• 제목/요약/키워드: Duty cycle range

검색결과 96건 처리시간 0.025초

Duty Cycle 조정이 가능한 새로운 저전력 시스템 CMOS Voltage-Controlled Oscillator 설계 (New Design of Duty Cycle Controllable CMOS Voltage-Controlled Oscillator for Low Power Systems)

  • 조원;이성철;문규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.605-606
    • /
    • 2006
  • Voltage Controlled Oscillator(VCO) plays an important role in today's communication systems. Especially, a Clock Generator(CG) in phase-locked loop(PLL) is usually realized by the VCO. This paper proposes a new VCO with a controllable duty cycle buffer, that can be adopted in low-power high-speed communication systems. Delay cell of the VCO is implemented with gilbert cell. Frequency dynamic range of the VCO is in the range of approximately $50MHz{\sim}500MHz$. Parameters with N-well CMOS 0.18-um process with 1.8V supply voltage was used for the simulations.

  • PDF

A Bidirectional Three-level DC-DC Converter with a Wide Voltage Conversion Range for Hybrid Energy Source Electric Vehicles

  • Wang, Ping;Zhao, Chendong;Zhang, Yun;Li, Jing;Gao, Yongping
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.334-345
    • /
    • 2017
  • In order to meet the increasing needs of the hybrid energy source system for electric vehicles, which demand bidirectional power flow capability with a wide-voltage-conversion range, a bidirectional three-level DC-DC converter and some control strategies for hybrid energy source electric vehicles are proposed. The proposed topology is synthesized from Buck and Boost three-level DC-DC topologies with a high voltage-gain and non-extreme duty cycles, and the bidirectional operation principle is analyzed. In addition, the inductor current ripple can be effectively reduced within the permitted duty cycle range by the coordinated control between the current fluctuation reduction and the non-extreme duty cycles. Furthermore, benefitting from duty cycle disturbance control, series-connected capacitor voltages can also be well balanced, even with the discrepant rise and fall time of power switches and the somewhat unequal capacitances of series-connected capacitors. Finally, experiment results of the bidirectional operations are given to verify the validity and feasibility of the proposed converter and control strategies. It is shown to be suitable for hybrid energy source electric vehicles.

IEEE 802.15.4 저속 WPAN에서 듀티 사이클과 비콘 추적의 통합 제어 (Joint Control of Duty Cycle and Beacon Tracking in IEEE 802.15.4 LR-WPAN)

  • 박성우
    • 한국전자통신학회논문지
    • /
    • 제11권1호
    • /
    • pp.9-16
    • /
    • 2016
  • IEEE 802.15.4 LR-WPAN에서 대부분의 디바이스는 배터리에 의존해 동작하기 때문에 효율적인 에너지 소비기능을 갖추도록 설계되어야 한다. 본 논문은 LR-WPAN에서 에너지 절약을 위한 두 개의 알고리즘, DDC(Dynamic Duty Cycle)와 DBT(: Dynamic Beacon Tracking)를 제안한다. DDC 알고리즘은 채널 상태에 따라 듀티 사이클을 동적으로 조정한다. DBT 알고리즘은 트래픽 조건에 따라 비콘 트래킹 모드를 적응적으로 제어한다. 또한, DDC와 DBT 알고리즘을 결합함으로써 프레임 전달률과 평균 지연 시간을 만족할 만한 수준으로 유지하면서 광범위한 입력 부하에 대해 효과적으로 에너지를 절약할 수 있다.

A MOSFET's Driver Applied to High-frequency Switching with Wide Range of Duty Cycles

  • Zhang, Zhao;Xie, Shaojun
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1402-1408
    • /
    • 2015
  • A MOSFET's gate driver based on magnetic coupling is investigated. The gate driver can meet the demands in applications for wide range of duty cycles and high frequency. Fully galvanic isolation can be realized, and no auxiliary supply is needed. The driver is insensitive to the leakage inductor of the isolated transformer. No gate resistor is needed to damp the oscillation, and thus the peak output current of the gate driver can be improved. Design of the driving transformer can also be made more flexible, which helps to improve the isolation voltage between the power stage and the control electronics, and aids to enhance the electromagnetic compatibility. The driver's operation principle is analyzed, and the design method for its key parameters is presented. The performance analysis is validated via experiment. The disadvantages of the traditional magnetic coupling and optical coupling have been conquered through the investigated circuit.

주행 사이클을 고려한 IPMSM의 효율 및 출력 밀도 개선으로 경량 전기 자동차의 주행거리 연장 (Range Extension of Light-Duty Electric Vehicle Improving Efficiency and Power Density of IPMSM Considering Driving Cycle)

  • 김동민;정영훈;임명섭;심재한;홍정표
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2197-2210
    • /
    • 2016
  • Recently, the trend of zero emissions has increased in automotive engineering because of environmental problems and regulations. Therefore, the development of battery electric vehicles (EVs), hybrid/plug-in hybrid electric vehicles (HEVs/PHEVs), and fuel cell electric vehicles (FCEVs) has been mainstreamed. In particular, for light-duty electric vehicles, improvement in electric motor performance is directly linked to driving range and driving performance. In this paper, using an improved design for the interior permanent magnet synchronous motor (IPMSM), the EV driving range for the light-duty EV was extended. In the electromagnetic design process, a 2D finite element method (FEM) was used. Furthermore, to consider mechanical stress, ANSYS Workbench was adopted. To conduct a vehicle simulation, the vehicle was modeled to include an electric motor model, energy storage model, and regenerative braking. From these results, using the advanced vehicle simulator (ADVISOR) based on MATLAB Simulink, a vehicle simulation was performed, and the effects of the improved design were described.

직류 직권 전동기 제어를 위한 싸이리스터 쵸퍼회러의 설계및 시작 (Design and implementation of thyristor chopper circuit for D.C series motor control)

  • 이윤종;백수현;이성백
    • 전기의세계
    • /
    • 제28권9호
    • /
    • pp.51-59
    • /
    • 1979
  • The forming and design method of D.C thyristor chopper circuit for DC Series motor control is suggested, ard the computation method of thyristor commutaing element's, value which makes it all the more important, is possible. Also the trigger circuit was dealt with. In this paper, in order to control the duty cycle, the duty time is kept on constancy and variable chopping frequency was adopted. By above mentioned circuit design method, the D.C thyristor chopper circuit was implemented and tested. In this circuit, the result of D.C motor control was good and reliable. The relation between the $K_{d}$ and the ratio of input-output current, or the characteristic of speed was varied lineary at the range 0.1 ~ 0.9 of duty cycle. This confirms the fact that D.C to D.C power conversion which is the merit of chopper control is operated most likely a transformer.ormer.

  • PDF

On Teaching Switched Mode Power Supplies - A Converter with Limited Duty Cycle

  • Himmelstoss, Felix A.
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.667-672
    • /
    • 2010
  • A way how to teach a general understanding of switched mode power supplies (SMPS) is shown. A fourth order PWM DC-to-DC converter with limited duty cycle range is treated as an example and a survey over important data (maximum voltage and current ratings for the elements, rms- values for the semiconductor devices and a rough approximation of the losses) of the circuit is given. Furthermore, a converter model based on duty ratio averaging is established. Continuous mode of operation is used. The results make it possible to estimate the applicability of the given converter structure and offer sufficient material for the calculation, design, and analysis and give a better insight into switched mode energy conversion.

Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

  • Lee, Soo Yong;Lim, Sangwook;Ma, Sun Young;Yu, Jesang
    • Radiation Oncology Journal
    • /
    • 제35권3호
    • /
    • pp.274-280
    • /
    • 2017
  • Purpose: To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. Materials and Methods: We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%-60%, 30%-70%, and 0%-90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. Results: The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. Conclusion: As narrow as possible duty cycle such as 40%-60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.

급속충전기용 파워 모듈을 위한 단일단 AC-DC 컨버터 (A Single-Stage AC-DC Power Module Converter for Fast-Charger)

  • 레덧탕;최세완
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.384-390
    • /
    • 2022
  • In this study, a single-stage, four-phase, interleaved, totem-pole AC-DC converter is proposed for a super-fast charger station that requires high power, a wide voltage range, and bidirectional operation capabilities and adopts various types of electric transport vehicles. The proposed topology is based on current-fed push-pull dual active bridge converter combined with the totem-pole operation. Owing to the four-phase interleaving effect, the bridge on the grid side can switch at 0.25, 0.5, and 0.75 to achieve a ripple-free grid current. The input filter can be removed theoretically. Switching methods for the duty of the secondary-side duty cycle are proposed, and they correspond to the primary duty cycle for reducing the circulating power and handling the total harmonic distortion. Therefore, the converter can operate under a wide voltage range. Experimental results from a 7.5 kW prototype are used to validate the proposed concept.

액체 질소의 흐름 조절을 통한 저온 정밀 온도 제어 (Precise Temperature Control by Adjusting Flow of Liquid Nitrogen)

  • 양인석;이지호
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.65-70
    • /
    • 2016
  • We devised a method to control the temperature of a liquid bath as low as $-100^{\circ}C$ using the duty cycle control of a solenoid valve. The solenoid valve controls the flow of liquid nitrogen that we used as a cryogen in this system. By controlling the duty cycle of a solenoid valve using feedback from the measured temperature of the liquid bath, we were able to achieve temperature stability within ${\pm}19mK$ around $-100^{\circ}C$. We also demonstrated that by taking average values of the temperature readings for sequence of measurements from more than one thermometer, it is possible to use this system for the calibration of thermometers within 3 mK. This system and the control method can be used for the precise temperature control in the range between $0^{\circ}C$ and $-100^{\circ}C$, where commercially available precision baths are much expensive and hard to be built in customized configurations.