• 제목/요약/키워드: Dual Field

검색결과 637건 처리시간 0.025초

Hierarchical WSN Dual-hop Routing Protocol for Improvement of Energy Consumption

  • Park, SeaYoung;LEE, WooSuk;Kwon, Oh Seok;Jung, KyeDong;Lee, Jong-Yong
    • International journal of advanced smart convergence
    • /
    • 제5권2호
    • /
    • pp.24-37
    • /
    • 2016
  • This paper proposes to increase the efficiency of energy in nodes, which rapidly drops during the transmission of the Low Energy Adaptive Clustering Hierarchy (LEACH), through the use of dual-hop layered application in the sensor field. Along with introducing the dual-hop method in the data transmission, the proposed single-hop method for short-range transmission and multi-hop transmission method between the cluster heads for remote transmission were also introduced. Additionally, by introducing a partial multi-hop method in the data transmission, a single-hop method for short range transmission method between the cluster heads for remote transmission was used. In the proposed DL-LEACH, the energy consumption of the cluster head for remote transmission reduced, as well as increased the energy efficiency of the sensor node by reducing the transmission distance and simplifying the transmission route for short-range transmission. As compared the general LEACH, it was adapted to a wider sensor field.

초음속 이중 동축 제트유동에서 발생하는 충격파 구조에 관한 연구 (Study of the Shock Structure of Supersonic, Dual, Coaxial, Jets)

  • 이권희;이준희;김희동;박종호
    • 한국추진공학회지
    • /
    • 제5권4호
    • /
    • pp.94-101
    • /
    • 2001
  • 본 연구에서는 이중 동축 노즐로부터 대기로 방출되는 초음속 자유제트유동을 실험하였다. 출구마하수, 보조제트 충돌각 및 주제트 노즐 형상이 다른 8종류의 노즐을 사용하고, 주제트 및 보조제트 압력비를 각각 1.0∼10.0, 1.0∼4.0으로 변화시켜 노즐 출구 근방에서의 자유제트 유동장 특성을 상세히 조사하였다. 본 연구의 결과로부터 노즐의 형상 및 보조제트 분류각이 노즐 출구의 충격과 시스템에 영향을 미치며, 노즐출구로부터 마하디스크까지의 거리는 주제트 압력비가 증가할수록, 보조제트 압력비가 감소할수록 증가하나 마하디스크의 직경은 주제트 및 보조제트 압력비의 조합에 따라 달라진다는 것을 알았다.

  • PDF

The Electrical Properties of Single-silicon TFT Structure with Symmetric Dual-Gate for kink effect suppression

  • 이덕진;강이구
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권5호
    • /
    • pp.783-790
    • /
    • 2005
  • In this paper, we have simulated a Symmetric Dual-gate Single-Si TFT which has three split floating n+ zones. This structure reduces the kink-effect drastically and improves the on-current. Due to the separated floating n+ zones, the transistor channel region is split into four zones with different lengths defined by a floating n+ region, This structure allows an effective reduction of the kink-effect depending on the length of two sub-channels. The on-current of the proposed dual-gate structure is 0.9mA while that of the conventional dual-gate structure is 0.5mA at a 12V drain voltage and a 7V gate voltage. This result shows a 80% enhancement in on-current. Moreover we observed the reduction of electric field in the channel region compared to conventional single-gate TFT and the reduction of the output conductance in the saturation region. In addition, we also confirmed the reduction of hole concentration in the channel region so that the kink-effect reduces effectively.

  • PDF

2D Transconductance to Drain Current Ratio Modeling of Dual Material Surrounding Gate Nanoscale SOl MOSFETs

  • Balamurugan, N.B.;Sankaranarayanan, K.;John, M.Fathima
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권2호
    • /
    • pp.110-116
    • /
    • 2009
  • The prominent advantages of Dual Material Surrounding Gate (DMSG) MOSFETs are higher speed, higher current drive, lower power consumption, enhanced short channel immunity and increased packing density, thus promising new opportunities for scaling and advanced design. In this Paper, we present Transconductance-to-drain current ratio and electric field distribution model for dual material surrounding gate (DMSGTs) MOSFETs. Transconductance-to-drain current ratio is a better criterion to access the performance of a device than the transconductance. This proposed model offers the basic designing guidance for dual material surrounding gate MOSFETs.

YANG-MILLS OR YANG-MILLS-HIGGS FIELDS OVER KAEHLER AND CONTACT MANIFOLDS

  • Park, Young-Soo;Suh, Young-Jin
    • 대한수학회보
    • /
    • 제40권1호
    • /
    • pp.109-122
    • /
    • 2003
  • In this paper we give a characterization of an irreducible connection with harmonic curvature over a connected Kaehler manifold to be self-dual. Also we introduce new notions of $c_{i}-self-dual$ or Kaehler Yang-Mills connections on compact Kaehler manifolds and investigate some fundamental properties of this kind of new connections. Moreover, on a compact odd dimensional Riemannian manifold we give a property of generalized monopole.

이중충격파형 충격시험장비를 이용한 충격시험 결과 및 분석 (The Shock-Test Result and Analysis Using Dual-Pulse Shock Testing Machine)

  • 배종수
    • 한국군사과학기술학회지
    • /
    • 제21권3호
    • /
    • pp.342-348
    • /
    • 2018
  • The important issue of equipment installed in maritime weapon system is shock survivability against underwater explosion(UNDEX). If the shock survivability of equipment should not be guaranteed, the successful mission also could not be achieved. For that reason, the shock-resistance of each equipment under UNDEX environment should be demonstrated before deployment at combat field. However, the actual UNDEX test on the ocean is too expensive to conduct. Also, it has diverse dangerous factors. The main characteristic of UNDEX is a dual-pulse shock. The vertical shock test machine able to simulate dual pulse shock signal on the ground will be introduced in this paper. The dual-pulse shock signal presented in certain shock standard was achieved with this shock-test machine on the ground. The analytical procedure to set a test condition was verified by comparing simulation result with experiment result.

AN ALTERED GROUP RING CONSTRUCTION OF THE [24, 12, 8] AND [48, 24, 12] TYPE II LINEAR BLOCK CODE

  • Shefali Gupta;Dinesh Udar
    • 대한수학회보
    • /
    • 제60권3호
    • /
    • pp.829-844
    • /
    • 2023
  • In this paper, we present a new construction for self-dual codes that uses the concept of double bordered construction, group rings, and reverse circulant matrices. Using groups of orders 2, 3, 4, and 5, and by applying the construction over the binary field and the ring F2 + uF2, we obtain extremal binary self-dual codes of various lengths: 12, 16, 20, 24, 32, 40, and 48. In particular, we show the significance of this new construction by constructing the unique Extended Binary Golay Code [24, 12, 8] and the unique Extended Quadratic Residue [48, 24, 12] Type II linear block code. Moreover, we strengthen the existing relationship between units and non-units with the self-dual codes presented in [10] by limiting the conditions given in the corollary. Additionally, we establish a relationship between idempotent and self-dual codes, which is done for the first time in the literature.

모델연소기에서의 분사기와 선회기의 영향 (The Effects of Injector and Swirler on the Flame Stability in a Model Combustor)

  • 박승훈;이동훈;배충식
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1998년도 제17회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.9-21
    • /
    • 1998
  • The optimization of frontal device including fuel nozzle and swirler is required to secure the mixing of fuel and air, and the combustion stability in the gas turbine combustor design for the reduction of pollutant emissions and the increase of combustion efficiency. The effects of injection nozzle and swirler on the flow field, spray characteristics and consequently the combustion stability, were experimentally investigated by measuring the velocity field, droplet sizes of fuel spray, lean combustion limit and the temperature field in the main combustion region. The effect of fuel injection nozzle was tested by adopting three different nozzles; a dual orifice fuel nozzle, a hollow cone nozzle and a solid cone nozzle. These tests were combined with the three different swirler geometries; a dual-stage swirler with 40$^{\circ}$ /-4 5$^{\circ}$ vanes and two single-stage swirlers with 40$^{\circ}$ vane angle having 12 and 16vanes, respectively. Flow fields and spray characteristics were measured with APV(Adaptive Phase Doppler Velocimetry) under atmospheric condition using kerosine fuel. Temperatures were measured by Pt-PtI3%Rh, R-type thermocouple which was 0.2mm thick. It was found that the dual swirler resulted in the biggest recirculation zone with the highest reverse flow velocity at the central region, which lead the most stable combustion. The various combustion characteristics were observed as a function of the combination between the injector and swirler, that gave a tip for the better design of gas turbine combustor.

  • PDF

Dual effect of Low- frequency Electromagnetic Field on Muscle Histopathology of Caspian Sea Cyprinus carpio

  • Samiee, Farzaneh;Samiee, Keivandokht
    • 한국어병학회지
    • /
    • 제30권1호
    • /
    • pp.51-61
    • /
    • 2017
  • The effect of electromagnetic field on aquatic organisms has received little attention. In the current study, the effect of 50Hz electromagnetic field on muscle histopathology of Caspian Sea Cyprinus carpio, a species of economic importance, was investigated. A total of 120 healthy fish were used in this study. They were classified randomly in one of two groups as follows: Control or unexposed EMF group and experimental group with 5 different magnetic field intensities (0.1, 1, 3, 5 and 7mT) at 2 different exposure times including 30 and 60 minutes. Fish in the experimental group were exposed only once. Two weeks after exposure, dorsal muscles sectioned transversely, stained and were examined using a light microscope. Histopathologic assessments showed significant difference between control and EMF exposed groups at both 30 min. (p<0.01) and 60 min. (p<0.001) exposure times. We report for the first time that electromagnetic field in interaction with muscular tissue of Cyprinus carpio exhibits a dual effect which depends on the field intensity, and exposure time. At short exposure time (30 min.), EMF stimulates muscle growth process. At longer exposure time (60 min.), EMF can damage muscle tissue and result in muscle necrosis. More research is required to elucidate precise mechanisms involved in muscle hypertrophy and pathologic changes.

상부와 하부 IrMn층을 갖는 단일구조 및 이중구조 거대자기저항-스핀밸브 다층박막의 자기적 특성 비교 분석 (Magnetoresistance of Single-type and Dual-type GMR-SV Multilayer Thin Films with Top and Bottom IrMn Layer)

  • 최종구;김수희;최상헌;이상석
    • 한국자기학회지
    • /
    • 제27권4호
    • /
    • pp.115-122
    • /
    • 2017
  • 반강자성체인 IrMn 박막이 삽입된 4가지 다른 유형으로 GMR-SV 다층박막을 Corning glass 위에 이온빔 증착 시스템과 DC 마그네트론 스퍼터링 시스템으로 제조하였다. 모든 박막시료는 진공 열처리 후 측정한 major 및 minor 자기저항(MR) 곡선으로부터 자기적 특성을 조사하였다. IrMn 박막이 삽입된 상부층의 이중구조(dual-type structure) GMR-SV 다층박막에서 고정층의 교환결합력($H_{ex}$)과 보자력($H_c$), 자유층의 보자력과 상호교환결합력($H_{int}$)은 각각 410 Oe, 60 Oe, 1.6 Oe, 7.0 Oe이었다. 2개의 자유층에 의한 히스테리시스 곡선은 안정된 사각비를 형성하였으며, 자기저항비(MR(%))는 3.7 %와 5.0 %의 합으로 8.7 %이었다. 그리고 평균 자장민감도(MS)가 2.0 %/Oe을 유지하고 있었다. 반면에 IrMn 박막이 삽입된 하부층의 단일구조와 이중구조 GMR-SV 다층박막의 자기적 특성은 IrMn 박막이 삽입된 상부층의 단일구조와 이중구조 GMR-SV 다층박막보다 훨씬 저하하게 나타내었다. 이중구조 GMR-SV 다층박막의 강자성체인 고정층과 자유층의 자화 스핀배열을 서로 반평행 상태에서 독립적인 이중 스핀 의존산란(Spin-dependent Scattering) 효과에 의해 MR은 최대값을 나타내었다.