• Title/Summary/Keyword: Drain engineering

Search Result 987, Processing Time 0.033 seconds

DC and RF Characteristics of 100-nm mHEMT Devices Fabricated with a Two-Step Gate Recess (2단계 게이트 리세스 방법으로 제작한 100 nm mHEMT 소자의 DC 및 RF 특성)

  • Yoon, Hyung Sup;Min, Byoung-Gue;Chang, Sung-Jae;Jung, Hyun-Wook;Lee, Jong Min;Kim, Seong-Il;Chang, Woo-Jin;Kang, Dong Min;Lim, Jong Won;Kim, Wansik;Jung, Jooyong;Kim, Jongpil;Seo, Mihui;Kim, Sosu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.282-285
    • /
    • 2019
  • A 100-nm gate-length metamorphic high electron mobility transistor(mHEMT) with a T-shaped gate was fabricated using a two-step gate recess and characterized for DC and microwave performance. The mHEMT device exhibited DC output characteristics having drain current($I_{dss}$), an extrinsic transconductance($g_m$) of 1,090 mS/mm and a threshold voltage($V_{th}$) of -0.65 V. The $f_T$ and $f_{max}$ obtained for the 100-nm mHEMT device were 190 and 260 GHz, respectively. The developed mHEMT will be applied in fabricating W-band monolithic microwave integrated circuits(MMICs).

Retrospective analysis of the urban inundation and the impact assessment of the flood barrier using H12 model (H12 모형을 이용한 도시침수원인 및 침수방어벽의 효과 분석)

  • Kim, Bomi;Noh, Seong Jin;Lee, Seungsoo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.5
    • /
    • pp.345-356
    • /
    • 2022
  • A severe flooding occured at a small urban catchment in Daejeon-si South Korea on July 30, 2020 causing significant loss of property (inundated 78 vehicles and two apartments) and life (one casualty and 56 victims). In this study, a retrospective analysis of the inundation event was implemented using a physically-based urban flood model, H12 with high-resolution data. H12 is an integrated 1-dimensional sewer network and 2-dimensional surface flow model supported by hybrid parallel techniques to efficiently deal with high-resolution data. In addition, we evaluated the impact of the flooding barriers which were installed after the flood disaster. As a result, it was found that the inundation was affected by a combination of multiple components including the shape of the basin, the low terrain of the inundation area located in the downstream part of the basin, and lack of pipe capacity to drain discharge from the upstream during heavy rain. The impact of the flooding barriers was analyzed by modeling with and without barriers on the high-resolution terrain input data. It was evaluated that the flood barriers effectively lower the water depth in the apartment complex. This study demonstrates capability of high-resolution physically-based urban modeling to quantitatively assess the past inundation event and the impact of the reduction measures.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Advanced Hybrid EER Transmitter for WCDMA Application Using Efficiency Optimized Power Amplifier and Modified Bias Modulator (효율이 특화된 전력 증폭기와 개선된 바이어스 모듈레이터로 구성되는 진보된 WCDMA용 하이브리드 포락선 제거 및 복원 전력 송신기)

  • Kim, Il-Du;Woo, Young-Yun;Hong, Sung-Chul;Kim, Jang-Heon;Moon, Jung-Hwan;Jun, Myoung-Su;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.880-886
    • /
    • 2007
  • We have proposed a new "hybrid" envelope elimination and restoration(EER) transmitter architecture using an efficiency optimized power amplifier(PA) and modified bias modulator. The efficiency of the PA at the average drain voltage is very important for the overall transmitter efficiency because the PA operates mostly at the average power region of the modulation signal. Accordingly, the efficiency of the PA has been optimized at the region. Besides, the bias modulator has been accompanied with the emitter follower for the minimization of memory effect. A saturation amplifier, class $F^{-1}$ is built using a 5-W PEP LDMOSFET for forward-link single-carrier wideband code-division multiple-access(WCDMA) at 1-GHz. For the interlock experiment, the bias modulator has been built with the efficiency of 64.16% and peak output voltage of 31.8 V. The transmitter with the proposed PA and bias modulator has been achieved an efficiency of 44.19%, an improvement of 8.11%. Besides, the output power is enhanced to 32.33 dBm due to the class F operation and the PAE is 38.28% with ACLRs of -35.9 dBc at 5-MHz offset. These results show that the proposed architecture is a very good candidate for the linear and efficient high power transmitter.

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

Enhanced Device Performance of IZO-based oxide-TFTs with Co-sputtered $HfO_2-Al_2O_3$ Gate Dielectrics (Co-sputtered $HfO_2-Al_2O_3$을 게이트 절연막으로 적용한 IZO 기반 Oxide-TFT 소자의 성능 향상)

  • Son, Hee-Geon;Yang, Jung-Il;Cho, Dong-Kyu;Woo, Sang-Hyun;Lee, Dong-Hee;Yi, Moon-Suk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.6
    • /
    • pp.1-6
    • /
    • 2011
  • A transparent oxide thin film transistors (Transparent Oxide-TFT) have been fabricated by RF magnetron sputtering at room temperature using amorphous indium zinc oxide (a-IZO) as both of active channel and source/drain, gate electrodes and co-sputtered $HfO_2-Al_2O_3$ (HfAIO) as gate dielectric. In spite of its high dielectric constant > 20), $HfO_2$ has some drawbacks including high leakage current and rough surface morphologies originated from small energy band gap (5.31eV) and microcrystalline structure. In this work, the incorporation of $Al_2O_3$ into $HfO_2$ was obtained by co-sputtering of $HfO_2$ and $Al_2O_3$ without any intentional substrate heating and its structural and electrical properties were investigated by x-ray diffraction (XRD), atomic force microscopy (AFM) and spectroscopic ellipsometer (SE) analyses. The XRD studies confirmed that the microcrystalline structures of $HfO_2$ were transformed to amorphous structures of HfAIO. By AFM analysis, HfAIO films (0.490nm) were considerably smoother than $HfO_2$ films (2.979nm) due to their amorphous structure. The energy band gap ($E_g$) deduced by spectroscopic ellipsometer was increased from 5.17eV ($HfO_2$) to 5.42eV (HfAIO). The electrical performances of TFTs which are made of well-controlled active/electrode IZO materials and co-sputtered HfAIO dielectric material, exhibited a field effect mobility of more than $10cm^2/V{\cdot}s$, a threshold voltage of ~2 V, an $I_{on/off}$ ratio of > $10^5$, and a max on-current of > 2 mA.

Characteristics for Consolidation and Shear Strength of Bottom Ash Compaction Pile According to Replacement Ratio in Clay (점토지반에 적용된 저회다짐말뚝의 치환율에 따른 압밀침하특성 및 전단특성)

  • Park, Sehyun;Jee, Sunghyun;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.7
    • /
    • pp.57-63
    • /
    • 2010
  • The necessity of effective and economical improvement for soft ground is required more and more as mountains form 70% of country. The soft ground improvement methods for ocean development are sand compaction pile method, displacement method are applied to the soft ground improvement from ocean development pre-loading method, air pressure method, well point method, pack drain method, quicklime pile method etc. Among them, the sand compaction pile method, has many problems such as the economical problem on importing materials due to the lack of sand and destroying the nature while collecting sand. To replace the sand with other alternative materials, a study on the bottom ash compaction pile method because the bottom ash has the similar engineering properties with sand. Therefore, in this study, after compose the complex soil with a replacement rate of 10~80% and a large direct shear test, shear test, consolidation test with replacement rates of bottom ash are performed to estimate whether its shear and consolidation characteristics are suitable for the alternative material of compaction pile method. As a result of test, Shear Strength Parameters tend to be increased in accordance with the increase of replacement ratio of bottom compaction pile, and Settlement Reduction Factor and $t_{90}$ tend to be decreased.

The Study of a Development Plan of the Industrial Security Expert System (산업보안관리사 자격제도 발전 방안에 대한 고찰)

  • Cho, Yong-Sun
    • Korean Security Journal
    • /
    • no.40
    • /
    • pp.175-207
    • /
    • 2014
  • This paper focuses on the study of a development direction of the industrial security Expert system. First of all, in order to manage Industrial security system, we need to have law, criminology, business and engineering professionals as well as IT experts, which are the multi-dimensional convergence professionals. Secondly, industrial organizations need to have workforce who can perform security strategy; security plan; security training; security services; or security system management and operations. Industrial security certification system can contribute to cultivate above mentioned professional workforce. Currently Industrial Security Expert(ISE) is a private qualification. However, the author argued that it have to be changed to national qualification. In addition, it is necessary that the system should be given credibility with verifying the personnel whether they are proper or not in the their field. In terms of quality innovation, it is also necessary that distinguish the levels of utilization of rating system of the industrial security coordinator through a long-term examination. With respect to grading criteria, we could consider the requirements as following: whether they must hold the degree of the industrial security-related areas of undergraduate or postgraduate (or to be); what or how many industrial security-related courses they should complete through a credit bank system. If the plan of completing certain industrial security-related credits simply through the credit bank system, without establishing a new industrial security-related department, has established, then industrial security study would be spreaded and advanced. For private certification holders, the problem of the qualification succeeding process is important matter. Additionally, it is necessary to introduce the certifying system of ISMS(Industrial Security Management System) which is a specialized system for protecting industrial technology. To sum up, when the industrial security management system links the industrial security management certification, industrial security would realize in the companies and research institutions dealing with national key technology. Then, a group synergy effect would occurs.

  • PDF

An Experimental Study for Drainage Capacity Improvement of Waterway with Steep Slope (급경사 사면 도수로의 배수능력 개선을 위한 실험적 연구)

  • Kim, Jung Soo;Kim, Ju Hyung;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2303-2315
    • /
    • 2013
  • In general, the waterway was installed for drain water from steep slope and waterway cover was set up to prevent overflow and water separation at berm of waterway. In this study, hydraulic experiment was conducted to analyze the flow characteristics and enact standard design criteria of the waterway. Hydraulic experimental apparatus which can change the slope of waterway and the length of berm were installed to analyze of flow characteristics at the waterway. The slopes of waterway were $40^{\circ}$, $50^{\circ}$, $60^{\circ}$, and $70^{\circ}$ and the range of discharge were 1.0~5.6 ${\ell}/s$. The flow in berm was distinguished two types such as hydraulic jump and splash flow. These kinds of flows depended on the rates of discharge in waterway. When inlet discharge was below 1.1~2.0 ${\ell}/s$, the separation phenomenon of water was generated at upper and lower portion in berm by the splash flow. The scattering range of water particles and length of water separation was measured depending on the slope of waterway. The start point of scattering was about 20 cm(1.3B) from the place connected upper waterway with brem and the length of water separation was till 210 cm(3.5B) from the place connected lower waterway with brem. Therefore, the waterway cover needed to install from starting of berm to 1B and from the lower part of berm to 3.5B.

Key Re-distribution Scheme of Dynamic Filtering Utilizing Attack Information for Improving Energy Efficiency in WSNs (무선 센서 네트워크에서 에너지 효율성 향상을 위해 공격정보를 활용한 동적 여과 기법의 키 재분배 기법)

  • Park, Dong-Jin;Cho, Tae-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.2
    • /
    • pp.113-119
    • /
    • 2016
  • Wireless sensor networks are vulnerable to an adversary due to scarce resources and wireless communication. An adversary can compromise a sensor node and launch a variety of attacks such as false report injection attacks. This attack may cause monetary damage resulting in energy drain by forwarding the false reports and false alarms at the base station. In order to address this problem, a number of en-route filtering schemes has been proposed. Notably, a dynamic en-route filtering scheme can save energy by filtering of the false report. In the key dissemination phase of the existing scheme, the nodes closer to the source node may not have matching keys to detect the false report. Therefore, continuous attacks may result in unnecessary energy wastage. In this paper, we propose a key re-distribution scheme to solve this issue. The proposed scheme early detects the false report injection attacks using initially assigned secret keys in the phase of the key pre-distribution. The experimental results demonstrate the validity of our scheme with energy efficiency of up to 26.63% and filtering capacity up to 15.92% as compared to the existing scheme.