Measurement Standards)

  • 홍승수;임종연;신용현
    • 한국진공학회지
    • /
    • 제20권5호
    • /
    • pp.313-321
    • /
    • 2011
  • 한국표준과학연구원(Korea Research Institute of Standards and Science, KRISS)에는 초음파간섭 수은주압력계(ultrasonic interferometer manometer, UIM), 정적형표준기(static volume expansion system, SVES), 오리피스형 정압표준기(orifice-type dynamic expansion system, ODES) 등 세 개의 주요한 국가 진공표준기가 있다. 이 장치들의 불확도 평가를 위해 각각 변수들의 측정 및 계산 모델을 개발하였다. 국제표준화기구(International Organization for Standardization, ISO) 지침에 따라 표준기들의 확장불확도(expanded uncertainty, U)를 계산하였다.

유연벽면 점탄성 소재의 광대역 동특성 계측 기법 (Measurement Method of Broadband Dynamic Characteristics of Viscoelastic Material for Compliant Coating)

  • 바셀 서우디;안드레이 보이코;전호환;이인원
    • 대한조선학회논문집
    • /
    • 제45권1호
    • /
    • pp.73-80
    • /
    • 2008
  • An improved method to measure the dynamic viscoelastic properties of elastomers is proposed. The method is based on the analysis of forced oscillation of a cylindrical sample loaded with inertial mass. No special equipment or instrumentation other than the ordinary vibration measurement apparatus is required. Typical measurement of the viscoelastic properties of a silicone rubber $Silastic^{(R)}$ S2 were measured over the wide frequency range from 10 Hz to 3 kHz under the action of wide region of deformation from $10^{-4}%$ to 5%. It was shown that modulus of elasticity and loss tangent fall on the single curves when the ratio of load mass to sample mass changed from 1 to 20.

지상레이더의 동적 자세 측정을 통한 추적 정확도 개선 (The Improvement of Tracking Accuracy of the Ground-Based Radar By the Measurement of Dynamic Attitude)

  • 김완규
    • 한국항공우주학회지
    • /
    • 제39권8호
    • /
    • pp.766-773
    • /
    • 2011
  • 항공기용, 함정용 레이더에 비해 비교적 정적인 지상 레이더의 운용 환경을 고려하면 정적인 환경에서 경사면을 측정하는 경사계 등에 사용되는 가속도계로 레이더의 정적인 자세각을 측정할 수 있지만, 바람 및 돌풍 또는 회전하는 안테나의 원심력 등에 의해 동적인 움직임이 발생하게 되는 경우 각가속도가 발생하여 자세각 측정에 오차가 발생할 수 있다. 본 논문에서는 위와 같이 발생한 자세각 측정 오차와 표적 위치에 따른 추적 오차에 대해 분석하고, 가속도계만을 사용한 동적 자세각 측정방법을 제시하고 이에 따라 개선된 추적오차를 시뮬레이션을 통해 결과를 나타내었다.

Field Measurements of the New CCTV Tower in Beijing

  • Xu, Y.L.;Zhan, S.;Xia, H.;Xia, Y.;Zhang, N.
    • 국제초고층학회논문집
    • /
    • 제2권3호
    • /
    • pp.171-178
    • /
    • 2013
  • The emergence of a growing number of tall buildings, often with unusual shapes and innovative structural systems, has led to the realization of the need for and the importance of field measurements. The new China Central Television (CCTV) Tower in Beijing is one of tall buildings with a highly unusual shape and a complex structural system, requiring field measurements to identify its dynamic characteristics for the subsequent dynamic analysis of the tower under wind excitation, seismic-induced ground motion and traffic-induced ground motion. The structural system and the finite element model of the CCTV Tower are first introduced in this paper. The computed natural frequencies and mode shapes are then presented as a reference for the field measurement. After introducing the arrangement of the ambient vibration measurement, the field measured natural frequencies and damping ratios of the CCTV Tower are presented and the measured natural frequencies are finally compared with the computed ones. It was found that the structural damping ratios of the CCTV Tower are small and the computed natural frequencies are smaller than the measured ones by about 12~17%.

The Construction of Initial Analytical Models Structural Health Monitoring of a Masonry Structure

  • Kim, Seonwoong;Kim, Ji Young;Hwang, In Hwan
    • 국제초고층학회논문집
    • /
    • 제4권3호
    • /
    • pp.191-198
    • /
    • 2015
  • It is important to accurately predict structural responses to external excitations such as typhoons and earthquakes when designing structures for serviceability. One of the key procedures to predict reliable vibration responses is to evaluate accurate structural dynamic properties using finite element (FE) models, which properly represent the realistic behavior of buildings. In the case of historic masonry buildings, structural damage could also be caused by ambient vibrations or impacts. Therefore, the preservation plans of historic buildings for low-level vibrations or impacts should be provided by analyzing structural damages within serviceability levels. For this purpose, it is required to provide FE model construction and response analysis methods verified with field measurement data. In this research, long-term field measurement was performed for a cathedral and its dynamic properties were evaluated using measured data. Then, the model was calibrated based on the measured dynamic properties and an overall construction method for the masonry cathedral was proposed. Using the measured accelerations, the vibrations of the belfry were analyzed using the calibrated FE model and finally, the FE model for the cathedral was verified by comparing the measured accelerations with the modeled results.

중성자 래디오그래피를 이용한 액체금속 유동장 측정 (Measurement of Liquid-Metal Flow with a Dynamic Neutron Radiography)

  • 차재은;사이토
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.63-68
    • /
    • 2011
  • The flow-field of a liquid-metal system is very important for the safety analysis and the design of the steam generator of liquid-metal fast breeder reactor. Dynamic neutron radiography (DNR) is suitable for a visualization and measurement of a liquid metal flow and a two-phase flow in a metallic duct. However, the three dimensional DNR techniques is not enough to obtain the velocity information in the wide channel up to now. In this research, a high speed DNR technique was applied to visualize the heavy liquid-metal flow field in the narrow channel with the HANARO-beam facility. The images were taken with a high frame-rate neutron radiography at 250 fps and analyzed with a Particle Image Velocimetry(PIV) method. The images were compared with the results of the commercial CFX code to study the feasibility of DNR technique for the measuring the heavy liquid-metal flow field. The PIV images could discern the turbulent vortex flow in the two-dimensional narrow channel.

Viscoelastic Properties of Fresh Cement Paste to Study the Flow Behavior

  • Choi, Myoungsung;Park, Kyoungsoo;Oh, Taekeun
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권sup3호
    • /
    • pp.65-74
    • /
    • 2016
  • During concrete pumping, the migration and redistribution of particles occur in a pipe and the lubrication layer that forms between the bulk concrete and the pipe wall is the governing factor determining the flow behavior. In order to identify flow behavior of pumping, in this study, the viscoelastic properties related to the microstructural behavior of a flocculated suspension were examined by using dynamic oscillatory measurements. Cement paste is assumed to be a constituent material of the lubrication layer and ten cases of mixing design are employed by changing the proportions of mineral admixtures. The relationship between the yield stress obtained from the steady shear test and the dynamic modulus resulted from the oscillatory shear measurement was derived and the implications of the correlation are discussed. Moreover, based on the investigation of the viscoelastic properties with oscillatory measurements, the initial behavior of pumped concrete was analyzed systematically.

Real Time Wide Area Voltage Stability Index in the Korean Metropolitan Area

  • Han, Sang-Wook;Lee, Byong-Jun;Kim, Sang-Tae;Moon, Young-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.451-456
    • /
    • 2009
  • Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic voltage stability has become one of the achievements we can obtain from PMUs. It is very important to select the most appropriate method for the Korea Electric Power Corporation (KEPCO) system since there are many voltage stability indices. In this paper, we propose an advanced WAVI (Wide Area Voltage Stability) that is well suited for the purposes of monitoring the dynamic voltage stability of KEPCO's PMU installation plan. The salient features of the proposed index are: i) it uses only PMU measurements without coupling with EMS data; ii) it is computationally unburdened and can be applied to real-time situations. The proposed index is applied to the KEPCO test system and the results show that it successfully predicts voltage instability through comparative studies.