• Title/Summary/Keyword: Duct Cleaning

Search Result 11, Processing Time 0.025 seconds

Development of a Duct Cleaning Robot and Technology Trends for Subway Stations (지하역사 덕트 청소로봇 기술동향 및 개발)

  • Jeong, Woo-Tae;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1335-1341
    • /
    • 2011
  • Conserving clean air and removing contaminants and particular matters accumulated in the ventilation system of the subway stations are key issue for green railway environment. There is no national guideline or industrial regulations to sustain clean duct and ventilation system, which requires rapid reformation of cleaning procedure and system. In fact, accumulated various particular matters and dusts can occur secondary air contamination and become a primary health harm factor for subway passengers. This study investigates various duct cleaning technologies and trends. In additon, effective cleaning method with an automated robot device is proposed. In particular, current dust cleaning technologies and duct cleaning robots are analyzed based on their functions and feasibilities. The proposed design of automated device is expected to save the operating cost of subway HVAC system and sustain clean air environment.

  • PDF

Development of a CNN-based Cross Point Detection Algorithm for an Air Duct Cleaning Robot (CNN 기반 공조 덕트 청소 로봇의 교차점 검출 알고리듬 개발)

  • Yi, Sarang;Noh, Eunsol;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.1-8
    • /
    • 2020
  • Air ducts installed for ventilation inside buildings accumulate contaminants during their service life. Robots are installed to clean the air duct at low cost, but they are still not fully automated and depend on manpower. In this study, an intersection detection algorithm for autonomous driving was applied to an air duct cleaning robot. Autonomous driving of the robot was achieved by calculating the distance and angle between the extracted point and the center point through the intersection detection algorithm from the camera image mounted on the robot. The training data consisted of CAD images of the duct interior as well as the cross-point coordinates and angles between the two boundary lines. The deep learning-based CNN model was applied as a detection algorithm. For training, the cross-point coordinates were obtained from CAD images. The accuracy was determined based on the differences in the actual and predicted areas and distances. A cleaning robot prototype was designed, consisting of a frame, a Raspberry Pi computer, a control unit and a drive unit. The algorithm was validated by video imagery of the robot in operation. The algorithm can be applied to vehicles operating in similar environments.

Mechanism Design and Control Technique of Duct Cleaning Robot with Self-position Recognition (자기위치 인식 가능한 덕트 청소로봇의 메카니즘 설계 및 제어기법)

  • Jang, Woojin;Seo, Myungin;Ha, Junhwan;Park, Kyongtae;Kim, Dong-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.85-95
    • /
    • 2019
  • This work shows how to design a robot structure and to control to overcome obstacles while traveling through ducts of various diameters and shapes by three-legged robot. Circuits are centered in the body to connect the three wheel bodies that are driven around the center body with the 4-section slider link structure. Also, the springs are used to contract and expand the robot legs so that it can be caparable of various environments. Geared motor, spring, and belt were selected based on the static and dynamic calculation to be suitable to horizontal and vertical travels. The center body is equipped with a camera and the distance sensors, and a control algorithms are implemented so that it can be successfully performed in L-type and T-type ducts. Using UWB modules and trilateration algorithm, the location of the duct-cleaning robot inside the duct could be identified successfully.

Exposure Assessment of Crystalline Silica in Diatomite Powder Handling Workplace with Acute Silicosis (급성 규폐증이 발생한 규조토 분말 취급 작업장의 결정형 실리카 노출평가: 역학조사 사례)

  • Kim, Boowook;Kim, Daeho;Kim, Hyoung-Ryoul;Choi, Byung-Soon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.271-277
    • /
    • 2019
  • Objectives: A 46-year-old woman who had worked on cleaning stainless steel containers with Initially unknown powders died from acute silicosis. To determine whether the acute silicosis was related to his work environment, we conducted exposure assessment the level of exposure to respirable crystalline silica(RCS) during cleaning stainless steel containers with unknown powders. Methods: The exposure assessment of RCS were undertaken according to the National Institute for Occupational Safety and Health(NIOSH) method 7500. The components of the unknown powder were analyzed using X-ray Diffraction. Results: The unknown powder was found to be natural diatomaceous earth, which contained 12% and 9% quartz and cristobalite, respectively, crystalline silica. In the case of cleaning stainless steel containers with diatomaceous earth powder, the primary measurement resulted in 1.3 times higher occupational exposure limit of MOEL(in sum of quartz and cristobalite concentration) and 3.9 times higher in secondary measurement. The workbench was equipped with a local exhaust system, but because there was no hood at the end of the duct, the wind speed at the opening of the duct was 12 m/sec, whereas the controlled wind speed at the working position was only 0.3 m/sec below the legal standard. Conclusions: There is an urgent need to install the hood, conduct safety and health education for employers and workers, and periodically monitoring and manage the working environment.

Design of the Full-Scale Fire Safety Evaluation Facility for Railroad Vehicle Fire (철도차량 실대형 화재안전 성능평가 장치 설계)

  • Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.222-225
    • /
    • 2008
  • To prove a lot of technical difficulties related to the safety management of a railroad fire effectively, we design for the full-scale fire test facility of the railroad vehicle. It will be consist of major 3 part - duct system with smoke cleaning system, measuring section and gas analysis system. The CFD simulation was also carried out to design of the hood and duct system optimization. The results will be help for basic research of the railroad fire safety.

  • PDF

IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function (아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가)

  • Yee Jurng Jae;Lee Joong Hoon;Lee Seung Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

Study of Pressure and Flow in the Air-Cleaner of Commercial Vehicle (디젤엔진의 공기청정기내 압력 및 유동분포에 관한 연구)

  • 류명석;구영곤;김경훈;맹주성
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.47-53
    • /
    • 1997
  • The importance of intake system can not be overstressed in the recent heavy duty commercial vehicle design. The basic requirements of intake system are to have less flow resistance and better air cleaning performance which have direct effects on the performance and service life of engine. In order to improve the performance of engine intake system, the flow phenomena in the intake system should be fully understood. With readily availble CFD code, the numerical analysis becomes the more reliable tools for flow optimization in recent design work. In this research, flow field in the intake system was analyzed by STAR-CD, the 3-D computational fluid dynamics code. Especially, the flow inside of air cleaner was thoroughly analyzed. Pressure distribution and velocity profile in the air cleaner and intake duct was obtained. Having the dust seperated from incoming air at the expense of less pressure drop is the ultimate goal for the research.

  • PDF

A Study on the Operational Variables of the UV-TiO$_2$ Based Photocatalytic Air Cleaning System (UV-TiO$_2$ 광촉매 기반의 공기 정화 시스템의 운전조건에 대한 연구)

  • Han, Chang-Seok;Chang, Hyuk-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.293-301
    • /
    • 2008
  • A study on the operational variables of the UV-TiO$_2$ based photocatalytic air cleaning system was tried. In this study, to examine effects as various air cleaning system conditions, a duct-type reactor was made, and TiO$_2$ was immobilized on a stainless mesh. Benzene was chosen as a target compound. Removal experiments for benzene were done under different initial benzene concentration, air velocity, TiO$_2$ loading, area coated TiO$_2$ as the same TiO$_2$ loading, and UV light intensity conditions. During the experiments, relative humidity was 55%, and reactor temperature was 45$^{\circ}C$. As a result, the photocatalytic degradation of benzene decreased as the inlet concentration increased. But the photocatalytic degradation increased as the concentration boundary layer thickness, amount of TiO$_2$, area coated TiO$_2$ as the same amount of TiO$_2$, and UV light intensity increased. Based on results of current study, they can be applied to the design of air cleaning system over low level VOCs in the indoor air.