• Title/Summary/Keyword: Dry Shrinkage Test

Search Result 53, Processing Time 0.022 seconds

The Analysis of Statistical Behavior in Concrete Creep (콘크리트 크리프의 확률론적 거동 해석)

  • Kim, Doo-Hwan;Park, Jong-Choul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.237-246
    • /
    • 2001
  • This study is to measure the creep coefficient by 3 days, 7 days and 28 days in the age when loading for the quality assessment of $350kgf/cm^2$ in the high-strength concrete. And it is to analyze the behavior of creep coefficient by applying the experimental data though the compressive strength test, the elastic modulus test and the dry shrinkage test to the ACI-209, AASHTO-94 and CEB/FIP-90, the prediction mode, and the basis of concrete structural design. Also it is to analyze the behavior of short-term creep coefficient during 91 days in the age when loading through the experiment by using the regression analysis, the statistical theory. As applying it to the long-term behavior during 365 days and comparing with the creep prediction mode and examining it, the result from the analysis of the quality of the concrete is as follows. As the result of comparison and analysis about the ACI-209, AASHTO-94 and CEB/FIP-90, the prediction mode, and the basis of concrete structural design, the normal Portland cement class 1 shows the approximate value with the prediction of GEE/PIP-90 and the basis of concrete structural design, but in case of the prediction of ACI-209 and AASHTO-94, there would be worry of underestimation in the application.

  • PDF

The Development of Cement Treated Base Material with Restraint Reflection Crack (반사균열을 억제한 시멘트 안정처리 기층 재료개발)

  • Kang, Sung-Cheul;Lee, Kang-Won;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.7 no.2 s.24
    • /
    • pp.33-43
    • /
    • 2005
  • This paper describes a new approach to minimize the amount of shrinkage cracking in cement treated base(CTB). CTB is a stiffness base having lots of merits such as higher rutting resistance, minimizing fatigue cracking, and the ability to distribute upper loads. However, It is not applied to asphalt pavement system in Korea because of possible cracks caused by dry shrinkage. The goal of this study is the development of cement treated base with lower shrinkage for preventing reflection cracks and rutting. After identifying factors affecting dry shrinkage and analyzing mechanism of each admixture, the laboratory and field tests were designed and performed. Through the preliminary tests, the mix design containing 25 percent o( fly ash and 7 percent of cement was suggested. This mix design was satisfied with strength for Korea specification standard. According to the results considering strength, shrinkage, and economical efficiency, two mix designs were selected; 1) containing 25 percent of fly ash and 2) containing 25 percent of fly ash with 10 percent of expensive additive. For field test based on the result of laboratory test, the optimized alternative in cement treated base with lower shrinkage was the mix design containing 25 percent of fly ash with 10 percent of expansive additive.

  • PDF

Effect of Cyclic Moisture Content Changes on Shrinkage and Thermal Conductivity in Domestic Quercus acutissima Carr. and Larix Kaempferi Carr. (국내산 상수리나무와 일본 잎갈나무의 수축율과 열전도율에 대한 주기적인 함수율 변화의 영향)

  • Mun, Sung-Hee;Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.41-50
    • /
    • 2002
  • Small clear specimens of Quercus acutissima Carr. and Larix caempferi Carr. were used to measure shrinkage and thermal conductivity for the reasonable and effective use. All samples were conditioned to 18, 12, 5% moisture contents in a humidity chamber of 86, 66, 20% relative humidity(RH), respectively and room temperature(23℃) All specimens were conducted on the shrinkage and thermal conductivity test at each MCs. These processes(cycle) were repeated three times. The radial and tangential shrinkages of Quercus acutissima Carr. and Larix caempferi Carr. decreased at each level of MCs, with the increasing cycles. The radial and tangential shrinkages increased as the specific gravity(on oven-dry weight and volume basis) increased. Thermal conductivities of the radial and tangential direction of Quercus acutissima Carr. and Larix caempferi Carr. increased at each levels of MCs, with increasing cycles. Good correlations were obtained between shrinkages and thermal conductivities of radial and tangential direction, and specific gravity (on oven-dry weight and oven-dry volume basis) and MC.

Rock wool wastes as a supplementary cementitious material replacement in cement-based composites

  • Lin, Wei-Ting;Cheng, An;Huang, Ran;Wu, Yuan-Chieh;Han, Ta-Yuan
    • Computers and Concrete
    • /
    • v.11 no.2
    • /
    • pp.93-104
    • /
    • 2013
  • The use of rock wool waste, an industrial by-product, in cement-based composites has positive effects on the environment because it reduces the problems associated rock wool disposal. The experiments in this study tested cement-based composites using various rock wool waste contents (10, 20, 30 and 40% by weight of cement) as a partial replacement for Portland cement in mortars. The pozzolanic strength activity test, flow test, compressive strength test, dry shrinkage test, absorption test, initial surface absorption test and scanning electron microscope observations were conducted to evaluate the properties of cement-based composites. Test results demonstrate that the pozzolanic strength activity index for rock wool waste specimens is 103% after 91 days. The inclusion of rock wool waste in cement-based composites decreases its dry shrinkage and initial surface absorption, and increases its compressive strength. These improved properties are the result of the dense structure achieved by the filling effect and pozzolanic reactions of the rock wool waste. The addition of 30% and 10% rock wool wastes to cement is the optimal amount based on the results of compressive strength and initial surface absorption for a w/cm of 0.35 and 0.55, respectively. Therefore, it is feasible to utilize rock wool waste as a partial replacement of cement in cement-based composites.

Mock-up Test on Concrete added Admixture for Reducing the Dry Shrinkage (건조수축 저감제를 혼입한 콘크리트의 Mock-up test)

  • Park, Heung-Lee;Lee, Jong-Rok;Choi, Myung-Hwa;Park, He-Gon;Song, In-Myung;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.773-776
    • /
    • 2008
  • Restraining cracks on concrete structures can be the basic condition to improve the durability, so in this research, the resistibility on the drying shrinkage of concrete structures in the long period was being confirmed and as the reason of this shrinkage, the density of minute textures was being analyzed using a wooden prototype of a full scale produced with ready-mixed concrete and agents of glycol which can be used as a surfactant. As result of those tests, PFB technology can reduce the drying shrinkage by approximately $-100{\sim}200{\times}10^{-6}$ on a wooden prototype of a full scale and can also reduce the pore volume as the obstruction to the movement of gas or liquid by approximately $2.4{\sim}3.5$% so that PFB technology can be used to assure the resistibility on the drying shrinkage.

  • PDF

Properties and Prediction Model for Ultra High Performance Fiber Reinforced Concrete (UHPFRC): (I) Evaluation of Setting and Shrinkage Characteristics and Tensile Behavior (초고성능 섬유보강 콘크리트(UHPFRC)의 재료 특성 및 예측모델: (I) 응결 및 수축 특성과 인장거동 평가)

  • Yoo, Doo-Yeol;Park, Jung-Jun;Kim, Sung-Wook;Yoon, Young-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.307-315
    • /
    • 2012
  • Recently, ultra high performance fiber reinforced concrete (UHPFRC) having over 180 MPa compressive strength and 10 MPa tensile strength has been developed in Korea. However, UHPFRC represents different material properties with normal concrete (NC) and conventional high performance concrete (HPC) such as a high early age autogenous shrinkage and a rapid dry on the surface, because it has a low water-binder ratio and high fineness admixtures without coarse aggregate. In this study, therefore, to propose suitable experimental methods and regulations, and to evaluate mechanical properties at a very early age for UHPFRC, setting, shrinkage and tensile tests were performed. From the setting test results, paraffin oil was an appropriate material to prevent drying effect on the surface, because if paraffin oil is applied on the surface, it can efficiently prevent the drying effect and does not disturb or catalyze the hydration of cement. From the ring-test results, it was defined that the shrinkage stress is generated at the time when the graph tendency of temperature and strain of inner steel ring is changed. By comparing with setting test result, the shrinkage stress was firstly occurred as the penetration resistance of 1.5 MPa was obtained, and it was about 0.6 and 2.1 hour faster than those of initial and final sets. So, the starting time of autogenous shrinkage measurement (time-zero) of UHPFRC was determined when the penetration resistance of 1.5 MPa was obtained. Finally, the tensile strength and elastic modulus of UHPFRC were measured from near initial setting time by using a very early age tensile test apparatus, and the prediction models for tensile strength and elastic modulus were proposed.

An Experimental Study on Early Strength and Drying Shrinkage of High Strength Concrete Using High Volumes of Ground Granulated Blast-furnace Slag(GGBS) (고로슬래그 미분말을 대량 사용한 고강도 콘크리트의 조기강도 및 길이변화 특성에 관한 실험적 연구)

  • Yang, Wan-Hee;Ryu, Dong-Woo;Kim, Woo-Jae;Park, Dong-Cheol;Seo, Chee-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.4
    • /
    • pp.391-399
    • /
    • 2013
  • For high strength concrete of 40~60 MPa, the effects on the early strength and concrete dry shrinkage properties replacing 60~80% of Ordinary Portland Cement with Blast Furnace Slag Powder and using the Alkali Activator (Modified Alkali Sulfate type) are considered in this study. 1% Alkali Activator to the binder, cumulative heat of hydration for 72 hours was increased approximately 45%, indicating that heat of hydration contributes to the early strength of concrete, and the slump flow of concrete decreased slightly by 3.7~6.6%, and the 3- and 7- strength was increased by 8~12%, which that the Alkali Activator (Modified Alkali Sulfate type) is effective for ensuring the early strength when manufacturing High Strength Concrete (60%) of Blast Furnace Slag Powder. Furthermore, the dry shrinkage test, both 40 MPa and 60 MPa specimens had level of length changes in order of BS40 > BS60 > BS60A > BS80A, and the use of the Alkali Activator somewhat improved resistance to dry shrinkage.

Investigation on Properties of Concrete with Crushed Sand on Site (부순모래를 사용한 콘크리트의 현장 품질 특성에 관한 실험 연구)

  • Lee, Sung-Bok;Lee, Do-Heon;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.3
    • /
    • pp.107-112
    • /
    • 2003
  • This study is to investigate the properties of concrete with crushed sand on site and to propose a quality guideline for its use as artificial sand and concrete. From our experimental result in laboratory and site, we found that demand water of concrete with crushed sand for target slump increased by 18kg/m3 compared to mixed sand and l8kg/m3 compared to sea sand respectively. The compressive strength increased by around 3∼6% when compared to concrete with sea sand. Accordingly, our study showed that the combined sand mixed with sea sand would be desirable to obtain workability and strength of concrete including dry shrinkage and bleeding test. Furthermore, the optimal replacement percentage of crushed sand was 50% with sea sand. As such, crushed sand would be sufficient as fine aggregate for concrete in terms of economic efficiency and quality. Crushed sand, on the other hand can only be used as fine aggregate when VFS(Very Fine Sand) is below 3.5 percentage of weight of sand and particle shape is above 55 percentage. Also, the particle shape and microsand passing NO.200 sieve should continually be improved to increase workability of concrete on site.

The Characteristics of the Change in dry Contraction Length of Dry Mortar for Each Cosmetic Period using an Improved Durometer (개량형 Durometer를 활용한 미장시기별 Dry Mortar의 건조수축 길이변화 특성)

  • Han, Soo-Hwan;Hyun, Seung-Yong;Hwang, Yin-seung;Yoon, Chi-Whan;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.190-191
    • /
    • 2021
  • This study is conducted to provide a method to estimate the setting time and early age compressive strength using D type durometer.Test results indicated that the use of D type Durometer attached with modified needle, which was designed to secure improved accuracy in setting and compressive strength, enables to estimate setting time and the compressive strength at early age.

  • PDF

Effect of water storage on flexural strength of silorane and methacrylate-based composite resins

  • Panahandeh, Narges;Torabzadeh, Hassan;Naderi, Hani;Sheikh-Al-Eslamian, Seyedeh Mahsa
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.309-315
    • /
    • 2017
  • Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens ($2{\times}2{\times}25mm$) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.